DAYLIFF DG 950P Installation & Operating Manual Download Page 4

1

1.  GENERATOR SPECIFICATIONS

Thank you for choosing Dayliff DG generator. It has been manufactured to 
the highest standards and if operated correctly should give many years of 
efficient and trouble free service. Careful reading of this instruction manual 
is therefore extremely important and if you have any queries please refer 
them to your retailer.

The Dayliff Range of portable petrol generators are dependable, quality products 
specially designed for mains standby and remote site power supply applications. 
Particular features include:

Reliable and economical air cooled OHV petrol engines equipped with 

large size exhausts and  air cleaners for low noise operation

High efficiency square core alternators providing increased power output 

and enabling operation of sensitive electronic equipment

  AC auxilliary current and DC welding current can be used simultaneously 

(DGW)

DC output for battery charging
Strong tubular frame for protection and ease of handling(not DG950P and 

DG11000PS) 

Integrated  control panel  with voltmeter for operational convenience
Fuseless type over current protection
Oil alert system to stop engine in the event of low oil level(not DG950P) 
High capacity fuel tank for extended operation (not DG950P) 

Dayliff generators are of compact design and their advanced features make them 
suitable for all small scale power supply applications.

l

l

l

l
l

l
l
l
l

DG 11000PS

DG 950P

DG 5000P

DG 3500PX

DGW

Summary of Contents for DG 950P

Page 1: ...DG Portable Petrol Generators Installation Operating Manual DG 11000PS DG 950P DG 5000P DG 3500PX DGW...

Page 2: ......

Page 3: ...ATIONS 1 1 2 CONTROLS 3 ELECTRICAL CONNECTIONS 3 3 GENERATOR OPERATION 4 4 ROUTINE MAINTENANCE 5 4 INDEX Davis Shirtliff Ltd 2015 Contents herein are not warranted SAFETY WARNINGS 6 5 TROUBLE SHOOTING...

Page 4: ...ge size exhausts and air cleaners for low noise operation High efficiency square core alternators providing increased power output and enabling operation of sensitive electronic equipment AC auxilliar...

Page 5: ...nda GX160 4T 2 15 Electric LT390 4T 389 13 5 25 4 5 4 Honda GX390 4T Electric 389 13 5 25 5 5 5 Electric LT620 4T 2 Cylinder 614 20 3 25 9 5 8 5 LT200 4T LT210 4T 196 208 6 5 7 6 6 Recoil Recoil 2 5 3...

Page 6: ...the generator after disconnecting load Starting and stopping under load will damage the generator and powered accessories 3 ELECTRICAL CONECTIONS output must only be used briefly or generator damage...

Page 7: ...ing away accumulated dust and soaking in kerosene SPARK PLUG A correctly set spark plug in good condition is essential for efficient engine operation Check the plug every 3 months or after 50 hours op...

Page 8: ...Manual Ensure a competent trained person is used in case of overhaul Do not use generator on a slope Fuel spillage may occur and cause a fire Do not connect generators together Generator damage will o...

Page 9: ...tage Excessive electrical load Engine does not start Clean carburettor Carburettor is blocked Clean and adjust plug Spark plug is wet dirty Clean air cleaner Air cleaner dirty Reduce oil to suitable l...

Page 10: ...ndling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyond the Company s reasonable control Also any repair or attempt at repai...

Page 11: ......

Page 12: ...INS302F 06 15...

Reviews: