![DAYLIFF SUNVERTER 4 Installation & Operating Manual Download Page 33](http://html2.mh-extra.com/html/dayliff/sunverter-4/sunverter-4_installation-and-operating-manual_5131103033.webp)
6
29
5.3 Fault Inquiry and Reset
The Sunverter records the fault codes of the latest 4 events. Searching this information
will help find the fault cause. Fault information is stored in the control parameters
Pr.20~Pr.23 refer to the panel operation instructions to view the fault codes and find
solutions.
When a fault occurs and the inverter needs reset to return to normal, press key to
reset or switch off power supply.
CAUTION
Be sure to check the cause of fault and eliminate it before
resetting. Continuous resetting of the inverter is harmful to
the controller.
CAUTION
Allow delay of 5 minutes before reset for overload and
overheat protection
5.4 Other Codes Description
Important Note
Code
Code Description
Explanation
Return to normal after resetting
User parameters initialization
Important parameter modification
All parameters initialization
Return to normal after resetting
Return to normal after resetting
Model Setting Error
Three-phase 220V, rate power 1,500W
Single-phase 220V, rate power 1,500W
Three-phase 380V, rate power 3,000W
Inverter Model
Set the dipswitch correclty, execute all parameters
initialization
Start Delay Time
Countdown of the restart: 30 seconds
STOP
Summary of Contents for SUNVERTER 4
Page 1: ...SUNVERTER 4 AC SOLAR PUMP CONTROLLER Installation Operating Manual...
Page 2: ......
Page 12: ...4 8 3 4 Wiring Diagram Fig 4 System Wiring Diagram...
Page 39: ......