background image

16

Warranty Information

Length of Warranty

One (1) Year Full parts and Labor 

Covers the entire product

Five (5) Years Limited 

Switches and motor

All repair labor and parts found to be defective due to materials or workmanship for
one full year from date of purchase. Service must be provided by an 

Authorized

Factory Service Agent

during normal working hours.

Installation or start-up

General maintenance

Shipping damage

Service by an unauthorized agency

Damage or repairs due to service by an unauthorized agency or the use of
unauthorized parts.

Service during other than normal working hours

Improper installation, such as improper hook-up, etc.

Service visit to teach you how to use the appliance; correct the installation;
reset circuit breakers or replace home fuses

Repairs due to other than normal household use.

Damage caused from accident, abuse, alteration, misuse, incorrect installation
or installation not in accordance with local codes

Units installed in non-residential application such as day care centers, bed and
breakfast centers, churches, nursing homes, restaurants, hotels, schools, etc.

This warranty applies to vent hoods used in residential applications; it does
not cover their use in commercial situations.

This warranty is for products purchased and retained in the 50 states of the
U.S.A., the District of Columbia and Canada. This warranty applies even if you
should move during the warranty period. Should the appliance be sold by the
original purchaser during the warranty period, the new owner continues to be
protected until the expiration date of the original purchaserís warranty period.

This warranty gives you specific legal rights. You may also have other rights
which vary from state to state.

DCS Will Cover:

DCS Will Not Cover:

All manuals and user guides at all-guides.com

Summary of Contents for DCS-IVH-48

Page 1: ...Dynamic Cooking Systems Inc ISLAND VENT HOOD USE AND CARE INSTALLATION INSTRUCTIONS DCS IVH 48 DCS IVH 36 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...safe and enjoyable use To help serve you better please fill out and return the Ownership Registration Card and keep this Guide handy as it will help answer questions that may arise as you use your ne...

Page 3: ...ical Inspector s use INSTALLER Please leave these instructions with the unit for the owner OWNER Please retain these instructions for future reference Table of Contents Important Safety Instructions 2...

Page 4: ...maintain proper combustion and safe exhausting of gases through the flue chimney of fuel burning equipment Follow the cooking equipment manufacturers guideline and safety standards such as those publ...

Page 5: ...nience in mind Features include a high capacity variable speed blower with speed controller commercial style dishwasher safe filters easy to clean inside grease trays and four halogen lights with Hi L...

Page 6: ...being centered on the appliance Vertically the bottom of the hood should be between 30 36 above the appliance cooking surface DUCTING ducting transitions air must flow to outside use of Backdraft damp...

Page 7: ...48 DCS IVH 36 DCS IVH 36 VENT HOOD DIMENSIONS ntrol 30 12 TOP VIEW of DCS IVH 18 12 TOP VIEW of DCS IVH venting specs 7 venting specs 4 x18 rectangular Refer to venting specifications below when order...

Page 8: ...d 94 LBS for the DCS IVH 36 NOTE The soffit height will vary according to the ceiling height GENERAL INSTALLATION GUIDELINES 1 Determine the location for installation 2 Determine the centerline of the...

Page 9: ...NS GIVEN ARE FOR A 1 2 INCH DRYWALL 1 Create a soffit structure and attach the soffit brackets as in fig ure 1A Refer to the installation guidelines on Page 6 2 Attach the soffit support bars as shown...

Page 10: ...RDING TO CEILING HEIGHT 287 8 4 SOFFIT BRACKETS The dimensions given are for a 1 THE DIMENSIONS GIVEN ARE FOR A 1 2 INCH DRYWALL DUCT COVER 1 Create a soffit structure and attach the soffit brackets a...

Page 11: ...ffit brackets The dimensions given are for a 1 2 drywa THE DIMENSIONS GIVEN ARE FOR A 1 2 INCH DRYWALL DUCT COVER 3 After adequately securing the soffit structure to the ceiling joist attach the Islan...

Page 12: ...ct Cover NOTE Duct Cover height will vary according to ceiling height these must be custom built 6 Mounting Screws Solid Soffit Structure mounted to ceiling joices THE DIMENSIONS GIVEN ARE FOR A 1 2 I...

Page 13: ...nate duct sizes in rectangular style may be used If a rectangular duct style is used the duct must equal at least 78 6 In 2 for best results E Ex xa am mp pl le e 3 1 4 x 24 duct 78 In 2 Maintain cons...

Page 14: ...lights The switch controls the brightness of the lights with Hi Off Low Use only 50w Max Halogen Narrow Flood replacement bulbs Caution Halogen lamps are constructed of a glass bulb with a pressurized...

Page 15: ...stic non metal soap pads for cleaning or scouring use only soap pads with soap still in them a dry pad can scratch the surface 4 Be sure to rinse thoroughly and to wipe dry to avoid water marks Filter...

Page 16: ...e filter s by gently pulling up and out The grease trays can easily be reached once the filters are removed Grease collection trays are easily accessible at the center beneath the filter See illustrat...

Page 17: ...DCS IVH 48 DCS IVH 36 Island Vent Hood Wiring Diagram 15 All manuals and user guides at all guides com...

Page 18: ...mal household use Damage caused from accident abuse alteration misuse incorrect installation or installation not in accordance with local codes Units installed in non residential application such as d...

Page 19: ...ating the authorized service agency in your area please contact the DCS Consumer Service Department for an authorized service agent near you 888 281 5698 Your satisfaction is of the utmost importance...

Page 20: ...process at DCS we reserve the right to change specifications or design without notice Dynamic Cooking Systems Inc 5800 Skylab Road Huntington Beach CA 92647 Tel 714 372 7000 Fax 714 372 7001 Parts Cu...

Reviews: