![DC Matic TL-900 User Manual Download Page 5](http://html1.mh-extra.com/html/dc-matic/tl-900/tl-900_user-manual_3981274005.webp)
Fig. 5
Properly Controlling Output Impacting Torque
DC-Matic Enterprises, Inc. markets (4) individual 3/4 inch drive “torque limiting
extensions” calibrated at 175, 250, 350 and 475 foot pounds. When attached to the
Model TL-900
a burst of (2) seconds of tool run time will yield an output (impacting
torque) limited within the range (plus or minus 10 %) that is marked on the extension. It
must be noted that a longer than (2) second burst will yield a greater amount of
impacting torque.
WARNING
Excluding the do-it-yourself replacement of motor
brushes, please
DO NOT
attempt to repair your
Model TL-900.
Doing so will void the tool’s WARRANTY.
Fig. 6
475 Foot Pound
Torque Limiting Extension
By removing the (4) allen-head cap screws
that secure the hammer assembly to the
tool, the stabilizing handle can be moved
to the other side as shown.
Stabilizing Handle Placement
5
www.dcmatic.com