INSTALLATION SUGGESTIONS
The installation illustrated in the figure on the side
is suggested.
A non-return valve shall be installed in the outlet
water pipe (A). This protects the softener from hot
water flowing back and damaging the softener.
A-NON-RETURN VALVE
B-OUTLET WATER TAP
C-BY-PASS TAP
D-INLET WATER TAP
E-OVERFLOW PIPE
F-DRAIN PIPE
G-INLET WATER PIPE
H- OUTLET WATER PIPE
I-OVERFLOW COUPLING
L- ID LABEL
M- MIXING PIECE
LOCATION SUGGESTIONS
The distance between the softener and the drain
system shall be as short as possible.
If the drain pipe is located at a higher level than the
softener, maximum height shall be 1.8 meters,
provided that the pipe is no longer than 5 meters and
that water pipe pressure is at least 3 bars.
If the softener is close to a boiler, water pipes and the
softener shall not be impacted by excessive heating.
Whenever possible, it is advisable to keep at least a
3-metre distance between the softener's outlet water
pipe and the boiler's inlet water pipe.
Do not install the softener close to acid and/or
corrosive substances and/or fumes.