Dean Dartmoor 5 Operating Instructions Manual Download Page 2

 

Door Operation & controls 

 

The door handle can become very hot so use the glove provided. A tool is provided to control the spin 
wheel and air wash lever. 

 
 

Controlling the stove  
 

 

 

 

 

Diagram A:  

 

 

                                    

 

Primary air control      (A)

 on front of door. 

Secondary air control  (B) 

below the ash shelf  

 

The primary air control (A) is a spin wheel on the door. This control is used for lighting the fire or 
boosting the fire. This is also the main control when burning Solid Fuel. 

 
The secondary air wash control lever (B) situated under the ash catch lip controls the preheated air 
wash when burning wood once the fire in the stove is established. This lever should be used to control 
the fire. 
 
Control (B) works as follows: 
 
Fully in for maximum air flow into the stove and fully out for airflow to be shutdown. 
 
The stove is at its maximum efficiency when the lever is approximately half way.   
 

Lighting The Stove with Wood  
 

Lay a fire of sticks and paper.  Firelighters can also be used .  Check the secondary air lever is fully 
open and the primary air spinner partially open.  Light the fire and as the fire catches the paper you 
may then fully open the primary air vent. 
 
When the fire has fully established and the logs are burning well shut the primary air vent on the door 
and control the fire with the secondary air wash lever B (if you are unable to sustain the fire with 
secondary control it is very likely that your logs have a high moisture content). 
 
For longer periods of burning fill the firebox with wood and make sure the primary air vents are closed 
and the secondary air control is out fully. 
 

Summary of Contents for Dartmoor 5

Page 1: ...fitting other appliances into the room please check that adequate air vents are in place to cover the requirements of such appliances Extractor fans when operating in the same room or space as the ap...

Page 2: ...ows Fully in for maximum air flow into the stove and fully out for airflow to be shutdown The stove is at its maximum efficiency when the lever is approximately half way Lighting The Stove with Wood L...

Page 3: ...solid fuel in this stove you must only use fuels recommended for enclosed appliances Oil derivative fuels must not be used as this will shorten the life of the grate The Ash pan will need emptying onc...

Page 4: ...r basis No unauthorised modifications of the appliance should be carried out Use only replacement parts recommended by the manufacturer Refuelling Doors should always be closed in between refuelling t...

Page 5: ...e N B A suitably qualified person must fit the stove i e a HETAS engineer or with the supervision of building control As with all stoves fireguards must be installed when young children are present St...

Page 6: ...s to be fitted to the fireplace it should be 250mm above the top of the stove and 250mm at the sides these are minimum distances The appliance must be installed on a floor with an adequate low bearing...

Page 7: ...swinging arm located at the base of the stove Air Vent Very air tight properties designed with air permeability less than or equal to 5 0 m3 h m2 per hour an air vent will need to be fitted for all ki...

Page 8: ...e stove and will need screwing on and comes with a gauntlet and fire cement Fitting of M F kit for Dean Forge Dartmoor Inset Dean Forge Dartmoor Inset Multi Fuel Parts This M F kit consists of six par...

Page 9: ...ded each side of the stove Fit the back fuel guide C this fills the gap between the back of the stove and the main grate A make sure the bracket on the underside sits against the very back edge of the...

Page 10: ...Description of product Dartmoor wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in c...

Page 11: ...r 5 STDFDA5 STDFFOH STDFFOL Co 13 0 Wood 0 38 Ancit 0 40 5Kw 81 9 Wood 5Kw 70 7 Ancit 6931 1 Dartmoor W5 STDFDAW STDFHU co 13 0 Wood 0 38 Ancit 0 46 5Kw 80 6 Wood 5Kw 76 0 Ancit 60020 4 SE Dartmoor 6...

Page 12: ...12...

Page 13: ...ntees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims under this guarantee should be f...

Page 14: ...14...

Page 15: ...n Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number Date of Purchase Date of In...

Reviews: