11
6.
SETUP
INTRODUCTION
Initial setup is performed using a PC with terminal emulation software (HyperTerm). After initial
configuration is complete, Telnet or a Web Browser may be used for further configuration and for
monitoring.
CONNECTIONS
Using the serial cable provided, connect the PC to the SETUP port on EST. Put DIP switch 2 in
the UP position. The SETUP port will remain active as long as switch 2 is in the UP position.
USING A PC
Set the PC terminal emulation software as follows:
Rate:
9600
Data Bits:
8
Stop Bits:
1
Parity:
None
Flow Control: None (disabled)
Apply power to the EST.
USING THE SETUP PORT
After the unit boots, press <Enter>. An
Enter name:
prompt should appear. Enter the user name
admin
. At the
Enter password:
prompt, press <Enter>. The following menu should appear.
Enter name: admin
Enter password:
---- Welcome to the EST-9600 version v1_00 Setup Program ----
1 Set Administration Values
2 Set HDLC Tunnel Values
3 Set Ethernet LAN Values
4 Set HDLC Port Values
5 Display Settings
6 Display Status
7 Reset Default Settings or Reset Unit
8 Save and Activate
9 Exit without Saving
Select a function by number ->:
Summary of Contents for EST-9600