background image

Revised   23  June   2000 

Pag 3

.

 

Top 

Back 

Sides

 

Front 

Ü

  Minimum distances from 

inflammable surfaces 

0,3 m. 

0,1 m. 

0,1 m. 

2,0  m.

 

The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above 
table are the minimum distances recommended.  

Other requirements for safe use are:

 

 

A.  Do not cover the apertures of the luminaire housing. They are essential for correct ventilation. Do not use on 

the floor. It reduces the ventilation. 

B.  Use only original accessories and spares from De Sisti Lighting. 
C.  Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the 

luminaire weight. 

D.  A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between 

the suspension point and the eyelet at the front of the body . 

WARNING : 

DO NOT  MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE . 

WARNING : UV RISK .

 

The lamps usable  on the luminaire  emit an amount of UV RADIATION  very dangerous 

for human health  if not properly  shielded . 
For this reason  the luminaire  MUST NEVER  BE USED  IN THE SITUATIONS WHEN DIRECT  LIGHT  
EMISSION FROM THE LAMP CAN OCCURR  ( ex : Damaged or no  front  lens  , no mirror , damaged internal 
baffles , additional aperture on the housing )  
 

4.  INSTALLATION INSTRUCTIONS 

Before connecting the luminaire

 to the ballast  ensure that: 

A – The ballast is compatible with the luminaire  . 
B  - The ballast is suitable for the electrical mains ( Voltage & Frequency )  . 
C  – The ballast is properly earthed  ( use the  ground continuity test present on  De Sisti ballast ) and the 
ballast main switch  is in OFF position . 
D - The lamp fitted :  

Ü

  is among the usable lamps  ( see point 6  or check with  your De Sisti dealer )   

Ü

  ( for magnetic  ballast ) has the nominal power equal  to the  ballast. 

Ü

  (for  De Sisti Electronic Ballast , single or dual power ) has nominal power not higher than the Max 

of the ballast .   

E – The front safety shields against the lamp explosion are present and in good condition. 

They consist  of a  fresnel lens plus wire guard . The fresnel lens is made of borosilicate untoughened 
glass D= 150 mm , thickness 5 mm typ ( 3 mm min ) , compliant to DIN 15560 . The wire guard is a 
mesh 25 mm x 25 mm( or smaller ) ,  wire  D=0,8 mm typ , made by nickel coated or stainless steel . 

 

After connection to the ballast

 , follow the ballast instruction to operate  on the system . 

 
WARNING :

 SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE 

BECOME VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR 
EXAMPLE BY CRACKS OR DEEP SCRATCHES.  
THE LUMINAIRE  SHALL ONLY BE USED  COMPLETE  WITH ITS PROTECTIVE SHIELD . 

 

5.  LAMP INSTALLATION AND REPLACEMENT 

The following procedure should be adopted: 
A - Ensure the luminaire is electrically isolated from the power supply. 
B  -WAIT AT LEAST 5 MINUTES FROM SWITCHING OFF to avoid risk of injury from possible lamp explosion. 

Then open lens door . 

WARNING:

 AFTER THE  ABOVE MENTIONED TIME THE LAMP MAY STILL BE VERY HOT, USE 

PROPER THERMAL PROTECTION (EG. GLOVES). 

C - Check that the new lamp is of the correct type. 

SEE WARNING FOR INSTALLATION (  ITEM 4 – D ) . 

D - Replace the lamp taking good note of the following: 

 

do not touch the bulb with bare-hands; oil and grease can contaminate the bulb surface and then reduce 
the performance and the lamp life. 

 

the plastic cover which protects the lamp should not be removed until after fitting. 

 

should the bulb become dirty due to hand contact or for any other reason, it can be cleaned with a cloth 
moistened with alcohol. 

 

instructions by lamp manufacturers  must be  followed .  

E - Ensure that  the lens door is securely closed. 

 

Summary of Contents for REMBRANDT PICCOLO 575 w SE

Page 1: ...De Sisti Lighting Our commitment to Total Customer Satisfaction and our consolidated experience and leadership in design innovation and manufacturing of lighting products for the professional Entertainment Industry means you can depend upon the quality of this product The REMBRANDT PICCOLO 575 W SE is a compact highly efficient fresnel lens Spotlight using Single ended Hot Re strike metal halide d...

Page 2: ... Ü Grounding This luminaire is used only with De Sisti ballast THE BALLAST MUST BE GROUNDED Ü Electrical connections DO NOT CONNECT THIS LUMINAIRE DIRECTLY TO THE ELECTRICAL MAINS The supply cord ends with a dedicated connector By this connector the luminaire must be connected to PROPERLY RATED DE SISTI BALLAST magnetic or electronic The wiring diagram of lamp house and connector is shown herebelo...

Page 3: ...ler Ü for magnetic ballast has the nominal power equal to the ballast Ü for De Sisti Electronic Ballast single or dual power has nominal power not higher than the Max of the ballast E The front safety shields against the lamp explosion are present and in good condition They consist of a fresnel lens plus wire guard The fresnel lens is made of borosilicate untoughened glass D 150 mm thickness 5 mm ...

Page 4: ...ve lamps 7 PERIODIC INSPECTION A The condition of the internal wiring insulation shall be inspected and tested every 500 working hours and at least once a year This frequency may need to be increased if rough or unknown eg rental treatment is incurred Replace only with original De Sisti Lighting spare parts Non original cables may not withstand the thermal and mechanical conditions of use B The la...

Page 5: ...e Applicable European Directives Standards America the product conforms NEC UL stds Ü Low Voltage Directive 73 23 EEC as amended by 93 68 EEC Ü EMC Directive 89 336 EEC as amended by 92 31 EEC and 93 68 EEC Ü Europen Standards EN 60598 2 17 EN 60598 1 EN 55015 UL Standard 1573 ...

Reviews: