9. DAMAGE CODES  

When the water heater shows one of the codes from the following, this means there is trouble at 
the water heater. Water heater will be shut automatically. At this situation please shut your heater 
from the main power and do not use it then call the authorized service.        
 

 

 
 
 
 

IMPORTANT WARNINGS 
 

 

1.  Before operate the water heater, first electric wiring connections must be controlled.  
2.  Before first start up of the heater, provide passing water inside de the heater by opening hot 

water tap.   

3.  Do not install your heater where there is possibility for freezing and do not operate your 

heater in case of water freezing.  

4.  Connection of wires to the heater will be done by authorized services.  
5.  Electric wiring inside the house must be convenient according to water heater power and it 

is the responsibility of the consumer. Notice that the materials which are used in electric 
wiring connection must be suitable for standards.  

6.  Set up the temperature in suitable position for prevent from scalding.     
7.  Water Heater must be connected with suitable earth. Otherwise it is not allowed for the 

installation.    

8.  Do not use the water heater with watery and wet hands.  
9.  The installation of the heater must be done by authorized person.  
10. Children and people who have physically or mentally handicapped cannot be used this 

water heater without person who is responsibility from them. 

 
 
 

 

 

 

 

 

Summary of Contents for UKDAX-18GT

Page 1: ......

Page 2: ...matlara uyunuz Yetkisiz olarak montaj veya bak m yap lmas halinde cihaz garanti kapsam ndan kacakt r Buna ek olarak r nde meydana gelebilecek bir bozukluk veya kazadan firmam z sorumlu olmayacakt r L...

Page 3: ...e Paneli 5 Ak Sens r 6 Is Elementi 7 Is Sens r 8 85 Manuel S cakl k Ayarlay c 9 Kapak 10 Elektriksel Eleman 11 Alt Kutu 12 Elektrik Kontrol Mod l 13 Kablo Ba lant Kutusu 14 Devre A c Kesici 15 SCR Pan...

Page 4: ...3 ELEKTR KSEL EMAT K D AGRAM...

Page 5: ...80 Ak m A 27 Kablo ap mm2 4x4 mm2 Mesafeye g re uygun kesitte Min Debi lt dk 2 5 Max Debi lt dk 23 C 11 Max Su S cakl k C 55 Min Su S cakl C 30 E ektrik koruma IPX4 Max Su Bas nc Bar 6 Min Su Bas nc B...

Page 6: ...z n elektrik tesisat mutlaka yasal y netmeliklere uygun olarak YETK L ELEKTR K YE yapt r lmal d r Cihaz mutlaka dik olarak monte edilmelidir Cihaz ilk kullan mdan nce suyu a n sonra elektri i a n Ciha...

Page 7: ...n boyutlara g re uygun y kseklik se iniz ofben i in montaj konumunu ayarlay n Ayarlad n z konumda 2 adet delik a n 2 ofbenin alt arkas na montaj kapa n ba lay n Kablolar elektrik bloklar na ba lay n z...

Page 8: ...yerle tiriniz Duvar deste ine vidalay n z ve ofbeni duvar deste inin zerine s k ca monte ediniz 4 B noktas na viday monte edin Kapa ofbenin alt na tekrar tak n ve vidalay n 5 3 Su Tesisat Ba lant s Ci...

Page 9: ...aat y n tersi evrilir ise s cakl k azal r 7 C HAZIN ALI TIRILMASI Cihaz n ilk al t r lmas n mutlaka yetkili servisimize yapt r n z T m ba lant lar n z kontrol ettikten sonra S cak su muslu unuzu a n E...

Page 10: ...aber veriniz D k S cakl k 1 Ayarlanan s cakl k ok d k 1 S cakl Y kseltin veya suyu azalt n Y ksek S cakl k 2 Ayarlanan S cakl k ok Y ksek 2 S cakl D r n LED G stergesinde G r nt Yok 1 G Kapal 1 G c A...

Page 11: ...n donmas halinde cihaz n z al t rmay n z 4 Kablolar n cihaza ba lant s yetkili servislerimiz taraf ndan yap lacakt r 5 Bina i i elektrik tesisat cihaz g c ne uygun olarak haz rlanmal d r ve t keticini...

Page 12: ...n case of an unauthorized mounting and maintenance the device will be void from warranty cover In addition to that our company will not be responsible from failure or an accident that may occur in the...

Page 13: ...Pannel 5 Flow Sensor 6 Heating Element 7 Heating Sensor 8 85 Degree Mannuel Temperature Setter 9 Cover 10 Electrical Element 11 Low Cover 12 Electric Control Module 13 Cable Connection Box 14 Contacto...

Page 14: ...3 ELECTRICAL SCHEMATIC DIAGRAM...

Page 15: ...mpearture C 55 Min Water Temperature C 30 Electrical Protection IPX4 Max Water Pressure Bar 6 Min Water Pressure Bar 0 5 Water Connection Diameter Diameter mm 452 x 260 x 115 Breaker A 3 x 32 5 INSTAL...

Page 16: ...bility Connections must not be tighten so much for not to give damage If your water pressure is over 4 bar definitely pressure reduce valve must be installed to the heater inlet Use water flexes which...

Page 17: ...Place the plastic screw into the nut Screw to wall bracket and install the heater on the wall bracket tightly 4 Install the screw into B point Fix the cover under the heater again and screw it 5 3 Co...

Page 18: ...re will increase If it is turned as anticlockwise temperature will decrease 7 Operation of the Heater Definitely make start up of your heater to our authorized service After control all connections Op...

Page 19: ...Authorised service Low Temperature 1 Setting temperature is too low 1 Increase the temperature or less the water Higher Temperature 2 Setting Temperature is too high 2 Decrease the temperature Power L...

Page 20: ...r heater in case of water freezing 4 Connection of wires to the heater will be done by authorized services 5 Electric wiring inside the house must be convenient according to water heater power and it...

Reviews: