background image

1-14 

1.8.4 Filtration 

Problems 

(cont.) 

 
3.

 

Prior to reassembly, the inside housing must be clean and free of any sediment or debris.  Failure 
to completely clean the inside housing and ring gear will cause gear binding after reassembly. 

 
Incorrectly sized or installed paper will allow food particles and sediment to pass through and clog 
the suction tube on the bottom of the filter carriage.  Particles large enough to block the suction tube 
may indicate that the crumb tray is not being used. 
 
Pan blockage can also occur if shortening is left in the pan and allowed to solidify. Heater strips (if 
equipped) on the oil return plumbing are designed to prevent solidification of shortening left in the 
plumbing.  Heater strips will not melt or prevent solidification of shortening in the pan. 

 

Blockage removal can be accomplished by forcing the item out with an auger or drain snake.  
Compressed air or other pressurized gases should not be used to force out the blockage. 
 
The electronics of the SUFF/UFF filtration systems are simple and straightforward.  Microswitches, 
attached to handles for each vat and wired in parallel, provide the 24 VAC required to activate the 
pump relay coil when the handles are moved to the ON position.  The activated pump relay coil pulls 
in the pump motor switch, supplying power to the pump motor. 
 
Filter systems equipped with oil-return heaters are wired into the 120 VAC source, which remain 
energized as long as the unit is plugged in. 

 

1.8.5 Leaking 

Leakage of the frypot usually will be due to improperly sealed high-limits, thermostats, or drain 
fittings.  When installed or replaced, each of these components must be sealed with Loctite PST567 
sealant or equivalent to prevent leakage.  In very rare cases, a leak may develop along one of the 
welded edges of the frypot.  When this occurs, the frypot must be replaced. 
 
If the sides and/or ends of the frypot are coated with oil, the most likely cause is spillage over the top 
of the frypot rather than leakage. 

 
 

Frypot locations (indicated by 
arrows) where potential leaks could 
occur. 

Summary of Contents for SM20GM

Page 1: ...t Service Association recommends using CFESA Certified Technicians MAY 2008 www frymaster com 24 Hour Service Hotline 1 800 551 8633 Email service frymaster com 8195948 Dean Millivolt Gas Fryers Service Parts Manual Super Runner and Super Marathon Series ...

Page 2: ...AND OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION THIS WARRANTY WILL BE VOID FURTHER FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY IN WHOLE OR IN PART DUE TO THE INSTALLATION OF ANY MODIFIED PART AND OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER DANGER Improper installa...

Page 3: ... spontaneously combust if left soaking in certain shortening material Additional information can be obtained in the filtration manual included with the system WARNING No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood Questions Call the Dean Service Hotline at 1 800 551 8633 WARNING Do not bang fry baskets or other utensils on the fr...

Page 4: ...hermostat 1 6 1 7 2 Replacing the High Limit Thermostat 1 8 1 7 3 Replacing the Gas Valve 1 8 1 7 4 Replacing the Frypot 1 8 1 8 Troubleshooting and Problem Isolation 1 9 1 8 1 Pilot Failures 1 9 1 8 2 Improper Burner Functioning 1 12 1 8 3 Improper Temperature Control 1 12 1 8 4 Filtration Problems 1 13 1 8 5 Leaking 1 14 1 9 Wiring Diagrams 1 15 1 9 1 Current Production Units with Honeywell Gas ...

Page 5: ...8 2 4 2 SR Series SM35G SM40G and SM50G Systems 2 10 2 4 3 SM60G and SM80G Systems 2 13 2 5 Oil Drain Manifold Drain Flush and Drain Valve Components 2 16 2 6 Oil Return Manifold Components 2 20 2 7 Oil Return and Oil Flush Components 2 23 2 8 Under Fryer Filter UFF Components 2 27 2 8 1 SM50 and SM60 Series Fryers Except IHOP 2 27 2 8 2 SM50 Series Fryers IHOP UFF 50 with Filter Leaf 2 28 2 8 3 S...

