19
When heating system increases over 3 bar, water disposal starts from safety
valve.
For Ukdax-xxHBT ve Ukdax-xxHBM models , 50 K NTC boiler sensor must be
installed.
When boiler pressure increases over 8 bar, drainage starts from safety valve. (
For
Ukdax-xxEBM ve Ukdax-xxEBT
)Boiler max operating pressure is 6 bar. If
you suspect that system pressure is over 6 bar, install pressure reducer to inlet
of device or flat entrence
Device installation place must be far way from blockers, obstruction parts
and bulges during repairing and maintenance. There must be sufficient
space around the device for maintenance and repair.
Electric connection of the device must be made with suitable cable, fuse
and residual current device and grounding absolutely must be made.
Installation wall of the device must be as durable as carrying the weight of
the device.