DCS Vent Hood ES30 Installation Manual Download Page 9

8

BEFORE INSTALLING HOOD

1. For the most efficient air flow exhaust, use a straight run or as few elbows as possible. Maximum

duct length is 40 feet, including elbows.

CAUTION:  

Vent unit to outside of building only.

2.  Two people are necessary for installation.

3. The hood is fitted with Screws and Drywall Anchors suitable for most surfaces. Consult a qualified

installer.

4. Do not use flex ducting.

5. COLD WEATHER installations should have an additional backdraft damper installed to minimize the

back flow of cold air and nonmetallic thermal break to minimize conduction of outside temper-
atures as part of the ductwork.  The damper should be on the cold air side (outside wall) of the
thermal break.  

The break should be as close as possible to where the ducting enters the heated portion of the
house.

6. Local building codes may require the installation of a make-up air system.  Consult your HVAC

professional for specific requirements in your area.

7. Hood installation height above cooktop is the users preference.  Lower installation heights will

improve the efficiency of capturing cooking odors, grease, and smoke.  This hood has been
approved for installation heights 30” above the cooktop.  Taller people may find a 30” installation
height is inconvenient.  DCS recommends an installation height between 30” and 36”.

8. ES30 and ES36 hood models are not recommended to be used over indoor range grills.

9. For installation over DCS Range and Cooktop models RGS-364GL or CS-364GL, the VS1236 model

vent is recommended.

10. Make sure your range or cooktop is level.

TYPICAL INSTALLATION

The hood can be installed using a wall mounting system or suspended under existing cabinetry in the
kitchen.  Ducting can be configured for both vertical and horizontal discharge. 

If an infrared kit was purchased for installation with the hood, assemble the kit to the hood prior to
installation.  

For wall mount instllations, duct cover kits can be purchased as spacers between hood and ceiling.
Duct covers are assembled to unit after the hood is installed.

Summary of Contents for Vent Hood ES30

Page 1: ...THE PROFESSIONAL AND EURO VENT HOOD Installation Guide MODELS VS30 VS36 VS48 RDS 364GD VS1236 ES30 ES36 486GD...

Page 2: ...on the inner back panel behind grease filters below motor assembly MODEL NUMBER CODE SERIAL NUMBER WARNING If the information in this manual is not followed exactly a fire or explosion may result cau...

Page 3: ...persons in the event of a rangetop grease fire observe the following Turn burner off first Smother flames with a close fitting lid cookie sheet or metal tray Be careful to prevent burns If the flames...

Page 4: ...ent air is needed to maintain proper combustion and safe exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturers guide...

Page 5: ...etal tray then turn off the gas burner or the electric element BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN y...

Page 6: ...pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whe...

Page 7: ...12 Duct Cover Accessory Height ES30 14 15 16 ES36 17 15 16 12 6 25 2 18 6 or 12 Duct Cover Accessory Height VS30 29 7 8 VS36 VS1236 35 7 8 VS48 47 7 8 VS30 29 7 8 VS36 VS1236 35 7 8 VS48 47 7 8 VS30 1...

Page 8: ...ral Blower PARTS NOT INCLUDED WITH YOUR HOOD Ducting See Page 9 for duct requirements 8 or 10 to be used Duct Tape 1 2 Conduit Wire Nuts Optional duct cover 6 or 12 height VDC1230 12 Duct cover kit fo...

Page 9: ...cific requirements in your area 7 Hood installation height above cooktop is the users preference Lower installation heights will improve the efficiency of capturing cooking odors grease and smoke This...

Page 10: ...36 are supplied with a starting collar and backdraft damper on top of the hood for connection to 8 round duct Models VS1236 and VS48 are supplied with a 10 round transition with damper and is assemble...

Page 11: ...uct covers can be joined together in any combination 1 Hood Installation Height After the hood installation height has been determined draw a horizontal line at a distance above the cooktop equal to t...

Page 12: ...tud 7 Use 2 to 4 1 4 x 3 flat head wood screws to attach the bracket to the wall as shown in Figure 4 For support of longer hoods use three or four studs as available Countersink the heads to prevent...

Page 13: ...screws and seal with duct tape Screws must not hamper the damper 15 Drill a 3 8 hole through the center of the holes K into the wall Insert two wall plugs into drilled holes Tighten hood to wall anch...

Page 14: ...H G I 1 1 2 Dia Holes Vertical conduit option A B C D E F G H I Min 12 6 10 6 3 4 1 7 8 5 3 4 5 7 8 1 7 8 5 1 8 ES30 30 ES36 36 C L Cabinet Vertical Discharge Cutout Width Bottom of Cabinet or Soffit...

Page 15: ...pace of about 1 2 from cabinet bottom surface and screw heads 4 Hang the hood on screws through side slots provided on hood top Tighten the four screws Drill a 3 8 hole through the center of the holes...

Page 16: ...e j box cover as shown in Figure 11 3 Remove 1 of 2 knockouts and install 1 2 conduit connector in j box 4 Run black white and green wires 18 AWG in 1 2 conduit from power supply to j box 5 Connect th...

Page 17: ...nd grease filters below motor assembly Serial Number located on the inner back panel behind grease filters below motor assembly Code located on the inner back panel behind grease filters below motor a...

Page 18: ...r of attempts at our option we may replace the part or the Product or we may provide you a full refund of the purchase price of the Product not including installation or other charges This warranty ex...

Page 19: ...limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you HOW TO GET SERVICE Please read your Use and Care Guide If you then have any questions about...

Page 20: ...dcsappliances com As product improvement is an ongoing process we reserve the right to change specifications or design without notice Nous am liorons constamment ses produits et se r serve le droit d...

Reviews: