register file 0x24 is for control of the DW1000 synchronisation hardware.
There is a separate application note giving details of the external synchronisation. Please consult with
Decawave applications support team for details. The capabilities of the DW1000 with respect to external
synchronisation are described briefly in section
OFFSET in Register 0x24
Mnemonic
Description
0x00
External clock synchronisation counter configuration
0x04
EC_RXTC
External clock counter captured on RMARKER
0x08
EC_GOLP
External clock offset to first path 1 GHz counter
7.2.37.1
Sub-Register 0x24:00 EC_CTRL
ID
Length
(octets)
Type
Mnemonic
Description
24:00
4
RW
EC_CTRL
External clock synchronisation counter configuration
Register file: 0x24 – External Synchronisation Control
, sub-register 0x00 is the External clock synchronisation
counter configuration register, EC_CTRL. The EC_CTRL register is used to configure the external
synchronisation mode. The EC_CTRL register contains the following sub-fields:
REG:24:00 –EC_CTRL– External clock synchronisation counter configuration
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
- - - - - - - - - - - - - - - - - - - -
OSTRM
WAIT
P
LL
LD
T
OS
RSM
OSTSM
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The fields of the EC_CTRL register identified above are individually described below:
Field
Description of fields within Sub-Register 0x24:00 EC_CTRL
OSTSM
reg:24:00
bit:0
External transmit synchronisation mode enable. See section
OSRSM
reg:24:00
bit:1
External receive synchronisation mode enable. See section
PLLLDT
reg:24:00
bit:2
Clock PLL lock detect tune. This bit should be set to 1 to ensure reliable operation of the clock
PLL lock detect flags.
WAIT
reg:24:00
bits:10:3
Wait counter used for external transmit synchronisation and external timebase reset. See
sections
6.1.2 – One Shot Transmit Synchronisation (OSTS) Mode