Starline Track Busbar – Scalable and Secure Power
for your Data Centre
System-No.
Ampere
Volt
Neutral
Isolated Ground
Dimensions
GM100
100
415
100%
No
106mm x 66mm
GM100G
100
415
100%
Yes
106mm x 66mm
GM100NG
100
415
200%
Yes
106mm x 66mm
GM225
225
415
100%
No
106mm x 66mm
GM225G
225
415
100%
Yes
106mm x 66mm
GM400/GM400G
400
415
100%
No/Yes
128mm x 145mm
GM400N/GM400NG
400
415
150%
No/Yes
128mm x 145mm
Versions and Options
5
2
Daxten
|
Starline
Track Busbar
Currently in mission critical, R & D and testing environments any short interruption or malfunction of
the power supply can have catastrophic effect on IT operations, company data and critical transactions. It is,
therefore, necessary to ensure busbar systems are dependable while offering the flexibility to make changes
when needed. Additionally, space restrictions and rack
density are becoming more important when planning
for the future. R&D as well as live data centres often
need to be reconfigured to real world scenarios or to
update hardware. Starline Track Busbar provides solid
and maintenance free connections while allowing for
speedy installation and more flexibility than traditional
cable whips and panel boards (PDUs).
Easy Installation and reconfiguration
Starline continuous access busbar allows for power plug-ins to be placed where they are required, not
at predefined locations. Power plug-ins are configured to customer requirements with 16A, 32A or 63A
single and/or three phase connectors. Available with 100, 225 or 400 Amps and up to 415 volts, Starline can
support any size of data centre. The connections between the tracks consist of a patent protected spring
pressure connection which is screw and bolt free, preventing loose connections or flaking. The same con-
nections are used to connect the power plug-ins to the busbar ensuring a secure and solid connection at all
times. The entire busbar system is easy to assemble and dismantle meaning that tracks can be inexpensively
installed, moved and reused regardless if it has been installed overhead or under the raised floor.
The plug-ins are designed to allow for individual requirements. Current monitoring, which can be
accessed via RS232, IP or Modbus, can be included per rack or per busbar run. The number of and type of
connectors is determined by your own needs. For example, a 16A single phase connector can be situated
next to a 32A three phase connector in the same plug-in. Even drop cords and hard wire options are available.
If redundancy is required, then a second parallel busbar is added. Starline is UL857 and UL94-V0 rated,
fulfils the EN 60439-1(-2) and IEC 60439-1(-2): 2000 standard and is ISO 9001-2000 compliant.