Problem
Possible Cause
Solution
The pump
does not
run
The fuses are blown
Replace the blown fuses. If
the replacements blow too,
the electric installation and
the submersible drop cable
should be checked
The ELCB or the voltage-
operated ELCB has tripped
out
Re-set the circuit breaker
The motor overload has
tripped out
Reset the motor starter
overload. If it trips again,
check the voltage and if
normal call service technician
Motor starter/contactor
defective
Repair the motor starter/
contactor
The control circuit has been
interrupted or is defective
Check the electric installation
No electricity supply
Contact the power supply
provider
The dry running protection
has cut out the pump due to
low water level
Check the water level. If it is in
order check the water level
electrodes/level switch
The pumps submersible drop
cable is defective
Repair/replace the pump/
cable
11
8. TROUBLE SHOOTING GUIDE
The protection relay has
tripped due to power
inconsistencies
Contact the power supply
provider