Page 6: ... 54 810 2050 810 2324 2 2 10 27 5 4 11 SM 35 40 GM SR 42GM 105 NAT LP 2 80 35 1 70 51 810 2040 810 3097 810 2064 810 3099 3 3 10 27 5 4 11 SR 52 GM SM 50 GM 120 NAT LP 2 53 39 1 51 53 810 2048 810 2059 4 4 10 27 5 4 11 SR 62 GM SM 60 GM SR 62 GM Australia 150 150 NAT LP NAT LP 2 53 39 1 51 53 2 53 39 1 61 52 810 2048 810 2059 810 2048 810 2063 5 5 5 5 10 27 5 9 24 4 11 3 6 9 6 SM 80 GM 165 NAT LP ...

Page 7: ...energizes the gas valve pilot coil which in turn opens the pilot valve If the pilot flame is extinguished voltage is lost to the gas valve pilot coil and the pilot valve closes Thermostats Dean millivolt fryers are equipped with adjustable operating thermostats The temperature at which the thermostat opens and closes is adjusted by turning a knob Dean millivolt fryers are also equipped with a high...

Page 8: ...cur This fryer may tip and cause personal injury if not secured in a stationary position 4 Relocate the fryer for service accessibility If fryer is equipped with legs lift the fryer to relocate it Damage to the leg or leg support channel can result if the fryer is not lifted when moving 5 After servicing is complete reconnect the unit to the gas supply and reattach the restraining devices 6 Refill...

Page 9: ...5 360 F 168 182 C If not calibrate as follows a Remove the thermostat knob by pulling straight out on the knob with a firm steady pull The temperature adjusting screw is located in the middle of the thermostat shaft b Insert a small bladed flat tipped screwdriver into the adjusting screw Turn the adjusting screw in turn increments to adjust the temperature Turning the screw clockwise decreases the...

Page 10: ...on and light pilot CE After the pilot is lit turn non CE gas valve to ON position set thermostat knob to 350 F 177 C When the burner lights and continues to burn note gas pressure reading for correct pressure in accordance with the table on page 1 1 5 To adjust burner gas pressure remove the cap from the gas valve regulator and adjust to correct pressure 6 Place the fryer power switch and the gas ...

Page 11: ...trailing pilot adjustment valve located on the burner manifold until a 1 inch 38 mm flame is obtained 1 7 Replacing Fryer Components 1 7 1 Replacing the Operating Thermostat 1 Drain the fryer and turn the gas off 2 Remove the thermostat knob by pulling straight out on the knob with a firm steady pull 3 Disconnect the wires from the thermostat 4 Remove the two mounting screws to release the thermos...

Page 12: ...s time 8 Position the thermostat bulb in tube mounted clamp and replace mounting hardware Ensure probe bulb is properly positioned in the clamp from burner tube and screws are properly tightened 9 Tighten the capillary tube compression nut once the capillary tube is properly positioned NOTE Once the compression nut is tightened the capillary tube cannot be repositioned If a mistake in installation...

Page 13: ...g so will clog and damage the gas valve 6 Reinstall new gas valve following steps 1 4 in reverse 1 7 4 Replacing the Frypot 1 Drain the frypot and disconnect the fryer from the gas supply 2 Remove all accessories e g frypot covers drop in probes basket hangers etc 3 Remove the screws from the cabinet back and remove it from the fryer 4 Remove the screws attaching the flue cap to the frypot and lif...

Page 14: ...llivolt systems always check these areas before performing diagnostic checks on either the Robertshaw or Honeywell systems A Inspect all wires and component leads for damage heat oil moisture etc On capillary tube type thermostats check for resistance on the thermostat lead wires Wire nuts and other connectors cannot be present in a millivolt circuit as they can cause resistance If resistance is f...

Page 15: ...etting Meter Leads On Terminals Acceptable Results 1 MV 2 3 100MV 2 MV 1 3 80MV 3 MV 1 2 30 120MV HONEYWELL SYSTEM CHECK 1 Complete System Check With thermostat contacts closed and gas cock dial in the ON position main burner should ignite If not measure across terminals 2 and 3 as indicated in the diagram If the reading is more than 180MV replace the gas valve 2 System Resistance Check With therm...

Page 16: ...lied to the pilot or to the burner manifold Check and Corrective Action Detach the high limit leads from the gas valve and check for continuity See page 1 10 If the high limit fails the continuity check it must be replaced 2 Loose corroded wiring connections on high limit or thermopile This has the same effect as a grounded or open high limit If the gas valve coils do not receive the appropriate v...

Page 17: ...ating correctly but the fryer has a slow recovery rate the length of time required for the fryer to increase the oil temperature from 275ºF to 325ºF 135ºC to 163ºC The primary causes of this are low burner manifold pressure and or misaligned burners If both of these causes are ruled out the probable cause is a gas valve regulator that is out of adjustment Refer to the Check Burner Manifold Pressur...

Page 18: ...ore often the pump overheated for one of the following reasons If solid shortening is used Shortening solidified in the pan or filter lines The operator attempted to filter unheated oil Cold oil is thicker and causes the pump motor to work harder and overheat If the motor runs but the pump does not there is a blockage in the pump Incorrectly sized or installed paper allows food particles and sedim...

Page 19: ... not be used to force out the blockage The electronics of the SUFF UFF filtration systems are simple and straightforward Microswitches attached to handles for each vat and wired in parallel provide the 24 VAC required to activate the pump relay coil when the handles are moved to the ON position The activated pump relay coil pulls in the pump motor switch supplying power to the pump motor Filter sy...

Page 20: ...OT 17C 17C 12C PILOT GENERATOR HIGH LIMIT THERMOSTAT SAFTY DRAIN SWITCH OPTIONAL IN LINE SPLICE ON OFF SWITCH OPTIONAL FENWALL OPERATING THERMOSTAT IN LINE SPLICE 8050438D OPERATING THERMOSTAT 1C 2C PP PP TH TH Combination Gas Valve High Limit Operating Thermostat White Red Black Red Red Black Thermopile TH TH PP PP Old Style Honeywell Millivolt Gas Valve Wiring Non CE ...

Page 21: ...1 16 1 9 2 Current Production Units with Honeywell Gas Valve CE FENWALL OPERATING THERMOSTAT HIGH LIMIT THERMOSTAT PILOT THERMOCOUPLE PILOT GENERATOR 8050531A ROBERTSHAW OPERATING THERMOSTAT TH TH PP PP ...

Page 22: ...1 17 1 9 3 Current Production Units with Robertshaw Gas Valve After May 2002 Thermopile Operating Thermostat High Limit Thermostat 1C 2C TH TH TP TP ...

Page 23: ...M OIL RETURN LH FRYER 8 LONG LEADS PN 807 1420 WHT 2 1 2 1 8 LONG LEADS 8 LONG LEADS HOSE CONNECTION OIL POLISHING WHEN USED NC WHT COM NC NO RED 1 2 1 2 WHT NO 1 1 WHT 2 1 COM NC RED NO BLK BLU T1 1 2 T2 3 4 P N 810 1164 BLOCK 24V NO COM 36 LONG LEADS 230V FILTER CIRCUIT 230V FILTER CIRCUIT P N 807 3611 NC R1 TRANSFORMER RELAY ASSY SCF OIL RETURN POWER P N 807 2196 SWITCH OPTIONAL P N 807 3577 FR...

Page 24: ...sket Hanger SM 50 Single Use 210 3131 for double 210 5109 Joiner Strip SM20 SM50 1 Channel Base Front Rear Non Filtration Single Fryers 12 0373 Channel Base Front Rear SR38G obsolete 200 1118 Channel Base Front Rear SR42G SR52G SM220G SM35G SM40G SM50G 200 5655 Channel Base Front Rear SR62G 200 3269 Channel Base Front Rear SM20G 200 2493 Channel Base Front Rear SM60G 200 2686 Channel Base Front Re...

