F U N C T I O N C A L L S
void WINAPI Start_TwoSpeed(int Card, int Channel, int Start)
DESCRIPTION
This routine is used to Start (1) or Stop (0) the Two Speed rotation.
INPUT DATA
Card = an integer between 0 and 7 for the card of interest. The card number is set in the
MOTION FEEDBACK BOARD MANAGER.
Channel = an integer between 0 and 2 for the channel pairs of interest.
0 = Channel 0 (Coarse) and Channel 1 (Fine)
1 = Channel 2 (Coarse) and Channel 3 (Fine)
2 = Channel 4 (Coarse) and Channel 5 (Fine)
Start = an integer that is either a (1) to Start, or a (0) to Stop dynamic rotation.
RETURNED DATA
This routine does not return any data.
EXAMPLE CODE
Code Result/Returned
Data
Start_TwoSpeed(1,0,1);
Starts Two Speed rotation for
card #1, channel 0 (Coarse) and
channel 1 (Fine).
Data Device Corporation