4.4 Pump installation diagram
Fig. 12
Pump installation diagram.
1_Delivery pipe
2_Valve
3_Check valve
4_Pressure gauge
5_Motor
6_Pump
7_Breather hose
9_Leak collection
10_Compound gauge
11_Pump connection reducer
12_Base (refer to allowable forces and
moments tables)
13_Suction pipe (length equal to at least 10
times the suction Ø)
14_Minimum level equal to at least 3÷5 times
the diameter of suction
15_Compensation coupling
16_Cleaning piping (delivery side)
17_Cleaning piping (suction side)
The check valve protects the pump from possible water hammering.
The shut-off/regulation valve excludes the pump from the line and also adjusts the flow.
If there is a foot valve do not install a delivery check valve because the closing
of the foot valve before the check valve would cause water hammer which
harms pump performance.