PROTEC
AC-400 USER MANUAL V2.20
Specifications:
Dimension
:
Package 700*630*1230mm; Unpacked machine 635*585*1075mm
Input power
:
AC220V±10
%
~50/60Hz
,
or AC110V±10
%
~60Hz
Compressor power
:
3/8HP
Average gas state refrigerant recovery speed (through charge/suction port)
:
0.25Kg/min.
Hand valves free.
Recovery rate: 99%, recovery to -0.5BAR.
Pressurization to speed up old oil discharge.
Vacuum pump capacity
:
60L/min.
TEKTINO individualized drier-filter capacity: 600ml
Accuracy of gas cylinder load cell
:
±10g
Accuracy of oil bottle load cell
:
±5g
Gas cylinder capacity
:
10KG Max.
New/old oil bottle capacity
:
330ml
System Max. Pressure
:
20bar
Charge speed
:
2Kg/Min(max.)
LCD display
:
105.5*67.2mm, 480RGB x 272 Dots ,TFT full color
High pressure gauge range
:
-1bar~3.5MPa
Low pressure gauge range
:
-1bar~3.5MPa
A/C database included, update through USB port.
Automatic service reminding. The equipment provides 1200 operations totally (each recovery or
vacuum counts for one operation) between regular maintenances. When 1200 operations have been
made the machine automatically reminds to call distributor for service.
Thermal printer
Optional: Refrigerant adding port for external gas cylinder. The recovery speed of liquid state refrigerant
through this port: 0.35KG/min.
Optional: Condenser and cooling fan.
Optional: Vacuum leak test.
Optional: Heater band
Optional: Large capacity vacuum pump 120L/mn.
Optional: HP leak test at 2.0MPa.
2/24