Page 25: ...ide Panel Left 12 0380 1 Side Panel Left Painted Aluminum SR38G obsolete 201 1137SP Side Panel Left Painted Aluminum SR42G SR52G Use 202 5693SP for SR62G 211 3329 Side Panel Left SM20G 201 2858 Side Panel Left Painted CRS SM35G SM50G 201 1299 Side Panel Left Painted CRS SM50GDD 211 2076 Side Panel Left S S SR42G SM35G SM50G Use 211 5693 for SR62G 211 2532 Side Panel Left S S SM60G SM80G 15 Side Pa...

Page 26: ...Panel Inner Door SM220G SM35G SM40G SM50G 200 1185 Panel Inner Door SM60G 200 2688 Panel Inner Door SM80G 23 12 0308 2 Panel Door SR38G obsolete 210 4770 Panel Door SR42G SR52G Assembly 106 3150SP 210 5642 Panel Door SR62G Assembly 106 3444SP 106 4728 Door Assembly Right with Liner SM50 210 3805 Panel Outer Door SM20G Assembly 106 2482SP 210 2869 Panel Outer Door SM220G SM35G SM40G SM50G Assembly ...

Page 27: ... SM50G 5 201 2799 Panel Inner SUFF Base Left SM50G 6 202 3268 Panel Inner Right SM20G To SM50G 7 201 3268 Panel Inner Left SM20G To SM50G 8 200 1148 Base Channel Front Rear SM220G SM50G See Section 2 1 For Additional Single Fryer Base Channel Components 200 3154 Channel Double Front Rear SM80G Systems 4 Battery 9 823 3248 Support Leg All SM 60 80 Series Multi Battery Fryers With UFF 10 823 3539 Su...

Page 28: ...pcap SM360G 210 2825 Topcap SM460G 824 1009 Topcap SM280G 824 1010 Topcap SM380G 824 1011 Topcap SM480G 210 5109 Joiner Strip SM22G 210 3182 Joiner Strip SM50 60 SR62G 210 1679 Joiner Strip SM220 210 2681 Joiner Strip SR42 KIT00092SP Air Shutter Kit ACCESSORIES 803 0271 Basket Fry SM20 SM40 SM50 SR42 and SR52 803 0304 Basket Fry SM60 and SM80 803 0277 Screen Fine Mesh SR42 Use 803 0149 for SR62 SM...

Page 29: ...HAPTER 2 PARTS LIST 2 6 2 3 Component Box Components and Related Components CE and Domestic Components are applicable to all Millivolt fryers covered in this manual unless otherwise noted 1 2 9 10 11 12 13 14 15 16 17 3 4 5 6 8 7 ...

Page 30: ...106 1768SP ECO Connector Honeywell Valves Only CE ONLY 106 1879 ECO Connector Robertshaw Valves Only CE ONLY 10 200 5479 Bracket Pilot Thermocouple 11 810 2401 Bracket Thermopile 12 810 1001 Piezo Ignitor Trigger Wire Lead 807 3650 Assembly 44970SP 200 1868 Piezo Bracket 807 3540 Electrode Piezo CE Use 812 1532 for modified Electrode 13 807 1999 Transformer Dual Voltage CE Filtration System CE ONL...

Page 31: ...onents 2 4 1 SM220 and SM20 20 Systems 1 2 3 4 5 7 8 9 6 10 11 12 13 14 15 17 18 16 19 22 20 21 ITEM PART COMPONENT 1 813 0737 Nipple NPT x 21 BM 810 2043 Clamp Pipe BM Pipe 809 0805 Bolt Pipe Clamp 20 x Hex 200 1450 Bracket Gas Supply Clamp Support UFF Equipped Systems Not Illustrated ...

Page 32: ...al Robertshaw MV in x out 807 1603 Valve Gas Natural Honeywell in x out 810 2036 Valve Gas Natural Honeywell in x out 807 2122 Valve Gas Natural CE Honeywell 810 2399 Valve Gas Propane Robertshaw MV 807 1604 Valve Gas Propane Honeywell 807 2121 Valve Gas Propane CE Honeywell 810 0975 Knob Gas Valve Honeywell 810 0691 Vent Tube 4 Use 810 1166 for CE 3 86 18 826 1874 Frypot Assembly SM20G M S obsole...

