8. TERMS OF WARRANTY

ii)   Standard Warranty

General Terms

If  equipment  failure  occurs  in  the  normal  course  of  service  having  been 
competently  installed  and  when  operating  within  its  specified  duty  limits 
warranty will be provided as follows:-

 

Up to 1 year - The item will be replaced or repaired at no charge.

  Over 1year, less than 2 years - The item will be replaced or repaired 

at a cost to the customer of 50% of the Davis & Shirtliff market price.

The warranty on equipment supplied or installed by others is conditional upon 
the  defective  unit 

being  promptly  returned  free  to  a  Davis  &  Shirtliff 

ofce

 and collected thereafter when repaired. No element of site repair is 

included in the warranty and any site attendance costs will be payable in full at 
standard  chargeout  rates.  Also  proof  of  purchase  including  the  purchase 
invoice must be provided for a warranty claim to be considered.

I)   General Liability 

•   In lieu of any warranty, condition or liability implied by law, the liability of 

Davis & Shirtliff (hereafter called the Company) in respect of any defect or 
failure  of  equipment  supplied 

is  limited  to  making  good  by

 

replacement  or  repair

 

(at  the  Company's  discretion)  defects  which 

under  proper  use  appear  therein  and  arise  solely  from  faulty  design, 
materials  or  workmanship  within  a  specified  period.  This  period 
commences 

immediately after the equipment has been delivered to 

the customer

 and at its termination all liability ceases. Also the warranty 

period will be assessed

 

on the basis of the date that the Company is 

informed of the failure.

Ÿ

This  warranty  applies  solely  to  equipment  supplied  and 

no  claim  for 

consequential damages,

 however arising, will be entertained. Also the 

warranty specifically excludes defects caused by fair wear and tear, the 
effects  of  careless  handling,  lack  of  maintenance,  faulty  installation, 
incompetence on the part of the equipment user, Acts of God or any other 
cause  beyond  the  Company's  reasonable  control.  Also,  any  repair  or 
attempt  at  repair  carried  out  by  any  other  party 

invalidates  all 

warranties.

17

Summary of Contents for DSTEAM120

Page 1: ...Steam Generator STEAM GENERATOR...

Page 2: ......

Page 3: ...10 4 1 Steam Room Design 7 6 TROUBLE SHOOTING 14 8 TERMS OF WARRANTY 17 Davis Shirtliff Ltd 2022 Contents herein are not warranted 5 OPERATION 12 7 MAINTENANCE 16 5 2 Setting Time Temperature 13 5 3...

Page 4: ...g a steam head and auto drain valve Provision for auto descaling is provided OPERATING CONDITIONS Water Pressure Min 0 25Bar Max 8Bar Water Quality Hardness less than 50ppm CaCo above which regular de...

Page 5: ...where both the electrical power and water supply can be isolated in an emergency WARNING The minimum water inlet pressure is 0 25 bar and a maximum of 8 bar working pressure should not exceed 5 bar W...

Page 6: ...led on level ground WARNING The Steam generator should not be in close proximity to hazardous substances WARNING The size of heater required to heat a particular size of steam room is dependent on typ...

Page 7: ...Insulation Material 7 Detect the water level Water Level Probe 8 Steam Outlet Steam Outlet 9 13 Operates if the pressure in the boiler exceeds 10 2bar 10 11 12 Pressure Relief Valve 0 To protect boile...

Page 8: ...lly when not steaming On Off On Off Light Light Temperature Display Time Display Push to operate lights Drain Drain Fan Mode Mode Enter 4 Dual function button used when steaming to set the time temper...

Page 9: ...Drain LED 13 Operation mode indicator red is for steam on demand mode and green for conventional timing Mode LED 14 Green indicates heating is on red indicates the required temperature Heating LED 15...

Page 10: ...W will heat up to 3 1m of air For dense materials such as stones and ceramics which conduct heat more 3 rapidly allow for up to 2kW per m of air Hot air rises so restricting the height to around 2 met...

Page 11: ...e included in the controller to set working times in regular intervals of 30minutes The steam generator should be installed in a dry well ventilated place in close proximity to the steam room It can b...

Page 12: ...fort it s h o u l d b e a t t h e farthest place from the seat STEAM GENERATOR Valve Water Level Probe Overheat Switch According to the location it may be necessary to attach an additional length of p...

Page 13: ...am room at approximately 1 2 to 1 5 meters high and away from the door respective Use a 4mm screw to fix it in place and connect to the wire from the controller 10 Temperature Sensor 4 Screw Installat...

Page 14: ...Fig 10 11 9kW Steam Generator Circuit Diagram 12 15kW Steam Generator Circuit Diagram Fig 11...

Page 15: ...the water inlet valve will turn off 3 After a few minutes of operation the generator will begin steaming for small steam generator 2 3 minutes and about 3 5 minutes for larger generators 4 Press the k...

Page 16: ...altering the settings of the JP1 pins on the circuit board Fan Enter Set Clean 5 2 Setting Time and Temperature 0 The steam generator default settings are 40 C temp and 1 hour of operation which can b...

Page 17: ...with clean water when the cycle is complete the drain LED will go off 2 Ensure there is sufficient descaling solution in the container to completely fill the boiler when liquid level reaches set poin...

Page 18: ...here is no steam being produced 1 Replace main circuit board 2 Replace relay circuit board 3 Replace heating elements 1 Main Circuit Board Faulty 2 Relay Circuit Board Faulty 3 Heating Elements Faulty...

Page 19: ...sulting in leaks from around the elements The extent of the problem will vary according to the degree of hardness in the local water supply It is recommended to use water softener NOTE All commercial...

Page 20: ...ranty condition or liability implied by law the liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by replace...