00-05-4268

Using the Tester

Standard 3 wire outlet

• 
• 

• 

Always test on a known good outlet before use.
Plug the tester into the outlet, check the indicator lights 

  and refer to the following table for the current state of 
  the outlet.

If incorrect wiring is indicated, do not use outlet. 

  Consult electrician.

Indicator

Fault

Open ground

Open neutral

Open hot

Hot/ground 
Reverse
Hot/neutral 
Reverse
Correct

Reason for Wiring Fault

Ground contact not connected

Neutral contact not connected

Hot contact not connected

Hot and ground contacts 
reversed

Receptacle is wired correctly

Hot and neutral contacts 
reversed

Specifications

• 

AC Voltage Range: 110~125V

• 

Overload voltage: CAT II 125V

• 

Humidity: <80% relative humidity

  

• 

Operating Temperature: 32F To 104F(0°C

 

to 40°C)

• 

Storage Temperature: 14F to 122F(-10°C

 

to 50°C)

• 

Altitude: ~6500 ft. (2000 m); indoor use only

• 

Dimension: 3.15 x 1.65 x 1.26

 

in. (80x42x32mm)

• 

Weight: Approx. 1.6oz (45g)