INSTALLER FINAL CHECKLIST
15
GENERAL
Placement of unit.
Specified clearance maintained to cabinet surfaces.
Unit Level - front to back, side to side.
All packaging material and tie straps removed, drip pans clean and empty.
Backguard attached if there is less than 12" clearance above the cooking surface to combustibles
behind unit.
Radiant tray placed in grill unit (if equipped). The two grill racks in place.
ELECTRICAL
Receptacle with 15 ampere over-current protection is provided for service cord connection.
Adequate ground connection.
GAS SUPPLY
Connection: 1/2 NPT with a minimum 5/8" diameter metal flex line.
Site gas supply is compatible with cooktop model, & sufficient pressure is available
(see gas requirements pg. 12).
Manual gas shut-off valve installed in an accessible location.
Unit tested and free of gas leaks.
OPERATION
All internal packing materials removed. Check below grate, pans and drip drawers.
Grill compartment seated and does not rock (not all models).
Bezels centered on burner knobs and knobs turn freely.
Each burner lights satisfactorily, both individually and with other burners.
Flame adjustment made on air shutter of griddle, or grill burner, (figs. 10).
Griddle is level and does not rock (not all models).
Drip trays are properly in place and pull out freely (Not all models).
Burner grates correctly positioned, level, and do not rock.
Summary of Contents for CS-364G
Page 17: ...CS 36 48 WIRING DIAGRAM 16 17473 01 eps Rev A 08 02 ...
Page 18: ...CS 36 48 SCHEMATIC 17 17473 02 eps Rev A 08 02 ...
Page 19: ...CS 485 WIRING DIAGRAM 18 17473 03 eps Rev A 08 02 ...
Page 20: ...CS 485 SCHEMATIC 19 17473 04 eps Rev A 08 02 ...
Page 23: ...NOTES 22 ...
Page 24: ...NOTES 23 ...
Page 25: ...NOTES 24 ...