Page 33: ...DEAN MILLIVOLT GAS FRYERS CHAPTER 2 PARTS LIST 2 10 2 4 2 SR Series SM35G SM40G and SM50G Systems 1 2 3 5 6 7 8 9 10 11 4 12 13 15 16 17 18 14 19 21 20 25 SM50G Shown 22 23 24 ...

Page 34: ...04 200 1330 Shield Burner Heat SR52G SM50 and 200 1331 6 200 1615 Bracket Manifold Mounting SR52G SM50G 200 1311 Bracket Manifold Mounting SR38G SR42G 7 809 0428 Bolt 20 x Hex Head 8 809 0823 Nut Nylock 20 9 813 0705 Plug Brass Square Head 10 Orifice Domestic International 810 2048 Orifice Natural 39 2 53 mm SR52G SM50G 810 2132 Orifice Natural 37 2 64 mm SR38G 810 2040 Orifice Natural 35 2 80 mm ...

Page 35: ...ure To Confirm Length 813 0585 Nipple NPT x 20 BM Measure To Confirm Length 813 0737 Nipple NPT x 21 BM Measure To Confirm Length 15 813 0174 Union NPT BM 16 813 0254 Nipple NPT x 3 BM SM50G 17 813 0066 Elbow NPT 90 BM 18 813 0112 Nipple NPT x 2 BM SM50G 19 809 0805 Bolt 20 x Hex Head 20 810 2043 Clamp Pipe 200 1450 Bracket Gas Supply Clamp Support UFF Equipped Systems 21 813 0031 Bushing NPT x NP...

Page 36: ...DEAN MILLIVOLT GAS FRYERS CHAPTER 2 PARTS LIST 2 13 2 4 3 SR62 SM60G and SM80G Systems 16 20 1 2 3 5 4 18 6 7 8 15 9 10 11 12 13 14 21 24 30 17 19 22 23 SM80G Shown 25 26 27 29 28 ...

Page 37: ...M80G SR62G adjustment valve 10 813 0642 Tee NPT 11 813 0705 Plug Brass Square Head 12 813 0643 Nipple NPT x Close BM 13 Orifice Domestic International 810 2062 Orifice Natural 38 2 58 mm SM80G 810 2048 Orifice Natural 39 2 53 mm SM60G SR62G 810 2063 Orifice LP 52 1 61 mm SM80G SR62G Australia 810 2059 Orifice LP 53 1 51 mm SM60G SR62G Orifice CE Only 810 2060 Orifice G20 G25 2 40 mm All Millivolt ...

Page 38: ...72 Gas Line Pilot Supply x 23 CE 810 2602 Gas Line Pilot Supply x 25 CE 27 810 2033 Thermopile Non CE 807 3565 Thermopile CE Only 28 810 2032 Burner Pilot Natural MFG Also Used For Main Pilot 106 0692 Burner Pilot Assembly Natural MFG 810 2155 Burner Pilot LP Also Used For Main Pilot 29 812 0703 Gas Line Trailing Pilot Supply x 17 Cut To Length 30 106 1442SP Flue Assembly SM80G 200 1316 Shield Flu...

Page 39: ...ifold Componets 2 5 1 1 Oil Drain Manifold Drain Flush and Drain Valve Components Typical components illustrated below Components will vary according to system 1 To Drain Valve To Drain Valve To Drain Valve 2 3 4 5 6 7 9 10 11 12 13 14 8 15 17 18 19 20 21 22 23 16 24 25 ...

Page 40: ...r Drain Valve 823 3440 Handle Push Pull Drain With Cap 809 0885 Washer x 1 x 083 809 0843 Pin Cotter 816 0547 Cap Vinyl Red 19 807 2104 Microswitch Optional On SUFF UFF Units 20 809 0842 Nut Nylock 4 40 Microswitch To Bracket 21 816 0220 Insulation Microswitch 22 200 1257 Retainer Nut 23 810 2127 Drain Valve 1 Full Port With Washers Nut 24 810 2052 Drain Valve 1 1 Standard Port 810 2442 Handle Val...

