Mozart series calibrating procedure
14 /19
Fig. 17 – 30W RF module RT1 adjust
Table with R22 and R36 and Q3 values for each Mozart model.
R22
R36
Q3 drain
Mozart 30
100mV 20mV 26,5V
Mozart 50
80mV / 18.5V
Mozart 150
5mV 2,5mV 18,5V
Mozart 300
10mV 5mV 18,5V
Mozart 500
20mV 10mV 18,5V
Mozart 1000
20mV 10mV 18,5V
d)
Press RF ON/OFF button on the front panel to disable the RF and switch off the amplifier.
e)
Disconnect the amper-meter and reconnect the power cables to the RF amplifier module.
At this point the RF Power modules were calibrated successfully.