DB Drive OKUR A775.4 User Manual Download Page 5

3-1. MOUNTING PREPARATION

Disconnect the negative (   ) battery cable before mounting your OKUR amplifier or making any connections. 

Check the battery and alternator ground (   ) connections. 

Make sure they are properly connected and Free of corrosion before selecting a mounting location. 

Please take some concerns into consideration with cooling efficiency and safety.

3-2. MOUNTING PREPARATION

The OKUR amplifier uses a specially designed  heat radiation heatsink to avoiding excessive heat from 

OKUR circuitry.

But for better heat disipitation, It is good to find the mounting location where you can install 

OKUR vertically with the heatsink fins and better air flow around heat sink.

For the safety, you have to find dry and well ventilated location and make sure any cables 

and drilling car equipment are not interfaced with mounting location. 

Be sure the mounting location and drilling of pilot cables will not present a hazard to any cables, 

control cables, fuel lines, Fuel tanks, hydraulic lines or other vehicle systems or components.

3-3. +12V, GND, REM CONNECTION 

12V ( POWER CONNECTION )

Before mounting Platinum series, disconnect the negative (   ) wire from  battery to protect 

any accidentIal damage to amplifier and audio system.

A7

75.4 , 

A7

125.4, 

A7

300.2 ,

A7

750.1 ,

A7

1100.1 and 

A7

1500.1 are designed to use minimum 4 gauge power 

and ground cables 

A7

2000.1, 

A7

2500.1,  are designed to use minimum 0 gauge cables.

Connect the power cables to power terminal labeled as + 12V.

A7

75.4 , 

A7

125.4, 

A7

300.2, 

A7

750.1 ,

A7

1100.1 and 

A7

1500.1 have built-in fuses.

A72000.1, and  A72500.1 are not euipped with fuses so you need to install external

fuses.

In order to install external fuses, connect one end of fuse holder to the power cable and the other end 

of fuse holder to positive battery within 18in of the same cable gauge.

This fuse location will protect the system and the vehicle against the possibility of a short circuit 

in the power cable. 

Be sure to use fuses and fuse holder adequate for the current draw application

GND ( GROUND CONNECTION )

Locate a secure grounding connection as close to platinum series as possible.

Make sure the location is clean and provides a direct electrical connection to the frame 

of the vehicle. 

Connect one end of a short piece of the same gauge cable as the power cable to the grounding point. 

Run the one end of the cable to the grounding point.

Run the other end of the cable to the mounting location

Connect the ground cable to the screw terminal labeled as GND.

REM ( REMOTE CONNECTION )

Run a remote turn on cable from the head units remote sw 12V output.

Summary of Contents for OKUR A775.4

Page 1: ...nual Instalation Instructions Owners Manual Due to continuous improvement of the product the Specifications are subject to change without notice A775 4 A7125 4 A7300 2 A7750 1 A71100 1 A71500 1 A72000...

Page 2: ...8 5 16 Volts 20Hz 250Hz 100dB 250 6V 0 2V Variable 35Hz 250Hz Vairable 0 9dB Variable 10Hz 50Hz Variable 0 180 degree Yes Yes Yes 1 ohm for single unit 2 ohm for linked 1 2 OKUR 2 and 4channel class...

Page 3: ...the speaker outputs PHASE 0 180 degree It control phase from 0 180 degree OUTPUT MASTER INPUT SLAVE OUTPUT MASTER INPUT SLAVE connection makes OKUR digital amplifiers as daisy chain connection to 2 oh...

Page 4: ...cting multiple amplifer to the same RCA signal GND GROUND CONNECTION It is connected to the Negative or ground cables of the Vehicle Recommended wire is 4 gauge for A7300 2 A775 4 A7125 4 REM REMOTE C...

Page 5: ...mage to amplifier and audio system A775 4 A7125 4 A7300 2 A7750 1 A71100 1 and A71500 1 are designed to use minimum 4 gauge power and ground cables A72000 1 A72500 1 are designed to use minimum 0 gaug...

Page 6: ...als on each speaker Strip 3 8 of insulation from the end of each cable and twist the cables strands together tightly Make sure there are no stray strands that might touch other cables or terminals and...

Page 7: ...R CONNECTION DIAGRAM 2 8 2 ohms 8 2 ohms OKUR 4CHANNEL AMPLIFIERS SPEAKER CONNECTION DIAGRAM 1 8 2 ohms 8 2 ohms 8 2 ohms 8 2 ohms CAUTION A7300 2 A775 4 A7125 4 Amplifiers minimum impedance is 2 ohms...

Page 8: ...8 4 ohms OKUR 4CHANNEL AMPLIFIERS SPEAKER CONNECTION DIAGRAM 2 8 2 ohms 8 2 ohms OKUR 4CHANNEL AMPLIFIERS SPEAKER CONNECTION DIAGRAM 3 8 2 ohms 8 2 ohms 8 2 ohms 8 2 ohms 8 4 ohms...

Page 9: ...ter amplifier to the head unit and set its output master and input slave switch to output master position Step 2 Connect the master and slave amplifiers in daisy chain Rca jack as shown in the diagram...

Page 10: ...CAUTION A7750 1 A71100 1 A71500 1 A72000 1 A72500 1 Amplifiers Linked minimum impedance is 2 ohms Remote turn on 12V Ground BATTERY Ground MASTER AMPLIFIER SLAVE AMPLIFIER 8 2 ohms...

Page 11: ...edance for all Class D mono amplifiers is 1 ohm for single unit and 2 ohm for linked operation 3 If the OKUR amplifiers are shut down due to overheat Reset by turning off the remote input and alowing...

Page 12: ...This limited warranty does not extend to units that have been subjected to misuse abuse neglect or accident Products that in DB DRIVE s judgment shows evidence of having been altered modified abused o...