Page 41: ...Oil Drain Manifold Drain Flush and Drain Valve Components To Drain Valve To Drain Valve To Drain Valve To Drain Valve Stud located on underside of tube Place Over Stud Place Over Stud 23 22 13 18 15 17 19 16 21 13 20 19 14 20 21 14 1 3 6 7 9 5 4 8 2 22 11 12 10 ...

Page 42: ... 11 810 1668 Adapter Male O D x long 12 810 1056 Flexline O D x 52 5 long 106 3976 Drain Valve Assembly 1 Without Microswitch 106 3977 Drain Valve Assembly 1 With Microswitch 13 810 2783 Drain Valve 1 Full Port with O ring 14 823 4734 Handle Drain Valve Rotating 15 807 2104 Microswitch CE Micro roller Lever 16 106 1401 Microswitch Bracket Assembly 17 200 4402 Guard Drain Microswitch 18 816 0220 In...

Page 43: ...4 5 6 11 8 7 9 10 12 13 14 15 16 19 17 6 18 5 SM460G Oil Return Typical 2 ITEM PART COMPONENT 1 813 0003 Tee x x BM 2 813 0022 Nipple x Close NPT BM 3 813 0087 Nipple x 1 NPT BM 4 813 0156 Plug NPT Hex Head BM 5 813 0173 Union NPT BM 6 813 0247 Nipple x 3 NPT BM 7 813 0298 Nipple x 2 NPT BM 8 813 0345 Elbow 45 9 813 0368 Nipple x 16 NPT BM 10 813 0646 Nipple x 5 NPT BM 11 813 0654 Nipple x 4 NPT B...

Page 44: ...125 Oil Return Valve 810 0051 Coupling NPT x 1 7 16 to adapt return hose to valve 200 1143 Retainer Oil Return Valve Nut 809 0877 Nut Oil Return Valve 15 813 0006 Bushing Hex x NPT BM 16 813 0625 Nipple x Close NPT BM 17 813 0165 Elbow Street x NPT 90 BM 18 813 0634 Elbow x NPT 90 BM 19 813 0062 Elbow NPT 90 BM 106 2568SP Wash Down Hose and Nozzle Assembly Not Illustrated ...

Page 45: ...T BM 10 813 0362 Nipple NPT x 7 50 BM 11 813 0463 Plug Counter Sink 12 813 0661 Nipple x 2 25 NPT BM 13 813 0654 Nipple x 4 00 NPT BM 14 813 0597 Nipple x 11 50 NPT BM 810 2125 Ball Valve Drain 813 0006 Bushing to NPT BM Hex Reducing 813 0062 Elbow 90º BM 810 1067 Flexline 8 50 Oil Return 813 0087 Nipple x 1 50 NPT BM 813 0460 Nipple x 3 00 NPT BM 813 0625 Nipple NPT x CL Black CLS 813 0672 Nipple...

Page 46: ...IST 2 23 2 7 Oil Return and Oil Flush Components 2 7 1 Oil Return and Oil Flush Components Fryers with 1 Drains Typical components illustrated below Components will vary according to system 1 12 11 14 15 13 2 3 4 5 6 7 8 9 10 16 17 Rear View 18 ...

Page 47: ...813 0062 Elbow 90 BM 6 813 0515 Nipple x 12 NPT BM 7 813 0173 Union NPT BM 8 813 0251 Nipple x 4 NPT BM 9 813 0672 Nipple x 8 NPT BM 10 Oil Suction Start Fitting 813 0022 Nipple NPT x Close 813 0156 Plug NPT Hex Head 813 0003 Tee NPT BM 11 809 0885 Washer x 1 x 083 809 0843 Pin Cotter Plated 12 823 3344 Handle Actuator Oil Return Valve 13 823 3187 Handle Oil Return Left Fryer UFF System 14 823 319...

