background image

 

D

ean 

S

toves 

Dean Forge Fabrication Ltd. Dean Prior, Buckfastleigh, Devon TQ11 0LS 

 

T e l:   0 1 3 6 4  6 4 3 5 7 4        

 

w w w.d e a n–f o r g e.c o.u k     e m a i l:  s t o v e s @ d e a n-f o r g e.c o.u k

 

 

 

Operating Instructions for The Dean Forge Dartmoor Baker 8 Stove 

DBM8 issue 1. July 2015 

All stoves meet the essential type test requirement BS EN13240:2001 + 
A 2:2004 

 

 
 Safety Note 

 
Warning- The external parts of the appliance will get very hot to the touch and due care will be needed 
when operating. 
 
All stoves before being operated must be checked that the installation complies with all local, national 
and European standards.  
 
Before the stove is first used or when fitting other appliances into the room, please check that adequate 
air vents are in place to cover the requirements of such appliances. 
 
 

Extractor fans. 

 When operating an extractor fan in the same room or space as the appliance the 

extractor fan could cause the stove not to function properly and pull dangerous fumes into the room. 
This must be checked by a trained qualified engineer before using the stove. 
 

Wood & Suitable fuels 

 

Dry wood, 18% moisture content or below must be used or the stove and flue will tar up and the 
door won’t stay clean. 

Wood is best seasoned by splitting it into a log and drying it out for 2 years in a covered area so the air 
can pass through to dry it out.  Peat can also be used but must be dry. 

 
 

 

When used as a Multi Fuel use only smokeless fuels recommended for enclosed appliances. 

 

Please Note:

 Appliances should not be used as general incinerators or with non-recommended fuels. 

At no time

 should liquid accelerants I.e.: Paraffin, Petrol, BBQ lighting liquid Etc be used. 

 
     

Door Operation & controls 

 

The door handle can become very hot so use the glove provided. A tool is provided to control the spin 
wheel and air wash lever. 
 

 

 

Maximum Log Length 

Maximum Log Diameter  

400mm 

100mm 

Summary of Contents for Dartmoor Baker 8

Page 1: ...ractor fan in the same room or space as the appliance the extractor fan could cause the stove not to function properly and pull dangerous fumes into the room This must be checked by a trained qualifie...

Page 2: ...y two thirds the way down Dampers Left Open Operation with the air controls or appliance dampers open can cause excess smoke The appliance must not be operated with the air controls appliance dampers...

Page 3: ...an ash clean attachment which can be plugged into your vacuum cleaner Please note If there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occ...

Page 4: ...w unwanted cooking smells out of the oven and into the chimney Do not block this vent off The top plate can be used as a cooking surface with the hottest area being near the back Please note if you do...

Page 5: ...ult finding If the stove starts emitting fumes into the room 1 Check there is no blockage or restriction in the flue 2 Check the external air vent is not blocked 3 Check the baffle plate has not dislo...

Page 6: ...or all stoves of 5 kilowatts and over or meet current building regulations Stoves must be fitted to BS8303 BS6461 PT1 2 1984 building regulations All local regulations including those referring to nat...

Page 7: ...oved to facilitate cleaning through the stove Hearth Surround and Register Plate The stove must stand on non flammable material at least 12mm thick 1 2 The hearth must extend at least 225mm in front o...

Page 8: ...15 C Dean Forge Dartmoor Baker 8 Solid Fuel Ancit 320 C Flue Gas Mass Flow Stove Types Flue gas mass flow gs Dean Forge Dartmoor Baker 8 Wood Burning 7 2 Dean Forge Dartmoor Baker 8 Solid Fuel Ancit 7...

Page 9: ...taken into account Please Note Extractor fans when operating in the same room or space as the appliance may cause problems Air vent inlet grills must not be inadvertently blocked Air vents must not be...

Page 10: ...e box with the wedge on the MF grate A facing up and forward Refit the Fuel retainer B remembering the lugs face towards the front of the stove and the cut out faces down Leave out the ash retainer th...

Page 11: ...Description of product Dartmoor wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in c...

Page 12: ...r 5 STDFDA5 STDFFOH STDFFOL Co 13 0 Wood 0 38 Ancit 0 40 5Kw 81 9 Wood 5Kw 70 7 Ancit 6931 1 Dartmoor W5 STDFDAW STDFHU co 13 0 Wood 0 38 Ancit 0 46 5Kw 80 6 Wood 5Kw 76 0 Ancit 60020 4 SE Dartmoor 6...

Page 13: ...evant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims under this guarantee...

Page 14: ...14...

Page 15: ...n Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number Date of Purchase Date of In...

Reviews: