![DAYLIFF SUNFRIDGE 55 Installation & Operating Manual Download Page 17](http://html1.mh-extra.com/html/dayliff/sunfridge-55/sunfridge-55_installation-and-operating-manual_3897192017.webp)
M a l f u n c t i o n o f
temperature sensor
LED display “Err 0”
unit not running
14
Over voltage or under
voltage
LED display “Err 1”
unit not running
Fan overcurrent
LED display “Err 2”
unit not running
M a l f u n c t i o n o f
c o m p r e s s o r s t a r t i n g
(unbalance of system
pressure)
LED display “Err 6”
unit not running
Check if there are hot foods in the freezer
an eliminate
Check if compressor vents are covered
and correct
Check fan is running correctly
Switch off the power for 30mins and
restart
L E D d i s p l a y “ E r r
3 , 5 , 7 ” u n i t n o t
running
LED display “Err 4”
u n i t n o t r u n n i n g,
fridge overload
Contact a local repair center
Compressor controller
malfunction
Replace compressor
Rotor is blocked
LED display “Err 8”
unit not running
Remove the cable of the T terminal of
compressor controller, short circuit of
terminals C and T of compressor
controller, once the compressor work well,
plug in the cable of T terminals
Power off the freezer, 30 min later, power
on the freezer again
Replace of it
M a l f u n c t i o n o f t h e
compressor
SUNFRIDGE 128/223
Check that power supply conforms to
product nameplate
Check battery voltage and correct as
necessary
Replace fan