background image

DSP Functions

(20) 

Feature C

o

ntr

o

ller (LCD mat rix, 

si

ngle -kn

o

b, bezel m

o

unted)

 

a) V

o

lume: 

Range: 0 ~ -100dB, Step: 1dB 

b) High pa

ss

 Filter

:   

o

Frequency Select:

 31.5Hz ~ 125Hz, Step: 1 / 6 Oct.   

Sl

o

pe:

 Flat/-12dB/-24dB 

A. L

o

w pa

ss

 Filter

:   

a) Frequency Range:

 31.5Hz ~125Hz, Step: 1 / 6 Oct. 

b) Sl

o

pe:

 Flat/-12dB/-24dB 

c) Variable Pha

s

e:   

Range: 0° ~ -180°, Step: -5° 

d) High Pa

ss

 Delay:   

Delay Time Range: 0ms ~ 10ms, Step

0.1ms 

 

B. R

oo

m Gain C

o

mp

 (Deleted with room auto-EQ):   

a)

Enable/Disable 

b)

FREQ: 25/31/40 Hz 

c)

Slope:-6/-12dB/Oct. 

C. Subw

oo

fer tune m

o

de:

 Sealed/16Hz/20Hz/25Hz 

D. Three-band Parametric EQ   

a)

Frequency Range: 31.5Hz ~125Hz, Step: 1/12 OCT 

b)

Level Range: +3dB ~-12dB, Step: 1dB 

c)

Q Range: 2.0 / 2.4 / 2.9 / 3.6 / 4.8 / 5.7 / 7.2 / 9.6 / 14.4 

E. Aut

o

 R

oo

m EQ (

o

p

tio

nal, incl. mic ch

o

ice, dedicated ADI Sharc™ DSP, advanced pr

o

gram-ready) 

o

3 posi

ti

on acquisi

ti

on. Each pos. calc. with 12 measurement, 5-band PEQ correc

ti

on 

F. Input S

o

urce:   

o

Analog or Digital audio source selec

ti

on 

Advanced C

o

ntr

o

l (f

o

r GUI via USB p

o

rt, PC 

o

r Mac)

a) R

oo

m aut

o

-EQ 

GUI gives post-correc

ti

on spectrum display, EQ variance/specs 

b) I/O level meter (0-99dB) 
c) Five-band Parametric EQ Se

tti

ng

s

 

o

EQ type

s

: Peaking, high shelving, low shelving, notch, HPF, LPF 

o

Frequency range

: 20Hz ~200Hz, Step: 1Hz 

o

Level range

: +12dB ~ -6dB, Step: 0.1dB 

Q range

: 0.4 ~11, Step: 0.1 

d) LIMITER 

o

Thre

s

h

o

ld

:    -12~0 dB, Step: 0.1dB 

o

A

tt

ack:

    0.1 ~100ms, Step: 0.1ms 

o

Relea

s

e:

 100~5000ms Step: 0.1ms  

          

Summary of Contents for SPA1200DSP

Page 1: ......

Page 2: ...2...

Page 3: ...erference received including interference that may cause undesired operation 2 FCC Radiation Exposure Statement Mobile device This equipment complies with FCC radiation exposure limits set forth for a...

Page 4: ...Back panel and input output I O de nition 5 SPA1200DSP and SPA2400DSP wiring 6 Feature control panel key 7 Amp system block diagram 8 Controlling your subwoofer via PC GUI 9 Feature menu display 12 iO...

Page 5: ...for firmware update by Dayton Audio release See Page 10 for more on the system flash update process 3 Analog input attenuation Affects analog balanced and unbalanced inputs only o Normal No attenuati...

Page 6: ...6 SPA1200DSP and SPA2400DSP wiring SPA1200DSP SPA2400DSP NOTE Do NOT bridge outputs Dual voice coil and dual driver loads only...

Page 7: ...y saving stand by state LIMIT LED Yellow Lit when Limiter is active FEATURE SETUP Single knob digital actuator with single double click enabled with rotary scrolling to navigate the amp s extensive fe...

Page 8: ...8 Amp system block diagram SPA2400DSP...

Page 9: ...Follow all safe practices and contact Dayton Audio if you require assistance Read Setting Read all the setting from amp Save Settings to File Save current settings to PC Load Settings from File Load...

Page 10: ...by cursor or direct input and or sliders Detailed tool tips shown a d above o 5 band digital PEQ a Band On Off Bypass or enable by clicking the colorized 1 5 buttons b Center Frequency CF Adjust Cente...

Page 11: ...rement of room acoustics requires moving your EQ mic through the room s listening and or viewing sweet spots typically affixed to a photo tri pod for best acoustical results Only three different posit...

Page 12: ...uble click brings you back to the main menu Subsequent rotation of the controller from the main menu navigates you through a series of setup menus Each of the Function frames at left correspond to the...

Page 13: ...13...

Page 14: ......

Page 15: ...t connected your iPhone to the amp the app will automatically enter demo mode The demo mode is just a demonstration of each function Optimally smooth operation is not functional in demo mode but each...

Page 16: ...turn on the amp The device will immediately enter the firmware upgrade mode When the device successfully enters this mode the Standby STB LED will begin blinking 3 Connect your PC s USB cable to the...

Page 17: ...ad the updated firmware file from your saved location and select which new version by clicking the above Load File button 6 When the firmware update is loaded the below panel and green progress bar wi...

Page 18: ...18 7 Press UPDATE and the firmware will begin installation 8 After installation is complete the panel shows...

Page 19: ...ss RUN or cycle power on your amp and the device will now run the new rmware version 10 To validate your rmware was successfully updated you can note a new operating system version number V X 0X on am...

Page 20: ...Hz Step 1 12 OCT b Level Range 3dB 12dB Step 1dB c Q Range 2 0 2 4 2 9 3 6 4 8 5 7 7 2 9 6 14 4 E Auto Room EQ optional incl mic choice dedicated ADI Sharc DSP advanced program ready o 3 position acqu...

Page 21: ...PA2400 x 2 1 THD N 80Hz 230VAC 1 THD N 80Hz 115VAC 1350W 1300 W Auto ON OFF Auto ON sensitivity Auto OFF time RCA Left 80Hz 3mV 15mins Time delay 2ms Power ampli er protection A Short circuit and unde...

Page 22: ...s holes in the cone or broken lead wires Warranty does not apply to misuse abuse neglect accident improper use etc Dayton Audio reserves the right to repair or replace the products with either a new o...