Alarm Configuration Enable or Save

 

 

  Highlight desired “ENABLE” option to arm selected alarms and save alarm 

configuration or “SAVE” option to save alarm configuration without arming alarms. 
Use UP and DN switches to toggle the setting.  

 

    A L A R M   C O N F I  G    
  E N A B L  E     >  S A V E <   

 
 

Push “SELECT” to continue. The alarm configuration settings are saved in non-volatile 
memory.  

  

 

Activate Alarm 

- Activate tuner alarm conditions saved in configuration by holding SELECT and 

PRESETS buttons both in for 5 seconds to enter ALARM CONFIG menu and selecting “ENABLE” 
using UP and DN switches to toggle the setting.  Pushing “SELECT” arms the alarms; tuner VFD 
alternates between “ALARM SET” message and normal VFD display for the station. 

Front panel of the 

tuner is locked whenever alarm is armed to prevent false alarm conditions.  

 

De-activate Alarm 

- To de-activate the configured alarm functions, hold SELECT and PRESET buttons 

both in for 5 seconds. Tuner VFD display returns to normal operation and front panel of the tuner is un-
locked. 
 

Alarm Notification and Reset

 - When any alarm is active, audible alarm will sound (modulated 

beeping, if Alarm Buzzer has been set to “ON”) and second line of VFD will scroll an alarm message 
indicating “ALARM” and the specific alarm that is active, for example “ALARM – RF CARRIER LOSS, 
PRESS SELECT TO CLEAR”. Pressing SELECT and PRESETS buttons will clear all alarms. 
 
If during an alarm active condition the alarm condition is corrected, the tuner will reset to its state before 
the alarm occurred and the audible alarm will cease. The tuner alarms as configured will remain active 
until de-activated by the user, as described above. 

 

M4.2R Ethernet Port Set-up 

 
The M4.2R adds includes DaySequerra’s

 

Remote Dashboard

 TM

 software, a proprietary PC-based 

application, and an Ethernet interface to provide remote control monitoring for both AM and FM HD 
Radio 

TM

 broadcasts as well as a robust alarm panel for HD Radio

TM

 signal and data attributes.   

 
Please email your M4.2R serial number and contact information to 

support@daysequerra

.com or 

register your unit on our website 

www.daysequerra.com

 to obtain the password for CD-ROM 

containing the 

Remote Dashboard

 TM

 software application, supporting firmware and User Guide that 

came with your M4.2R. Follow the instructions in the 

Remote Dashboard

 TM

 User Guide to change your 

M4.2R’s IP address and complete the software installation before connecting the PC and using your 
M4.2R for the first time.     
 
In the event that you encounter any difficulties with your DaySequerra 

Remote Dashboard

 TM

, please 

feel free to contact us at 856-719-9900.  Our office hours are from 9 to 5 ET, Monday through Friday.  
Or you can email your questions to: 

[email protected]

.

 

Summary of Contents for M4 Series

Page 1: ...M4 Tuner User Manual...

Page 2: ...ing field testing and careful refinement In the event that you encounter any technical or operational difficulties with this or any DaySequerra product please feel free to contact us at 856 719 9900 O...

Page 3: ...Monitor PLM including 6 dry contact alarm relay closures full time digital audio output Ethernet remote port and RBDS decoding Eliminated Standby at Turn on feature and improved brown out performance...

Page 4: ...as designed to be the industry benchmark in sensitivity 5 0dBf in FM and reliability and at the same time deliver the highest quality most accurate monitoring of existing analog and HD RadioTM AM and...

Page 5: ...D SPLIT MODE HD RadioTM level phase and time alignment monitor for analog diversity delay RBDS DECODING M4 2R only Program Service PS and Radio Text RT fields displayed on VFD PROGRAMMABLE STATUS ALA...

Page 6: ...connected from the M4 s IEC320 power entry module to an AC mains outlet with a functional earth ground connection The M4 has been set at the factory to operate at 120VAC unless otherwise specified on...

Page 7: ...next field The second menu field enables or disables Audio Muting Next press of SELECT saves the setting and exits the menu Blue LED illuminates only when mode is active Default is AUTO mode with sta...

Page 8: ...recall in positions A1 through A20 and F1 through F20 respectively for AM and FM bands PRESETS Arrow LED illuminates when tuner is in PRESETS tuning mode UP and DN scroll through the preset stations...

Page 9: ...Station program type Song title Artist Album Genre Comment Subsequent momentary push of DATA DISPLAY switch turns DATA DISPLAY mode and DATA DISPLAY LED off The second line of VFD display scrolls if...

Page 10: ...l on recessed TRS jack Default set at the factory is 4dBm Sample VFD Displays HD RadioTM FM Multicast HD 2 channel selected F M 1 0 8 3 H D 2 S P O R T S HD RadioTM AM WATT AM tuned to preset position...

Page 11: ...DN switches to toggle the setting Push SELECT switch to increment the menu to the next alarm function A L L A L A R M S O N O F F S E T U P Alarm Output 1 RF Carrier Loss alarm based on analog RF sign...

Page 12: ...T to continue A U D I O L O S S S E T O F F If SET is selected submenu for Level threshold with LOW MED and HIGH options is displayed next LOW option sets audio loss threshold for approximately 60dB M...

Page 13: ...the next alarm function Alarm Output 4 RBDS Data Loss alarm based on data appearing in Radio Text field available in M4 2R model only Alarm Output 5 HD RadioTM PAD Loss alarm based on data appearing s...

Page 14: ...function to be alarmed and continue with alarm configuration menu select OFF to set this tuner alarm function to off Push SELECT to continue A L A R M O U T P U T 6 M C A V D L A Y O F F If MC AV or...

Page 15: ...is active for example ALARM RF CARRIER LOSS PRESS SELECT TO CLEAR Pressing SELECT and PRESETS buttons will clear all alarms If during an alarm active condition the alarm condition is corrected the tu...

Page 16: ...accordingly DaySequerra reserves the right to replace any product that has been discontinued from its product line with a new product of comparable value and function This warranty shall be void in t...

Reviews: