PTT-24 Push-To-Talk 
Lockout Device   

          

                                  Front View

           

            

                                 Rear View

FEATURES

Use to de-key radios on Busy/Idle T1 trunks

Industrial temperature rated  -40 to +70 C

50 Telco amphenol in and out connectors

Push button switches to select control port

Toggle switch to select 12 or 24 E leads

Switch to test lockout function

The selected control port, when asserted, de-
asserts the other 11 or 23 E leads 

Audible alarm with audio shutoff button

Alarm input to force lockout function

Supports Tie Line Types I, II IV and V

1U high, 19” rackmount

-48 VDC dual power inputs, diode protected from 
each other

DESCRIPTION

The PTT-24 is a Push-to-Talk lockout device. It is 

used with multiple E&M circuits linked to radios. The PTT-24
solves the problem of radio transmitters being locked into a 
Transmit ON state when a T1 circuit fails. Many T1 trunk 
lines will go into a busy condition when the T1 trunk fails. 
This causes the E&M leads to lock in an ON state, which 
causes radio transmitters to lock in the ON state. 

12 or 24 E&M ports are wired through the PTT 

Lockout unit. A front panel toggle switch is used to select 12 
or 24 port operation. A 2 position push button switch is used 

to select the control port. The Power LED 
flashes if an invalid control port number is 
selected.

Based on the selected control port 

(via the front panel) the PTT Lockout 
device will detect a closure to ground on 
that port and de-assert all the other ports.
E&M Type III is not supported. 

In the PTT-24 12 port mode, 

selecting control channel 1 through 12 will 
select one of the even numbered leads 26 
though 48 as the control port. The other 11 
even numbered leads will be de-asserted if 
the control port is asserted. All other leads 
are passed straight through.

In the PTT-24 24 port mode, 

selecting control channel 1 through 24 will 
select one of the leads 26 though 48 as the 
control port. The other 23 leads will be de-
asserted if the control port is asserted. All 
other leads are passed straight through.

If the PTT-24 were to lose power, 

the E-leads will be in a pass through mode 
as though the PTT-24 is only a “lump in 
the cable”.

 Lockout can be triggered by the 

E&M control port being activated or the 
alarm input. For both the control port and 
the alarm input, there is a delay of 20 
milliseconds before the lockout occurs. The 
de-activation delay is 5 seconds. The de-
activation delay eliminates lockout 
“chattering” on/off/on/off, etc.
 

Leads 1 though 25 and 50 of the 50 

pin amphenol Telco connector are passed 
straight through. 