background image

Revised  25  November 1999

Pag 3

.

4. WORKING CONDITIONS

Â

 Working Position

Lighting fixture:

 Max. Tilting 

±

90° from horizontal

Lamp:

 S90

Â

 Ambient Temperature, 

t

a

 +45° C  Max

Top

Back

Sides

Front

Â

  Minimum distances from

inflammable surfaces

0,3 m.

0,1 m.

0,1 m.

1 m.

The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above
table are the minimum distances recommended. Other requirements for safe use are:

A. 

Do not cover the apertures of the luminaire housing. They are essential for correct ventilation. Do not use
on the floor. It reduces the ventilation.

B. 

Use only original accessories and spares from De Sisti Lighting.

C. 

Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept
the luminaire weight.

D. 

In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting.

E. 

A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between
the suspension point and the eyelet at the front of the body .

WARNING : 

DO NOT  MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE .

5. INSTALLATION INSTRUCTIONS

Before connecting the luminaire to the electrical mains ensure that:

A. 

Earth line is present on the power socket.

B. 

The mains voltage is within the rated range of the luminaire (see technical data on the rating label)

C. 

The lamp fitted:

  is among the usable lamps  ( see point 6  or check with  your De Sisti dealer )

  has the same nominal voltage as the mains supply

  has a nominal power not higher than maximum power of the luminaire.

D. 

The front safety shields against the lamp explosion are present and in good condition.
They consist  of  fresnel lens plus  wire guard  . The fresnel lens is made by borosilicate untoughened
glass  D = 150 mm , thickness = 5 mm typ ( 3 min ) , compliant to DIN 15560 . The wire guard is a mesh
25 mm x 25 mm ( or smaller ) , wire D = 0.8 mm typ , made by nickel coated  or stainless steel .

WARNING :

 SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE

BECOME VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR
EXAMPLE BY CRACKS OR DEEP SCRATCHES.
THE LUMINAIRE  SHALL ONLY BE USED  COMPLETE  WITH ITS PROTECTIVE SHIELD .

6.  LAMP INSTALLATION AND REPLACEMENT

The following procedure should be adopted:

A. 

Ensure the luminaire is electrically isolated from the power supply.

B. 

WAIT LEAST 5 MINUTES FROM SWITCHING OFF to avoid risk of injury from possible lamp explosion.
Then open lens door .

WARNING: 

AFTER THE ABOVE MENTIONED TIME THE LAMP MAY STILL BE VERY HOT, USE

PROPER THERMAL PROTECTION (EG. GLOVES).

C. 

Check that the new lamp is of the correct type ( see item 5 .C).

D. 

Replace the lamp taking good note of the following:

  do not touch the bulb with bare-hands; oil and grease can contaminate the bulb surface and then

reduce the performance and the lamp life.

  The plastic cover which protects the lamp should not be removed until after fitting.

  Should the bulb become dirty due to hand contact or for any other reason, it can be cleaned with a

cloth moistened with alcohol

E. 

Ensure that  the lens door is securely closed.

WARNING : 

THE LAMP MUST BE REPLACED IF IT HAS BECOME DAMAGED OR DEFORMED .

Summary of Contents for LEONARDO 310

Page 1: ...e manufacturing of lighting products for the professional Entertainment Industry mean you can depend upon the quality of this product The LEONARDO 1 kW is a compact highly efficient Fresnel lens spotlight using tungsten quartz halogen filament lamps having G22 socket L C L of 63 5 mm and max 1 kW power max 1 2 kW available at 230V NOTE Also available on special request a version using tungsten qua...

Page 2: ...Europe America Ground Green yellow Green or green yellow Neutral Blue White Live Brown Black In case the colors of the cores do not correspond to the colors of the connection points on your plug please proceed as follows the green or green and yellow core must be connected to the connection point marked with the letter E or with the symbol or colored in green or in green yellow the blue or white c...

Page 3: ...ins supply has a nominal power not higher than maximum power of the luminaire D The front safety shields against the lamp explosion are present and in good condition They consist of fresnel lens plus wire guard The fresnel lens is made by borosilicate untoughened glass D 150 mm thickness 5 mm typ 3 min compliant to DIN 15560 The wire guard is a mesh 25 mm x 25 mm or smaller wire D 0 8 mm typ made ...

Page 4: ... G22 1200 w BP CP 93 Not available GX9 5 650 w MP CP 23 CP23 GX9 5 650 w BP FVC CP 67 Not available GX9 5 1000 w MP CP 24 Not available GX9 5 1000 w BP FVA CP 70 Not available GX 9 5 only on special version 8 PERIODIC INSPECTION A The condition of the internal wiring insulation and of the input cable shall be inspected and tested every 500 working hours and at least once a year This frequency may ...

Reviews: