SUPER RUNNER SERIES GAS FRYERS 

CHAPTER 1:  INSTALLATION INSTRUCTIONS

 

 

 

1-7

 

Series

 

Runner Series

 

Burner Orifice, 1.51mm  (#53)- 

NON-CE ONLY

SR52 

& SR62 Series Only

 

Burner Orifice, 2.53mm  (#39)- 

NON-CE ONLY

SR52 

& SR62 Series Only

 

Burner Orifice, 1.70mm  (#51)- 

NON-CE ONLY

SR42 

Series Only

 

Burner Orifice, 2.80mm  (#35)- 

NON-CE ONLY

S42 

Series Only

 

* Burner orifices listed above are for fryers operating at altitudes of 2000 feet (610 meters) or less.  For altitudes 
greater than 2000 feet (610 meters), contact the factory for the correct orifice size.

 

 

Summary of Contents for SR42 GM

Page 1: ...ED STATES For Service Call 318 865 1711 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 Price 10 00 8195999 08 2017 NON CE Super Runner Series Gas Fryers Installation Operation Manual Ser...

Page 2: ...ending upon the gas line connection Single fryers equipped with legs must be stabilized by installing anchor straps If a flexible gas line is used an additional restraining cable must be connected at...

Page 3: ...Register Your Warranty Online at http fm hal frymaster com qsys lib cgi lib swr290 pgm...

Page 4: ...ar of combustible material at all times NOTICE This appliance is only for professional use and shall be used by qualified personnel only CLEARANCE AND VENTILATION This fryer must be installed with a 6...

Page 5: ...e incoming gas pressure is in excess of PSI 3 45 kPa 35 mbar a step down regulator will be required CE UNITS ONLY Dean Super Runner gas fryers have obtained CE markings for countries and gas categorie...

Page 6: ...2 40 2 40 1 51 12 0 17 5 22 0 4 8 7 0 8 8 3 BLUE 3 BLUE 3 RED Blue Blue Red 26N 26N 16LP SR prefix Super Runner Series GM suffix gas millivolt system with no electrical supply connections required NO...

Page 7: ...ryers without depending upon the gas line connections If a flexible gas hose is used a restraining cable must be connected at all times when the fryer is in use NOTE The installation must be inspected...

Page 8: ...omponents Conversions can only be executed by qualified factory authorized personnel NON CE UNITS ONLY See gas valve illustration below and gas valve burner and orifice location on page 1 6 when perfo...

Page 9: ...tural Gas Conv Parts 1 8100811 Pilot Orifice 26N 3 8103464 Burner Orifice 2 40mm 42 1 8022530 Label Conversion Date SR52 CE Natural Gas to Propane Conv Parts 1 8102400 Pilot Orifice 16LP 3 8102059 Bur...

Page 10: ...r Orifice 2 53mm 39 NON CE ONLY SR52 SR62 Series Only Burner Orifice 1 70mm 51 NON CE ONLY SR42 Series Only Burner Orifice 2 80mm 35 NON CE ONLY S42 Series Only Burner orifices listed above are for fr...

Page 11: ...epress red button to turn the valve off 2 1 2 Pilot Lighting Procedures NOTE This fryer was tested adjusted and calibrated to sea level conditions before leaving the factory Adjustments may be necessa...

Page 12: ...heating tubes are covered in liquid prior to engaging burners NOTE If solid shortening is used pack the shortening into the frypot ensuring the shortening is packed beneath between and above the tubes...

Page 13: ...the solution to simmer for 10 15 minutes then drain and rinse the frypot with clean water twice Add cup of white vinegar to the last rinse to neutralize any alkalinity remaining from the detergent Wi...

Page 14: ...UNIT THERMOPILE HONEYWELL 807 3565 COAXIAL LEAD TO THERMOCOUPLE 812 1284 HIGH LIMIT OPERATING THERMOSTAT HONEYWELL CE PP TH PP TH NON CE UNITS ONLY 30 0 N O COM N C 200 2 5 0 OFF 1C 4C 3C HONEYWELL 1...

Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES Price 10 00 819 5999 08 2017...

Reviews: