![DCB BROADCAST POLLING FRAD BPF-2 BU Manual Download Page 15](http://html1.mh-extra.com/html/dcb/broadcast-polling-frad-bpf-2-bu/broadcast-polling-frad-bpf-2-bu_manual_4007388015.webp)
15
5.3
Using the Network Management port
To activate the NMP, press the ENTER key. When you see
AT
YOUR COMMAND >>
, the NMP is active and ready for your
commands. Type H <Enter> to display the command set.
5.4
Commands
5.4.1
Help (H or ?)
COMMAND
LOCAL
REMOTE PARAGRAPH
Show: Config
SC
RSC#
5.4.2
Port Map
SM
RSM#
5.4.3
FR Status
SS
RSS#
5.4.4
Change: Port Config
CP
RCP#
5.4.5
Port Map
CM
5.4.6
Delay Timeout CD
RCD#
5.4.7
FR Config
FR
5.4.8
Config Internal DSU
CN
5.4.9
Config Backup Modem
CBM
5.4.10
Config Backup Number CBN
5.4.11
Set ID
ID
RID#
5.4.12
Set Password
PW
5.4.13
Activity Counters/Zero
AC/Z
RAC#/RZ#
5.4.14
Test Tools
TT
5.4.18
Type
TY
RTY#
5.4.15
Repeat Last Command
*
5.4.16
Disconnect NMP
BYE
5.4.17
This Help screen shows the choice of commands available. The
commands allow you to display the selected options, configure the
BPF-BU, and perform many different diagnostic functions. The #
character in the remote commands represents the DLCI number of
the Host BPF unit and must be included with the command.
5.4.2
Show (Port) Configuration
The Show Config (SC) command shows the current port configuration
settings for either the local or the remote (RSC#) ports. Port numbers
may be included with this command to limit the display range. If no
port numbers are included, settings for all ports are shown. Use this
command to verify proper port configuration.