SV:

 Voltage of PV Panels 

I:

 Working Current 

BV:

 Voltage of Batteries 

C:

 Charging Current 

T:

 Run Duration 

P:

 Power 

N:

 Motor Speed 

30:

 Time (S) 

Under  default  setting,  press"VAP/UP"button,  LCD  shows  the  voltage, 

current, power. After 40seconds, back to default. 

Summary of Contents for DP SOLAR

Page 1: ...DP SOLAR Solar Pool Pumps Installation Operating Manual ...

Page 2: ...PUMP SPECIFICATIONS 1 1 2 INSTALLATION 3 MAINTENANCE 3 4 TROUBLE SHOOTING 4 5 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted WARRANTY 5 6 ...

Page 3: ... operation Integrated MPPT Maximum Power Point Tracking Graph 1 2 Average Daily Irradiation Values Kwhr m Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1 2 3 4 5 6 5 6 7 6 3 6 5 6 0 5 8 5 6 5 7 5 6 6 5 5 8 5 1 5 3 Graph 2 Daily Output 6 00 7 00 8 00 9 00 10 00 11 00 12 00 13 00 14 00 15 00 16 00 17 00 18 00 2 12 13 13 13 12 10 2 0 0 7 10 7 Time hrs 1 1 PUMP SPECIFICATIONS PUMP HEAD m FLOW RATE m...

Page 4: ...ion of the estimated hourly irradiation as shown in Graph 2 NOTE Output estimations are strictly indicative More accurate projections are available using manufacturers data when the exact site location and installation arrangement is defined This information will be provided with all offers OPERATING CONDITIONS Pumped Liquid Thin clean non aggressive liquids not containing fibers or particles 0 Ma...

Page 5: ...protect immediately The system will try to restart after 15minutes Low Power Protection Operating current 0 6A Input Voltage 25VDC or 100VDC It will be protected and stop controller will try to restart after 20minutes 2 WARNINGS SYMBOLS WARNING Wiring of the system must be correct P P B B are the terminals of power input misconnection will cause the damage of the controller when power on WARNING T...

Page 6: ...ot touch or inspect the components or signal of the printed circuit board WARNING Do not touch the radiator or fever parts to prevent scalding 3 1 Wiring Diagram 3 2 Technical Program As shown below Turn the switch to BATTERY 1 2 3 ...

Page 7: ...ct with the anode of battery for 48V pumps only Connect with the cathode of battery for 48V pumps only Connect with the motor wire brown Connect with the motor wire green Connect with the motor wire black 4 OPERATION 4 1 Board Structure Includes a LCD Display Screen five Buttons and a Switch Display Screen Buttons Switch ...

Page 8: ... DESIGNATION DESCRIPTION 1 Under Default Display Press VAP UP to enter Parameters Display 2 Under Default Display Press SET DOWN to enter Setting Menu 3 Under Default Dispaly Press to Start Manually 4 Under Default Display Press to Stop Manually 5 Under Setting Menu Press or to choose the needed parameter 6 Under Setting Menu Press SURE to enter Parameter Modification 7 Under Parameter Modificatio...

Page 9: ...urrent Protection Active V Overvoltage Protection Active 100 Motor Speed 100 15 Protection Reset Interval 15 minutes V 20 85V The range of input voltage 199 Startup times 0 03 20 Run Duration H M S Default display on running state LCD shows the operation condition the parameter of previous settings SV 27 V I 0 A BV 0 V C 0 A T 0 h P 0 W N 0 rpm 30 5 ...

Page 10: ...els I Working Current BV Voltage of Batteries C Charging Current T Run Duration P Power N Motor Speed 30 Time S Under default setting press VAP UP button LCD shows the voltage current power After 40seconds back to default ...

Page 11: ... condition or liability implied by law the liability of Dayliff hereafter called the Distributor in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair at the Distributor s discretion defects which under proper use appear therein and arise solely from faulty design materials or workmanship within a specified period This period commences immedia...

Page 12: ...INS300D 07 20 ...