background image

2

*Acoustic Set with AMF noise level: 70dBA@7m

NOTE: 

Given outputs are sea level ratings. Sets should be rated at 1% for every 100m 

0

0

higher than 100m above sea level, and 2% for every 5 C temperature above 20 C.

Welding Data

Specications

Electrical Data

Alternator:

 

Brushless, self exciting, 2 pole  

   Pole Output: 

50Hz, 240V single phase

Voltage Regulator:

 

AVR

                          Power Factor: 

1ph - 1,3ph - 0.8

Direct Current

DG-D

 -12V/6A

                 Speed:

 

3000rpm

                          

DGW-D

 -12V/8.3A  

Dimensions & Weights

Welding Performance

No Load 

Voltage

(V)

Operation 

Voltage

(V)

Operating

Current (A)

Welding Rod Currents (A)

2.5mmØ 3.2mmØ

4mmØ

Max. Arching

Current (A)

Model

1x240

Electric

418

7.7

6

12.5

4.6

4.2

LA186

DGW200D

65

28-35

50-120

50-100

100-160

DGW200D

160-180

180

Model

(mm)

W

(mm)

H

(mm)

Weight 

(kg)

740

475

590

125

DGW200D

L

W

H

Fuel

Tank

Capacity

(litres)

Model

Rated
(KVA)

Max

(KVA)

Start

Type

Output

Model

Engine

Capacity

(cc)

Max

Power 

(HP)

Opera-

ting

Period

(Hrs)

LA186FAFG 

418

8.5

4

12.5

5.0

1x240

4.5

DG6000D

Voltage

(V)

3x415

Electric

954

20

12

50

13.7

12.5

LA290

1x240

Electric

954

20

12

50

11

10

LA290

DG12000DSM*

DG12000DST*

1x240

1x240

1x240

3x415

Recoil/Electric

Electric

Recoil/Electric

418

499

499

499

8.5

10

10

10

5

16

12.5

25

12.5

5.0

6.5

6.5

8.1

4.5

6.0

6.0

7.5

DG6000DS*

LA186FAFG 

LA192F

LA192FAG

LA192F

Recoil

LA178FG 

306

5.5

18

12.5

3.0

1x240

2.7

DG3600D

DG8000D

5

8

8

Recoil/Electric

Recoil/Electric

DG8000DSM

DG8000DT

740

475

590

95

1150       670

940

295

900   

740  

960  

520

475

560

700

600

710

150

120

164

680

455

545

80

DG6000D

DG12000DSM

DG12000DST

DG6000DS

DG3600D

DG8000D/
DG8000DT

DG8000DS

Summary of Contents for DG3600D

Page 1: ...Installation Operating Manual DG Portable Diesel Generators DG 12000DS DG 6000DS DG8000DSM DG3600D DG6000D DG8000D DG8000DT DGW200D...

Page 2: ......

Page 3: ...CATIONS 1 1 2 SAFETY WARNINGS 3 CONTROLS 3 3 ELETRICAL CONNECTIONS 4 3 GENERATOR OPERATION 5 4 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted ROUTINE MAINTENANCE 6 4 TROUBLE SHOOTING...

Page 4: ...les fully automatic power failure operation not open sets l Strong tubular frame for protection and ease of handling open sets l Acoustic models further strengthened canopy on castors limits noise to...

Page 5: ...20 50 100 100 160 DGW200D 160 180 180 Model L mm W mm H mm Weight kg 740 475 590 125 DGW200D L W H Fuel Tank Capacity litres Model Rated KVA Max KVA Start Type Output Model Engine Capacity cc Max Powe...

Page 6: ...enerator damage will occur Ensure a competent trained person is used in case of overhaul 3 CONTROLS All generators are fitted with the following 2no 3 pin AC outlets ve and ve DC connections Engine on...

Page 7: ...roperly earthed Consult a qualified electrician if in doubt 5 GENERATOR OPERATION CHECK ENGINE OIL Operating without oil will cause severe engine damage and invalidate the warranty To start ensure ign...

Page 8: ...tage Excessive electrical load Engine does not start Clean carburettor Carburettor is blocked Clean and adjust plug Spark plug is wet dirty Clean air cleaner Air cleaner dirty Reduce oil to suitable l...

Page 9: ...condition or liability implied by law the liability of Dayliff hereafter called the Distributor in respect of any defect or failure of equipment supplied is limited to making good by replacement or re...

Page 10: ......

Page 11: ......

Page 12: ...INS182G 03 20...

Reviews: