The electrical installation must be carried out by a qualified
electrician using suitable diameter cable determined according
to the boiler capacity and cable length. The MCB and RCD
with appropriate characteristics and amperage which can cut
the boiler electricity completely should be located separately
and be close to the device. If there is no earthing installation in
the structure where the boiler is installed, the grounding line for
the boiler should be installed by a qualified electrician. The
Isolator switch
must be located near the boiler, and after the
Isolator switch
there must be enough cable to connect to the
boiler. The connection of the cables to the boiler must be done
by a qualified installer. Cable diameters calculated according to
boiler capacity and cable lengths, and MCB and RCD
amperage values can be seen in the table below.
Model
Pow
er
(kW)
Phase &
Voltage
(V)
Current
(A)
Fuse &
Residual
Current Device
(A)
Cable
Section
(mm)
UKDAX-10EBT
10
3~400
3*15,2
3*20
5*2,5
UKDAX-12EBT
12
3~400
3*18,2
3*20
5*2,5
UKDAX-16EBT
16
3~400
3*24,3
3*25
5*4
UKDAX-18EBT
18
3~400
3*27,3
3*32
5*4
UKDAX-20EBT
20
3~400
3*30,4
3*40
5*6
UKDAX-24EBT
24
3~400
3*36,4
3*50
5*6
UKDAX-6EBM
6
1~220
27,3
32
3*4
UKDAX-10EBM
10
1~220
45,6
50
3*6
UKDAX-12EBM
12
1~220
54,6
63
3*10
UKDAX-16EBM
16
1~220
72,8
80
3*16
UKDAX-18EBM
18
1~220
81,9
100
3*16