Page 48: ...DEAN MILLIVOLT GAS FRYERS CHAPTER 2 PARTS LIST 2 25 2 7 2 Oil Return and Oil Flush Components Fryers with 3 Drains ...

Page 49: ...ction Assembly 9 813 0062 Elbow 90º BM 10 813 0173 Union NPT 150 BM 11 813 0654 Nipple TBE NPT x 4 BM 12 813 0674 Nipple TBE NPT x 7 25 BM 13 200 1230 Bracket Front male Manifold 106 0774 Suction Manifold Assembly 14 810 0697 Disconnect Male Suction Tube 15 813 0608 Coupling NPT BM Full 16 823 3188 Suction Manifold 106 0858 Oil Suction Start Fitting 17 813 0022 Nipple NPT Close 18 813 0463 Plug Co...

Page 50: ... 3 809 0428 Bolt 20 x Steel 4 809 0820 Nut Oval Locking 20 5 823 4794 Insert Caster 6 810 2805 Caster 2 Swivel 7 823 3574 Support Grid Bottom Pan Screen UFF 50 823 3365 Support Grid Bottom Pan Screen UFF 60 8 803 0289 Filter Paper 22 x 34 UFF 50 60 100 Sheets 9 823 3573 Hold down Ring Weighted UFF 50 823 3361 Hold down Ring Weighted UFF 60 10 823 4320 Crumb Basket UFF 50 60 11 106 0752SP Lid Assem...

Page 51: ...HOP 2 810 2805 Caster 2 Swivel 3 809 0823 Nut Nylock 20 4 813 0336 Plug Pipe S S NPT 5 813 0679 Plug S S Square Head 6 810 2350 Leaf Filter UFF 50 IHOP 7 810 2351 Handle Filter Leaf Tee Fitting 8 823 3872 Crumb Basket UFF 50 IHOP 9 106 0752SP Lid Assembly Front UFF 50 10 106 0753SP Lid Assembly Rear UFF 60 11 810 0180 Handle Filter Lid Front Back 809 0191 Washer Lock Filter Lid Handle 809 0918 Scr...

Page 52: ... 3365 Support Grid Bottom Pan Screen Use 823 4938 for Chili s 3 803 0303 Filter Paper 26 x 34 100 Sheets 4 823 3439 Hold down Ring Weighted 5 823 3443 Crumb Basket 6 106 1587SP Filter Pan Cover Front 7 106 1588SP Filter Pan Cover Back 8 809 0428 Bolt 20 x Steel 9 823 4794 Insert Caster 10 809 0820 Nut Oval Locking 20 11 809 0805 Screw 20 x 12 810 2805 Caster 2 ...

Page 53: ...an SUFF 50 813 0684 Plug Hex Socket NPT 813 0679 Plug S S Square Head Female Disconnect 2 823 3790 Support Grid Bottom Pan Screen 3 803 0317 Paper Filter 8 x 25 4 823 3795 Hold down Ring Weighted 5 823 3736 Crumb Basket 6 823 3797 Filter Pan Cover Front 7 823 3798 Filter Pan Cover Back 8 809 0428 Bolt 20 x Steel 9 823 4794 Insert Caster 10 809 0820 Nut Oval Locking 20 11 809 0805 Screw 20 x 12 810...

Page 54: ...ct 2 823 3768 Support Grid Bottom Pan Screen SUFF 60 80 3 803 0289 Paper Filter 22 x 34 SUFF 60 80 4 823 3768 Hold down Ring Weighted SUFF 60 823 3849 Hold down Ring Weighted SUFF 80 5 823 3736 Crumb Basket SUFF 60 80 6 823 3766 Filter Pan Cover Front SUFF 60 823 3739 Filter Pan Cover Front SUFF 80 7 823 3767 Filter Pan Cover Back SUFF 60 823 3741 Filter Pan Cover Back SUFF 80 8 809 0428 Bolt 20 x...

Page 55: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 56: ...eport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 327 3343 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 819 5948 MAY 2007 ...

Reviews: