DBZ DMi 2/2000A User Manual Download Page 9

1

.

Thermal Breaker

     

The power amplifier will disconnect the AC power supply in the event of an overload condition. 

      Pressing the reset lever after the fault is released,  it will restore the operation (reusable).

2

.

Power Cable

   

Plug into AC power socket.

3.Signal In LINK

   

LINK Input Connector(Pin 1=Ground/Pin 2=+/Pin 3=- )

.

4.Signal In

  

 

XLR Input Connector: 

      1) Balance input: Pin 1=Ground/Pin 2=+/Pin 3=-  (according to standard IEC 268)
      2) un-balance input: Pin 1/3=Ground/Pin 2=+

5.Speakon Output Connector

   

Stereo/Parallel Mode:

   

Speakon1 1 + / 1 -  Respectively Connect the positive (+) / negative (-) terminals of speaker 1.

     Speakon1 2 + / 2 -  Respectively Connect the positive (+) / negative (-) terminals of speaker 2.
     Speakon2 1 + / 1 -  Respectively Connect the positive (+) / negative (-) terminals of speaker 2.
     Speakon2 2 + / 2 -  Idle.
     Bridge Mode

   

Speakon1 1 + / 2-  Respectively Connect the positive (+) / negative (-) terminals of speaker 2.

6

.

Binding Post Connector

   

Stereo/Parallel Mode

:

    

Channel 1 red (+) / black (-)  Binding posts are connected respectively to the positive (+) / 

       negative (-) terminals of speaker 1.
       Channel 2 red (+) / black (-)  Binding posts are connected respectively to the positive (+) / 
       negative (-) terminals of speaker 1.

    

Bridged Mode

:

    

Channel 1 red (+) Binding post connected to the positive (+) terminals of speaker and 

       Channel 2 black(-) Binding post connected to the negative(-) terminals of spaker.

7.Fan Outlet

  

The fan draws air from the chassis.

8.Input Sensitivity Switch

    

0

.

775V

(

0dBu

)/

1V

(

0dBv

) /

32dB

 

Threes input gain choices.

9.Working Mode Switch

   

  1.Stereo: CH1-2 Function Independent work and control.

   

2

.

Parallel: 1)Input signal to CH1, CH1 is paralleled with CH2, CH1 and CH2 are controlled 

                             independently, now CH2 input is invalid. 
     3

.

Bridged: 1) Input signal to CH1, signal through CH1 will access CH2 in reverse phase, 

                             The volume of CH1 can control CH2 at the same time. CH1 Output and CH2 
                             Output connect with Speaker in series.

10

.

Earthing Switch

    

When the switch is turned ON (AC ground), the ground switch is on (AC-DC ground), signal ground 

    selection --- The audio system noise can be suppressed by grounding switch.

 

Note: The output of all amplifiers will produce high voltage. Live installation is not allowed. There shouldn't be any 
          excess bare copper exposed between the speaker cable and the amplifier binding posts. In addition, please do 
          not ground the amplifier output, or access to any other amplifier input or output. Please use high-quality speaker 
          connector and speakers dedicated cable, and minimize the power amplifier and speaker connection cable.

Rear Panel Introduction

7

1

3

4

2

5

9

8

10

6

7

8A
Circuit breaker

AC 220V 1050W

LINK

LINK

INPUT

CH1

CH2

XLR: 1=   

/

2=+

/

3=-

OUTPUT

CH1+/-=1+/-
CH2+/-=2+/-
BRG+/-=1+/2-

CH2+/-=1+/-
2+/-=NOT USED

SENSITIVITY

GROUND

MODE

0.775V

1.0V

32dB

STEREO

PARALLEL

BRIDGE

ON

OFF

CH1

Ch2

BRG

Summary of Contents for DMi 2/2000A

Page 1: ...User Manual s DMi 4 2500A DMi 4 3500A DMi 2 2000A DMi 2 3000A DMi 2 4000A Professional Power Amplifier...

Page 2: ......

Page 3: ...tion Diagram 10 Speakon Connection socket 10 Speakon Connector 10 Connection Mode Introduction 11 12 Bridge Mode 11 12 Parallel Mode 11 12 Stereo Mode 11 12 Detailed Specifications PROT indicator long...

Page 4: ...the unit cover Otherwise it may cause electric shock If it is deemed necessary to repair service or repair the product contact the factory Do not modify this unit Otherwise it may cause a fire or elec...

Page 5: ...ficient air flow the internal temperature of the power amplifier may rise and may cause a fire To mount several of the power amplifier on a standard EIA stand please refer to the installation instruct...

Page 6: ...t affected by the electromagnetic of transformer Protection System It has multiple protection features such as output short circuit protection overload protection DC protection VHF protection output v...

Page 7: ...CH1 and CH2 5 CH2 Volume Knob Input signal attenuator in stereo and parallel mode they control the volume of the corresponding channel when bridged CH2 volume knob is idle and not controlled 6 Functi...

Page 8: ...controlled 4 3 CH3 Volume Knob Input signal attenuator in stereo and parallel mode they control the volume of the corresponding channel when bridged CH3 will control the volume of the two channels CH3...

Page 9: ...st connected to the negative terminals of spaker 7 Fan Outlet The fan draws air from the chassis 8 Input Sensitivity Switch 0 775V 0dBu 1V 0dBv 32dB Threes input gain choices 9 Working Mode Switch 1 S...

Page 10: ...peaker 4 Speakon4 2 2 Idle Bridge Mode Speakon1 1 2 Respectively Connect the positive negative terminals of speaker 2 Speakon3 1 2 Respectively Connect the positive negative terminals of speaker 2 6 I...

Page 11: ...ls of speaker and Channel 2 black Binding post connected to the negative terminals of speaker Channel 3 red Binding post connected to the positive terminals of speaker and Channel 4 black Binding post...

Page 12: ...cable peel off the 15mm long insulation and place the bare wire through the appropriate binding post of the speaker Tighten the posts until they grip the wire firmly Refer to the socket for the polari...

Page 13: ...ker impedance varies depending on the connection method and the connected speaker parameters Be sure that the speaker impedance is not lower than the lowest value shown below Bridge Mode If the amplif...

Page 14: ...channel 1 and the negative pole of channel 2 The bridge output is doubling the output voltage Connect the speakers as shown below Note that the speaker impedance varies depending on the connection met...

Page 15: ...working temperature is also suggested below 35 Due to lots of dust in construction environment there might be much dust in filter sponge blocking wind path It s advised to clean sponge with high power...

Page 16: ...1 2 Rated Output Power 98dB 200 1 kHz and below 70dB 1 kHz and below 20K 10K balanced Unbalanced front to rear airflow 0 775V 1V 32dB Soft start DC short circuit clip limit over heat temperature rise...

Page 17: ...Soft start VHF DC short circuit clip limit over heat progressive volume Working state voltage CLIP SIG ON LCD screen Front panel indicator 680Wx4 1100W x4 2200W x2 1300W x4 Stereo Parallel Bridge Gai...

Page 18: ...djust the pre amp processor Signal cable or speaker cable connection abnormal Mode switch is not toggled in place ___ When the signal light is normal please check the speaker cables Mode switch Check...

Page 19: ...the user replaces any part of the machine by himself C The serial number is altered or tore up the warranty label D Negligent use water or other objects are getting into the machine and cause damage E...