Days EQUALIZER SYSTEMS AM Series Installation And Operation Manual Download Page 2

 

 

 

 

 

 

 
 

Switch Harness and Hydraulic Lines 

 

 

The AM

 J

ack has been shipped with all necessary

 S

witchgear,

 H

arnesses and

 H

ydraulic

 L

ines. 

These items are specifically

 e

ngineered to operate your

 S

ystem and should not be altered in any 

m

anner. Modification of any

 f

actory supplied item may result in the denial of all warranty claims. 

 

Switchgear 

The Unit may

 have been provided with a key switch in the switchgear box (depending on the option 

ordered).

 If unit is not supplied with a key switch, the +12v battery lead must be fed through a power 

disconnect switch to fully isolate the system during travel or inactivity. Minimum disconnect switch rating 
must be Minimum 100 ampere DC. Switchgear is plugged into the system harness through a weather 
resistant connector (shown in Fig.1) 

 

 

 
 

Fig.1

-

 Weather Resistant Connector 

 

 

 

 

 
 

Battery Connections  
 

Pumps #’s 2142, 2390, 2532, 3126, 3170: 

Battery Lead (+12volts):

 Attach a

 # 4 gauge wire

 between the positive (+12V) terminal on the 

battery and the large post on the solenoid opposite the black motor wire on the solenoid. If circuit 
protection is required, Install an 80 amp (minimum) circuit breaker. 
 

               

Battery / Pump Ground (-12volts):

 Attach a

 # 4 gauge wire

 between the negative (-12v) terminal 

on the battery and the ground stud located directly in front of the motor. It is not acceptable to allow 
the Jack mounting bolts or the weld to be the sole grounding connection. 
 

              

Pump #’s 3040, 3041, 3200, 3201 and 3201KS see Fig. 2 

Attach a minimum

 # 6 gauge wire

 between the positive (+12V) terminal on the battery and the plus (

 +

 ) 

terminal on the contactor. Attach a minimum

 #6 Gauge wire

 between battery negative (

 -

 ) and the 

negative terminal on the contactor. Note: These units will not ground thru the mounting. The described 
ground/negative battery to contactor connection must be made.  

 

Fig. # 2: Pictured 
Pump #’s, 3040, 3041, 
3200, 3201 and 3201KS 
 

Attach battery negative 

(ground) to  

contactor here  

(6 gage min) 

 

12V 

Positive from Power Supply 

(6 gage min) 