DCS BGA131 Use And Care Manual Download Page 12

11

LEAK TESTING & LIGHTING INSTRUCTIONS

WARNING:

Do not smoke while leak testing. Extinguish all open flames.

Make  a soap solution of one part liquid
detergent, and one part water. Never leak test
with an open flame. For LP units, check with a
full cylinder. Make sure all control valves are
in the “OFF” position. Turn the gas supply
“ON”. Check all connections from the supply
line (Fig. 02), or LP cylinder (Fig. 03) up to the
manifold pipe assembly (Fig. 06). Apply the
soap solution around the connection with a
spray bottle, brush, or rag. Soap bubbles will
appear where leak is present.

If a leak is

present, turn off gas supply, tighten any
leaking fittings, turn gas on, and recheck.

WARNING: IMPORTANT! 

Inspect the gas supply piping or hose prior to turning the gas “ON”. If there is
evidence of cuts, wear or abrasion, it must be replaced prior to use. Do not
use the Professional Side Burner if the odor of gas is present. Turn the control
knob to “OFF”, then turn on the gas supply. If using LP, is there gas in the
tank?  Always keep your face and body as far away from the burner as
possible when lighting.

LIGHTING INSTRUCTIONS

Remove the burner cover, or any cooking utensils from
the burner grate.

Push and turn the control knob

counterclockwise to the “HI” position. This will start the
gas flowing. Push and hold the ignition button next to
the burner knob. You’ll hear a snapping sound. At the
same time a spark will be provided at the burner
ignition. It may be necessary to engage the ignition
button until gas has filled the line. If the smell of gas is
detected and the ignition is not functioning,
immediately turn the control knob “OFF”.

Allow 5

minutes for any accumulated gas to dissipate, then see
the following section for “Match Lighting”.

REAR

FRONT

IGNITION

FIG. 07 BGA132-BI Shown

FIG.06

Ignition

Control
Knob

Summary of Contents for BGA131

Page 1: ...THE PROFESSIONAL SIDE BURNER Use and Care Guide MODELS BGA131 BGA132 BGA131 BI BGA132 BI...

Page 2: ...your convenience product questions can be answered by a DCS Customer Service Representative by phone 1 888 281 5698 Fax 714 372 7004 email support dcsappliances com or by mail DCS Attention Customer...

Page 3: ...k up 7 LP Tank Requirements 8 BUILT IN INSTALLATION FOR MODELS BGA131 BI BGA132 BI 9 CART INSTALLATION FOR MODELS BGA131 BGA132 10 LEAK TESTING AND LIGHTING INSTRUCTION Lighting Instructions 11 Match...

Page 4: ...r other such enclosed areas Keep the area surrounding the Professional Side Burner clear and free from combustible materials gasoline other flammable liquids or vapors charcoal lighter fluid and trash...

Page 5: ...Burner does not reach temperature 3 The Professional Side Burner heats unevenly 4 The burner s make popping noises Do not attempt to disconnect any gas connections while your burner is in use or the...

Page 6: ...as possible Locate the Side Burner only in a well ventilated area Never locate the Side Burner in a garage breezeway shed or other such enclosed areas GAS REQUIREMENTS Verify the type of gas supply to...

Page 7: ...al shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 kPa The installation of this appliance must conform with local codes...

Page 8: ...supplied gas valve in an accessible location LP GAS HOOK UP CONNECTION 1 2 NPT male with 3 8 flare adapter included OPERATING PRESSURE 10 0 W C Side Burner uses the LP regulator from adjoining grill A...

Page 9: ...only Do not change the regulator hose assembly from that supplied with the unit or attempt to use a Type 1 equipped regulator hose assembly with a standard 510 POL tank valve assembly The cylinder mus...

Page 10: ...ner Fig 04 It is recommended that ventilation holes are provided in the enclosure in the event of a gas leak The counter and supporting ledges or deck must be level and flat IMPORTANT Gas fittings reg...

Page 11: ...CART INSTALLATION FOR BGA131 BGA132 10 2 10 2 10 BGA131 BGA132 REAR FRONT IGNITION BURNER IGNITION 12 3 4 3 8 15 3 4 23 13 13 10 10 3 4 3 4 3 8 26 3 8 3 8...

Page 12: ...it must be replaced prior to use Do not use the Professional Side Burner if the odor of gas is present Turn the control knob to OFF then turn on the gas supply If using LP is there gas in the tank Al...

Page 13: ...essary Burner flames should be blue and stable with no yellow tips excessive noise or lifting Fig 09 If any of these conditions exist check that the air shutter or burner ports are not blocked If the...

Page 14: ...re are many different stainless steel cleaners available Always use the mildest cleaning procedure first scrubbing in the direction of the grain Do not use steel wool as it will scratch the surface To...

Page 15: ...s can be seen clear them using a wire coat hanger that has been straightened out ORIFICE CLEANING With the burner s removed shine a flashlight into the orifice to ensure that there is no blockage Use...

Page 16: ...ible Is the fuel hose bent or kinked Is there adequate gas supply available If it is only one burner of the dual burner unit that appears low does the orifice or burner need cleaning If using LP gas c...

Page 17: ...ATURAL 13005 49 ORIFICE LP 13005 56 10 OT ELECTRODE ASSEMBLY 30221 02 11 BATTERY IGNITION MODULE 18355 ITEM DESCRIPTION PART NO 12 1 5VDC BATTERY AAA 18356 13 CONTROL KNOB 14351 14 BEZEL 14006 PL 15 D...

Page 18: ...49 ORIFICE LP 13005 56 10 BEZEL 14006 PL 11 CONTROL KNOB 14351 ITEM DESCRIPTION PART NO 12 BATTERY IGNITION MODULE 18355 13 1 5VDC BATTERY AAA 18356 14 DRIP PAN HANDLEW A DBI BGA132 BI MODEL 33035 DR...

Page 19: ...SINGLE DOUBLE SIDE BURNER WIRING DIAGRAM 18 IGNITION SWITCH 18355 BATTERY IGNITION MODULE 1 5 VOLT ALKALINE BATTERY GND TERMINAL NOTE HIGH VOLTAGE AT TERMINALS...

Page 20: ...und by DCS to be defective Replacement will be F O B DCS DCS WILL NOT PAY FOR Correct the installation Instruct you how to use the equipment Repairs when the appliance is used on other than normal res...

Page 21: ...ef description of the problem Your satisfaction is of the utmost importance to us If a problem cannot be resolved to your satisfaction please write or fax or email us at Write DCS Attention Customer S...

Page 22: ...oduct improvement is an ongoing process at DCS we reserve the right to change specifications or design without notice 5800 Skylab Road Huntington Beach CA 92647 Tel 714 372 7000 Fax 714 372 7001 Custo...

Reviews: