2.12  COMPATIBILITY OF COMPONENTS:

 Unless otherwise noted, Capital Safety equipment is designed for use 

with Capital Safety approved components and subsystems only. Substitutions or replacements made with non 

approved components or subsystems may jeopardize compatibility of equipment and may affect safety and 

reliability of the complete system:

Horizontal Systems - In applications where an SRL is used in conjunction with a horizontal system (i.e.

horizontal I-beams and trolleys), the SRL and horizontal system components must be compatible.

Retrieval Systems - When using DBI-SALA SRLs with optional retrieval system, ensure the support

structure (i.e. tripod, davit arm) is compatible with connection of the SRL, and compatible with the

operation, stability, and strength of the SRL (see Figures 5 and 6).

IMPORTANT:

 Read and follow manufacturer’s instructions for associated components and subsystems in 

your personal fall arrest system.

2.13  COMPATIBILITY OF CONNECTORS:

 Connectors are considered to be compatible with connecting 

elements when they have been designed to work together in such a way that their sizes and shapes do not 

cause their gate mechanisms to inadvertently open regardless of how they become oriented. Connectors 

(hooks, carabiners, and D-rings) must be capable of supporting at least 5,000 lbs. (22 kN). Connectors 

must be compatible with the anchorage or other system components. Do not use equipment that is not 

compatible. Non-compatible connectors may unintentionally disengage (see Figure 3). Connectors must 

be compatible in size, shape, and strength. Self-locking snap hooks and carabiners are required by ANSI 

Z359.1 and OSHA.

2.14 MAKING CONNECTIONS:

 Use only self-locking snap hooks and carabiners with this equipment. Only use 

connectors that are suitable to each application. Ensure all connections are compatible in size, shape and 

strength. Do not use equipment that is not compatible. Ensure all connectors are fully closed and locked.

 

 

DBI-SALA connectors (snap hooks and carabiners) are designed to be used only as speci

fi

 ed in each 

product’s user’s instructions. See Figure 4 for illustration of the inappropriate connections stated below. 

DBI-SALA snap hooks and carabiners should not be connected:
A.  To a D-ring to which another connector is attached.

B.  In a manner that would result in a load on the gate.

C.  In a false engagement, where features that protrude from the snap hook or carabiner catch on the 

anchor and without visual con

fi

 rmation seems to be fully engaged to the anchor point.

D.  To each other.

E.  Directly to webbing or rope lanyard or tie-back (unless the manufacturer’s instructions for both the 

lanyard and connector speci

fi

 cally allow such a connection).

F.  To any object which is shaped or dimensioned such that the snap hook or carabiner will not close and 

lock, or that roll-out could occur.

NOTE:

 Other than 3,600 lb. (16 kN) gated hooks, large throat opening snap hooks should not be connected 

to standard size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists 

or rotates. Large throat snap hooks are designed for use on 

fi

 xed structural elements such as rebar or cross 

members that are not shaped in a way that can capture the gate of the hook.

Figure 3 - Unintentional Disengagement (Rollout)

If the connecting element to which a snap hook (shown) or carabiner 

attaches is undersized or irregular in shape, a situation could occur 

where the connecting element applies a force to the gate of the snap 

hook or carabiner. This force may cause the gate (of either a self-

locking or a non-locking snap hook) to open, allowing the snap hook 

or carabiner to disengage from the connecting point.

Small ring or other 

non-compatibly 

shaped element

7.

Force is applied

to the Snap

Hook.

8.

The 

Gate

presses against

the Connecting

Ring.

9.

The Gate opens

allowing the

Snap Hook to

slip off.

Figure 4 - Inappropriate Connections

netzerotools.com

netzerotools.com

netzerotools.com

netzerotools.com

Summary of Contents for Sealed-Blok 3400860

Page 1: ... protection and worker mobility in a sealed enclosure designed to keep critical components free of dirt grease water and chemicals See Figure 1 for available Sealed Blok SRL models and features Figure 1 Sealed Blok Self Retracting Lifelines A Anchorage Handle B Instruction Label C Housing D ID Label E Cable Guide F Lifeline G Bumper H Self Locking Snap Hook Sealed Blok SRL MODEL DESCRIPTIONS See i...

Page 2: ...ealed Blok Self Retracting Lifeline 130 Ft DBI SALA 3400407 Sealed Blok Self Retracting Lifeline 130 Ft DBI SALA 3400924 Sealed Blok Self Retracting Lifeline 50 Ft DBI SALA 3400967 Sealed Blok Self Retracting Lifeline 130 Ft DBI SALA 3400924 Sealed Blok Self Retracting Lifeline 50 Ft DBI SALA 3400965 Sealed Blok Self Retracting Lifeline 130 Ft DBI SALA 3400852 Sealed Blok Self Retracting Lifeline ...

Page 3: ...d the consequences of improper use 2 0 SYSTEM LIMITATIONS REQUIREMENTS Always consider the following limitations requirements when installing or using this equipment 2 1 CAPACITY Sealed Blok SRLs are designed for use by persons with a combined weight person clothing tools etc of 75 lbs to 310 lbs per ANSI Z359 Some units have a capacity of 420 lbs per OSHA Refer to the instruction label to determi...

Page 4: ...y before proceeding Figure 2 Fall Clearance and Swing Falls Swing Fall Hazard 6 ft 1 8 m Minimum Working Level Lower Level Working Distance from Anchorage 80 ft 24 m 70 ft 21 m 60 ft 18 m 50 ft 15 m 40 ft 12 m 30 ft 9 m 20 ft 6 m 10 ft 3 m 0 0 10 ft 3 m 20 ft 6 m 40 ft 12 m 30 ft 9 m H Height of the SRL D Distance Person Can Move Horizontally EXAMPLE If the worker is 40 ft 12 m directly below the ...

Page 5: ...ent that is not compatible Ensure all connectors are fully closed and locked DBI SALA connectors snap hooks and carabiners are designed to be used only as specified in each product s user s instructions See Figure 4 for illustration of the inappropriate connections stated below DBI SALA snap hooks and carabiners should not be connected A To a D ring to which another connector is attached B In a ma...

Page 6: ...e subsystem and component combinations may interfere with the operation of this equipment Use caution when using this equipment around moving machinery electrical hazards chemical hazards and sharp edges Do not loop the lifeline around small structural members WARNING Consult your doctor if there is reason to doubt your fitness to safely absorb the shock from a fall arrest Age and fitness seriousl...

Page 7: ... conditions it may be necessary to restrain the free end of the tag line to prevent interference and entanglement with equipment or machinery 4 6 RETRIEVAL AND RSQ CONTROLLED DESCENT The Sealed Blok SRL can be purchased with optional Retrieval and RSQ Controlled Descent features that allow use of the SRL for self rescue RSQ assisted rescue Retrieval or RSQ and lifting and lowering of materials Ret...

Page 8: ...sing for distortion cracks or other damage X X X Lifeline should pull out and retract fully without hesitation or creating a slack line condition X X X Ensure device locks up when lifeline is jerked sharply Lockup should be positive with no slipping RSQ mode X X X The labels must be present and fully legible See Section 8 X X X Look for signs of corrosion on the entire unit X X X Connecting Hook I...

Page 9: ...eline Avoid lifeline contact with sharp or abrasive surfaces Inspect lifeline frequently for cuts fraying burns or signs of chemical damage Dirt contaminants and water can lower dielectric properties of the lifeline Use caution near power lines Inspect each system component or subsystem according to manufacturer s instructions Record inspection results in the inspection log found in section 9 0 5 ...

Page 10: ...3400860 3400863 15 2 x 12 0 x 7 0 43 6 lbs 19 8 Kg 85 feet of 3 16 inch galvanized wire rope self locking plated steel swiveling snap hook with indicator 3400861 3400864 15 2 x 12 0 x 7 0 43 6 lbs 19 8 Kg 85 feet of 3 16 inch stainless wire rope self locking plated steel swiveling snap hook with indicator 3400862 3400865 15 2 x 12 0 x 7 0 43 6 lbs 19 8 Kg 85 feet of 3 16 inch stainless wire rope s...

Page 11: ...minum Cable Bumper Urethane Housing Cover Stainless Steel Anchorage Handle Stainless Steel Fasteners Stainless Steel Main Shaft Stainless Steel Locking Pawls Stainless Steel Ratchet Center Carbon Steel Motor Spring Stainless Steel Finish Paint Polyester Baked finish Swivel Assembly Stainless Steel Connecting Hook Plated Steel Forged Alloy Steel Connecting Hook Stainless Steel Stainless Steel netze...

Page 12: ...Length Label Front Label 1 Identification Label 8 2 ANSI MODELS 1 Housing Labels 8 3 CSA MODELS 1 Housing Labels 1 Replace label if it is not securely attached and fully legible netzerotools com netzerotools com netzerotools com netzerotools com ...

Page 13: ...D CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By netzerotools com netzerotools com netzerotools com netzerotools com ...

Page 14: ...ed By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By netzerotools com netzerotools com netzerotools com netzerotools com ...

Page 15: ...netzerotools com netzerotools com netzerotools com netzerotools com ...

Page 16: ...SCENT 50 feet of 3 16 inch stainless wire rope self locking plated steel swiveling snap hook with indicator 3400932 3400932C SEALED SELF RETRACTING LIFELINE WITH RSQ CONTROLLED DESCENT 50 feet of 3 16 inch stainless wire rope self locking stainless steel swiveling snap hook with indicator 3400940 3400940C SEALED SELF RETRACTING LIFELINE WITH RSQ CONTROLLED DESCENT AND RETRIEVAL 50 feet of 3 16 inc...

Page 17: ...crease the scope of this warranty CAPITAL SAFETY will not accept liability for defects that are the result of product abuse misuse alteration or modification or for defects that are due to a failure to install maintain or use the product in accordance with the manufacturer s instructions CAPITAL SAFETY S WARRANTY APPLIES ONLY TO THE END USER THIS WARRANTY IS THE ONLY WARRANTY APPLICABLE TO OUR PRO...