background image

WARNING FOR YOUR PROTECTION

READ THE FOLLOWING:

KEEP THESE INSTRUCTIONS

HEED ALL WARNINGS

FOLLOW ALL INSTRUCTIONS

THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING 

LIQUID AND NO OBJECT FILLED WITHI LIQUID, SUCH AS VASES, SHALL 

BE PLACED ON THE APPARATUS.

CLEAN ONLY WITH A DRY CLOTH.

DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN AC-

CORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.

DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS, 

HEAT REGISTERS, STOVES, OR OTHER APPARATUS (INCLUDING AMPLI-

FIERS) THAT PRODUCE HEAT.

ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE MANUFAC-

TURER.

UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN 

UNUSED FOR LONG PERIODS OF TIME.

Do not defeat the safety purpose of the polarized or grounding-type plug.  A 

polarized plug has two blades with one wider than the other.  A grounding 

type plug has two blades and a third grounding prong.  The wide blade or third 

prong are provided for your safety.  If the provided plug does not fit your out-

let, consult an electrician for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly at plugs, 

convenience receptacles, and the point where they exit from the apparatus.

Use only with the cart stand, tripod bracket, or table specified by the manufac-

ture, or sold with the apparatus.  When a cart is used, use caution when moving 

the cart/apparatus combination to avoid injury from tip-over.

Refer all servicing to qualified service personnel.  Servicing is required when 

the apparatus has been damaged in any way, such as power-supply cord or plug 

is damaged, liquid has been spilled or objects have fallen into the apparatus, the 

apparatus has been exposed to rain or moisture, does not operate normally, or 

has been dropped.

POWER ON/OFF SWITCH: If the equipment has a Power switch, the Power 

switch used in this piece of equipment DOES NOT break the connection from 

the mains.

MAINS DISCONNECT:  The plug shall remain readily operable.  For rack-

mount or installation where plug is not accessible, an all-pole mains switch with 

a contact separation of at least 3 mm in each pole shall be incorporated into 

the electrical installation of the rack or building.

FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE RECEP-

TACLE:    Replace fuse with same type and rating only.

MULTIPLE-INPUT VOLTAGE: This equipment may require the use of a different 

line cord, attachment plug, or both, depending on the available power source at 

installation. Connect this equipment only to the power source indicated on the 

equipment rear panel. To reduce the risk of fire or electric shock, refer servic-

ing to qualified service personnel or equivalent.

If connected to 240V supply, a suitable CSA/UL certified power cord shall be 

used for this supply.

SAFETY INSTRUCTIONS 

NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.

WARNING: THIS APPLIANCE SHALL  BE  CONNECTED  TO  A  MAINS  SOCKET  OUTLET  WITH  A 

PROTECTIVE EARTHING CONNECTION.

The cores in the mains lead are coloured in accordance with the following code:

GREEN and YELLOW - Earth        BLUE - Neutral        BROWN - Live

As colours of the cores in the mains lead of this appliance may not correspond with the coloured 

markings identifying the terminals in your plug, proceed as follows:

U

  The core which is coloured green and yellow must be connected to the terminal in the plug 

marked with the letter E, or with the earth symbol, or coloured green, or green and yellow.

U

  The core which is coloured blue must be connected to the terminal marked N or coloured 

black.

U

  The core which is coloured brown must be connected to the terminal marked L or coloured 

red.

 

This equipment may require the use of a different line cord, attachment plug, or both, depending 

on the available power source at installation.  If the attachment plug needs to be changed, refer 

servicing to qualified service personnel who should refer to the table below. The green/yellow 

wire shall be connected directly to the units chassis.

CONDUCTOR

WIRE COLOR

Normal

Alt

L

LIVE

BROWN

BLACK

N

NEUTRAL

BLUE

WHITE

E

EARTH GND

GREEN/

YEL

GREEN

WARNING: 

If the ground is defeated, certain fault conditions in the unit or in the system to 

which it is connected can result in full line voltage between chassis and earth ground. Severe 

injury or death can then result if the chassis and earth ground are touched simultaneously.

The symbols shown above are internationally accepted symbols that warn of 

potential hazards with electrical products. The lightning flash with arrowpoint in 

an equilateral triangle means that there are dangerous voltages present within 

the unit. The exclamation point in an equilateral triangle indicates that it is 

necessary for the user to refer to the owner’s manual.

These symbols warn that there are no user serviceable parts inside the unit. 

Do not open the unit. Do not attempt to service the unit yourself. Refer all 

servicing to qualified personnel. Opening the chassis for any reason will void 

the manufacturer’s warranty. Do not get the unit wet. If liquid is spilled on the 

unit, shut it off immediately and take it to a dealer for service.  Disconnect the 

unit during storms to prevent damage.

IMPORTANT SAFETY INFORMATION

Summary of Contents for 166xs

Page 1: ...User Manual UAL OMPRESSORÉ ÌiÀ ATE Professional Audio Equipment ...

Page 2: ...ent only to the power source indicated on the equipment rear panel To reduce the risk of fire or electric shock refer servic ing to qualified service personnel or equivalent If connected to 240V supply a suitable CSA UL certified power cord shall be used for this supply SAFETY INSTRUCTIONS NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER CORD WARNING THIS APPLIANCE SHALL BE CONNECTED TO ...

Page 3: ...device may not cause harmful interference and UÊ this device must accept any interference received including interference that may cause undesired operation Operation of this unit within significant electromagnetic fields should be avoided UÊ use only shielded interconnecting cables U K MAINS PLUG WARNING A molded mains plug that has been cut off from the cord is unsafe Discard the mains plug at a...

Page 4: ...ction 3 Making Connections 10 3 1 Basic Connections 10 3 2 Specific System Connections 11 3 3 Installation Considerations 12 Section 4 Operating Notes 14 4 1 Expander Gate Applications 14 4 2 Basic Compressor Applications 15 Section 5 TechnicalSupport FactoryService 21 Section A Appendix 22 A 1 Technical Specifications 22 A 2 Wiring Diagrams 23 dbx 166xs Table of Contents ...

Page 5: ... the sound s PeakStop Limiting provides control of maximum peak levels at the output of the 166xs regardless of any other control PeakStop comes after the compression gating and other circuitry including the output gain so it sets an absolute limit for peak excursions before they reach the output s True RMS Level Detection senses the power in the program in a musical manner much the same as human ...

Page 6: ...ctory for service you MUST first contact Technical Support to obtain a Return Authorization Number No returned products will be accepted at the factory without a Return Authorization Number Please refer to the Warranty information on the following page which extends to the first end user After expiration of the warranty a reasonable charge will be made for parts labor and packing if you choose to ...

Page 7: ...returned to dbx WITH RETURN AUTHORIZATION from the factory where all parts and labor will be covered up to a period of two years A Return Authorization number must first be obtained from dbx The company shall not be liable for any consequential damage as a result of the product s use in any circuit or assembly 4 dbx reserves the right to make changes in design or make additions to or improvements ...

Page 8: ...ne input jack should be used at a time except for splitter applications where one input jack is used as an input and the other input jack is used as an output see Using the SIDECHAIN INSERT section on page 10 Since a given pair of channel input jacks e g Channel 1 XLR INPUT and Channel 1 1 4 INPUT are internally connected TIP Pin 2 RING Pin 3 SLEEVE Pin 1 if one of the jacks is unbalanced then the...

Page 9: ...NPUT jack at an impedance of 2k The TIP acts as a Return for equipment to feed the 166xs detector circuitry such as an equalizer for de essing or frequency sensitive gating compression You can also drive the 166xs SIDECHAIN INSERT with the output of most equipment by using a 1 4 mono phone plug Input impedance is greater than 10kΩ NOTE When a cable is plugged into this jack it automatically breaks...

Page 10: ...dent The CONTOUR LED turns On when the CONTOUR button is depressed COMPRESSOR Section GAIN REDUCTION Meter This meter displays how much the signal is being attenuated by the compressor and the gate Compressor THRESHOLD LEDs These three LEDs indicate the relationship of the input signal level to the threshold of compression The green BELOW LED is On when the signal is below threshold and the red AB...

Page 11: ... threshold When an input signal is above the THRESHOLD reference level the setting of this control determines the number of decibels dB by which the input signal must change in level to produce a 1dB increase in the signal level at the output of the 166xs A setting of 2 1 indicates an input output ratio wherein a 2dB increase in signal above threshold will produce a 1dB increase in output signal A...

Page 12: ...with the threshold of compression The OUTPUT GAIN control is especially useful to compensate for the RMS level decrease which results from the 166xs dynamic processing effects After you adjust the 166xs controls for the desired amount of compression and gating set the OUTPUT GAIN to add the same amount of gain that is shown on the GAIN REDUCTION meters For example if the average amount of gain red...

Page 13: ...ible to allow the rounding to occur Therefore for applications where you must not exceed a given ceiling set the PEAKSTOP control 1dB to 2dB below the ceiling The PEAKSTOP LED illuminates whenever peaks attempt to exceed PeakStop level and are reduced in amplitude If the PeakStop LED illuminates when the PEAKSTOP LEVEL control is set to 20dBu the headroom capabilities of the 166xs are being exceed...

Page 14: ...eyboard mixer as the signal is sent to main mixer between a DAT s output and an analog cassette input When using a chain of processors the 166xs may be placed either before or after effects or dynamic processors However if you are using the 166xs for speaker protection the compressor should be as close to the amplifier as possible in the signal chain We recommend you use common sense and experimen...

Page 15: ...d or not or the 166xs INPUT and OUTPUT can be wired to an Insert point In the latter case the signals will most likely be unbalanced It is important to note that the amount of compression is directly related to the level of the input signal However depending upon your system s setup it may not always be clear as to what volume controls in your chain affect input level and which affect output level...

Page 16: ...in 2 or 3 or the ring of a 1 4 stereo phone jack Note that grounding pin 2 of the XLR jack reverses the phase through the 166xs Sound Reinforcement To compress a live mix or to protect loudspeakers connect the 166xs between the source mixing board or distribution amp and the power amp s If multi way loudspeakers with low level electronic crossovers are used the 166xs s should go after the crossove...

Page 17: ...g a 600Ω load The phone jack TIP connection is internally wired to the XLR pin 2 the RING is wired to pin 3 and the SLEEVE shield is wired to pin 1 Note that pins 2 and 3 are the reverse of certain older dbx and other manufacturer s equipment but if the same connection is used at both the input and the output the signal will be correctly polarized in phase 166xs SIGNAL FLOW Figure 3 Signal Flow Ba...

Page 18: ...itial transient set the RELEASE control slow enough to allow the gate to remain open and capture the signal s entire envelope The gate can also be used to dry up a track or mix that has too much reverb or ambience Set the RELEASE control so that the natural decay of the sound is somewhat truncated Changing Sound Quality The 166xs gate can effectively change the sonic character of a sound because i...

Page 19: ...LEASE times To compress a mix begin with a low RATIO setting THRESHOLD set for a few dB of Gain Reduction and SLOW Attack and Release OVEREASY and CONTOUR buttons In Smoothing Out Variations in Microphone Levels Variations in signal level can occur when the distance between a vocalist and a mic changes or when the dynamics of a voice changes relative to a vocalist s range To smooth out these varia...

Page 20: ... mode the 166xs takes slightly longer to react than in Hard Knee mode and will therefore emphasize the slap at the beginning of the note and reduce the boominess of its body The 166xs also works well for tightening snare drums and tom toms and can be used with drum machines to effectively alter the character of any electronic drum sound Cymbals and tom toms can be effectively compressed using the ...

Page 21: ...g levels compression can prevent recording levels e g cymbal tracks in a final mix or drum kit submix from saturating tape tracks see frequency weighted compression on page 18 Preventing Digital Overload Digital recorders and samplers produce audible distortion when they exceed their headroom i e the range above their maximum operating level The 166xs effectively ensures that audio input does not ...

Page 22: ...g Your EQ to Reduce Feedback in Live Settings Indoor and Outdoor Concerts Churches You can use your 166xs and EQ equalizer to reduce feedback in clubs churches outdoor concerts and other live settings Patch or insert the 166xs into the main output of a mixer set the 166xs to Hard Knee mode and slowly increase OUTPUT GAIN until the first feedback ring occurs then set up the 166xs with its RATIO at ...

Page 23: ...pping the equalizer bands causes any sound with dominant energy in the affected register to pull the level up because the 166xs will detect a need for less compression De Essing To apply de essing to vocals i e a reduction of sibilance use a parametric equalizer in the SIDECHAIN circuit and set it to boost the specific frequency range where the vocal hiss or lisp occurs generally in the 4kHz 6kHz ...

Page 24: ...obtained with an equalizer as previously described Those frequencies passed by the filter are subject to compression or at least they are subject to considerably more compression than those frequencies outside the passband Because a passive filter can have insertion loss it may be necessary to lower the 166xs THRESHOLD setting to maintain a given amount of gain reduction within the filter passband...

Page 25: ...ur Limited Two Year Standard Warranty which extends to the first end user After the warranty expires a reasonable charge will be made for parts labor and packing if you choose to use the factory service facility In all cases you are responsible for transportation charges to the factory dbx will pay return shipping if the unit is still under warranty Shipping Instructions Use the original packing m...

Page 26: ...mpression Up to 40dB 1kHz SMPTE IMD Typically 0 08 10dBu 15dB Gain reduction COMPRESSOR Threshold Range 40dBu to 20dBu Threshold Characteristic Selectable OverEasy or Hard Knee Compression Ratio Variable 1 1 to Infinity 1 60dB Maximum Compression Attack Time Variable program dependent 3ms to 340ms for 15dB gain reduction Release Rate Variable program dependent 200dB Sec to 3dB Sec EXPANDER GATE Th...

Page 27: ... TYPE MALE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEV...

Page 28: ... 4PVUI 4BOEZ 1BSLXBZ r 4BOEZ 6UBI 1IPOF r BY Int l Fax 801 568 7583 Questions or comments Contact us at www dbxpro com Printed in China 18 0807 A ...

Reviews: