![Dea LOOK Operating Instructions Manual Download Page 4](http://html1.mh-extra.com/html/dea/look/look_operating-instructions-manual_2461009004.webp)
9
4.4 Adjustment of the limit-switches
After the installing, limit switches must be adjusted (only for models that foresee them) as follows (Pic. 9):
WARNING
When adjusting the limit switches, take away the little cover of the extrusion using a screwdriver and check the correct
internal microswitches are moving (Pic. 10).
WARNING
While closing the inspection cover, use silicone to seal the leak (Pic. 11).
5 ELECTRICAL CONNECTIONS
WARNING
To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm in the
open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits
power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING
To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
2
.
WARNING
During the connection phase, fasten the electric cables with appropriate clamps near the terminal boards and, when possible,
unsheathe the cables to avoid they are too long.
Connection for 24V and 230V
Connection for 24V and 230V with limit switches
24V
CLOSE
OPEN
M
FCC
FCA
N.C.
N.C.
FCA
COM
FCC
1(red)
2(blue)
4(brown)
5(blue)
7(brown)
6(blue)
CENTRALE DI COMANDO,
ELECTRONIC BOARD, ARMOIRE DE
COMMANDE, CUADRO DE
MANIOBRAS, CENTRAL DE
COMANDO, CENTRALI STERUJĄCEJ
230V
CENTRALE DI COMANDO,
ELECTRONIC BOARD, ARMOIRE DE
COMMANDE, CUADRO DE
MANIOBRAS, CENTRAL DE
COMANDO, CENTRALI STERUJĄCEJ
CLOSE
COM
OPEN
M
FCC
FCA
N.C.
N.C.
FCA
COM
FCC
1(white)
2(blue)
3(black)
4(brown)
5(blue)
7(brown)
6(blue)
Connection for 230V version with encoder
230V with encoder
M
1(white)
2(blue)
3(black)
ENCODER
}
white
green
brown
CLOSE
COM
OPEN
white
brown
green
WARNING
Maintain the ground conductor at a major length respect the active conductors so that, if the cable exit from its fixing housing,
the active conductors tighten up as first.
WARNING
Respect the Phase-Neutral polarity of the tension as explained by the instructions manual of the control panels of LOOK.
Summary of Contents for LOOK
Page 1: ... Operating instructions move as you like www deasystem com ...
Page 8: ...4 1 1 2 2 2 2 500 mm 250 mm 200 mm ...
Page 10: ...D A C A Closing cycle Closing cycle Opening cycle Opening cycle ...
Page 11: ...41 ...
Page 12: ...42 APRE CHIUDE APRE CHIUDE COMUNE 4x1 mm 3x1 5 mm 24V 230V ...
Page 14: ......