Preface 

 

Thank you for choosing the products of Dandong Top Electronics Instrument (Group) Co., Ltd. 
 
This  operation  manual  provides  you  with  important  information  on  installation,  connection  and 
commissioning  as  well  as  on  maintenance,  troubleshooting  and  storage.  Please  read  it  carefully 
before installation and commissioning and keep it as part of the product near the meter for easy 
reading. 
 
This manual can be downloaded by entering the version number at 

www.ddtop.com

 

 
If the instructions are not followed, the protection provided by the meter may be destroyed. 
 
Trademark, Copyright and Restriction Instructions 
Dandong Top Electronics Instrument (Group) Co.,Ltd.®, Dandong Top Pump Co., Ltd.®, DDTOP® 
are registered trademarks of the company. 
 
he  performance  specifications  of  the  meter  are  effective  as  of  the  date  of  publication  and  are 
subject to change without notice. Dandong Top Electronics Instrument (Group)Co.,Ltd. reserves the 
right to modify the products described in this manual at any time without prior notice. 
 
 
Quality Assurance 
Dandong  Top  Electronics  Instrument  (Group)  Co.,Ltd.  guarantees  that  all  glass  plate  level  gauge 
have no defects in materials and manufacturing processes within one year from the date of delivery. 
 
During  the  warranty  period,  if  the  product  returns  with  quality  problems  and  the  claim  is 
determined  by  the  manufacturer  to  be  within  the  scope  of  warranty,  Dandong  Top  Electronics 
Instrument (Group) Co.,Ltd. is responsible for repair or replacement of the buyer (or owner) free of 
charge. 
 
Dandong  Top  Electronics  Instrument  (Group)  Co.,Ltd.  is  not  responsible  for  the  costs  caused  by 
improper use of equipment, labor claims, direct or subsequent damage and installation and use of 
equipment. In addition to the special written warranty certificate for certain products of Dandong 
Top Electronics Instrument (Group) Co.,Ltd., Dandong Top Electronics Instrument (Group) Co.,Ltd. 
does not provide any express or implied warranty. 
 
Quality 
Dandong  Top  Electronics  Instrument  (Group)  Co.,Ltd.  has  passed  the  ISO9001  quality  system 
certification. The whole process of product production is strictly in accordance with the scope of the 
quality system, providing the strongest guarantee for product and service quality. 
 

Summary of Contents for UQK-400

Page 1: ...1 10 WWW DDTOP COM UQK 400 FLOAT LEVEL SWITCH Operation Manual UQK 400 DT JS 1019 2018 A ...

Page 2: ...ut prior notice Quality Assurance Dandong Top Electronics Instrument Group Co Ltd guarantees that all glass plate level gauge have no defects in materials and manufacturing processes within one year from the date of delivery During the warranty period if the product returns with quality problems and the claim is determined by the manufacturer to be within the scope of warranty Dandong Top Electron...

Page 3: ...ing 5 2 5 Warehousing 5 3 Technical Characteristics 5 3 1 Main Performance 5 3 2 Main Parameters 5 4 Dimensional Schematic Figure 2 6 5 Unpacking and Inspection 6 5 1 Unpacking Inspection Notice 6 5 2 Check Content 6 6 Installation 7 6 1 Installation Tool 7 6 2 Installation Technical Requirements 7 c6 3 Installation Process 7 7 Debugging 7 7 1 Preparation for Commissioning 7 7 2 Electrical Wiring ...

Page 4: ... in Intrinsically safe or non flammable site operating procedures 1 2 Process Leaks Can Cause Serious Injury or Death Care should be taken to lift the transmitter If the process seal is damaged the medium may leak at the joint 1 3 Failure to Follow Safe Installation Guidelines May Result In Death or Serious Injury The operations described in this manual are performed by professionally trained and ...

Page 5: ...e action of buoyancy so that the magnetic rod at the end of the connecting rod moves downward in the opposite direction the magnetic rod is separated from the magnetic field of the magnetic switch assembly and the magnetic control switch returns to the original state or under the action of self weight the biased magnetic steel returns to a new equilibrium position so that the switch contacts are t...

Page 6: ...ctual size will prevail Figure 2 5 Unpacking and Inspection 5 1 Unpacking Inspection Notice 5 1 1 Check whether the product nameplate Figure 4 is consistent with the supply list information Figure4 Sample Nameplate 5 1 2 对照装箱清单 检查各零件数量 材质是否正确 5 1 2 Check the quantity of each part against the packing list and the material is correct 5 2 Check Content ...

Page 7: ...ng performance 6 2 4 The liquid surface fluctuation frequency of the measured medium shall not be too large and the fluctuation range shall not exceed the allowable action limit 6 3 Installation Process 6 3 1 Place the gasket on the sealing surface of the container flange 6 3 2 Carefully pick up the controller and load the float into the container 6 3 3 Align the controller flange with the contain...

Page 8: ...end and the low report is connected to the two pairs Opening point public end Figure 4 Electrical Wiring The normally open and normally closed points in the wiring diagram refer to the original state of the micro switch or reed switch 3 All terminals should be in good contact the output nut should be properly pressed to prevent the lead from loosening 4 Ensure that excess wires do not interfere wi...

Page 9: ...each into the tank 5 Ferromagnetic particles or obstacles in the medium cause the float ball to block 6 Magnetic switch assembly failure 1 Confirm the density or replace the float 2 Replace the float 3 Confirm the installation position according to the instructions to ensure that the head is flushed 4 Confirm that the order neck is larger than the length of the guide tube If the neck is small cont...

Page 10: ...10 10 WWW DDTOP COM ...

Reviews: