Dawson Tools DDM453 User Manual Download Page 7

11

6

9

Duty Cycle:<99

%

.2 

11. Non-Contact Voltage Detector:

NCV

 

7.

Specifications

DC Voltage Measurement

Range

Resolution

Accuracy

600mV

0.1mV

±(

0.5% of r2 digits)

6V
60V
600V

0.001V
0.01V
0.1V

 

Input impedance: 10MΩ

 

Max. input voltage: 600V rms

 
 

 

12

/

DDM453

/

DDM453

1.

Turn rotary switch to the Hz/% position.

2.

Press Hz/% to select duty cycle.

3.

Connect leads across circuit.

4.

Read measured duty cycle on the display.

1.

In any mode, hold the NCV button down.

2.

Move the top of the meter toward voltage source

3.

If AC voltage is present, NCV indicator flashes/buzzer beeps.

 

Safety Rating:

 CAT III 600V

 

Operating Altitude:

 2000m

 

Relative Humidity:

 75% max operating 

 

Operating Temperature:

 0°C~40°C/32°F~104°F (<80% RH)

 

Storage Temperature:

 -10°C~60°C/14°F~140°F (<70% RH)

• 

Accuracy Temperature:

 -18°C~28°C/64°F~82°F (<80% RH)

 

Temperature Coefficient: 

0.1x(specified accuracy)/°C (<18°C or >28°C)

 

Sampling Frequency:

 approx. 3 times/sec.

 

Fuse Protection:

 µA/mA input: FF 600mA H 600V  

                            10A input: FF 10A H 600V

 LCD Display:

 

 

 Supply: 

9V battery

 

150mm

×

74mm

×

48mm / 6.3"

×

2.9"

×

1.9"

 

Weight:

 

 

Safety Standards:

 IEC61010-1

 

Pollution

 

Degree:

 2

 

Accuracy:

 

±(

of

 

r # of least significant digits

)

6000 count display (5999 max reading)

Power
Dimensions

8.9oz/250g

 

7.

ELECTRICAL SPECIFICATIONS

/

DDM45

3

Summary of Contents for DDM453

Page 1: ...and we strive for 100 satisfaction we would appreciate your feedback on the product Our professional support team is always ready to answer your enquiries and provide assistance Please contact our cus...

Page 2: ...This instrument from Dawson Tools Inc will be free from defects in workmanship and material for three years from the date of original purchase This warranty does not cover defects resulting from damag...

Page 3: ...k current measurements between 600mA 10A only 9 Common Jack all measurements release the hold Hold to turn With the rotary switch in the Hz position the default mode is frequency Press the Hz button t...

Page 4: ...e Mode Temperature in Celsius Temperature in Fahrenheit Resistance Frequency Capacitance DC AC Current DC AC Voltage 6 5 1 DC Voltage 600V 1 4 5 6 7 8 9 2 3 1 10 11 12 13 6 DDM453 1 Turn rotary switch...

Page 5: ...he display 1 Turn rotary switch to mA position 2 Press FUNC to select DC or AC current 3 Connect leads in series to circuit 4 Read current measurement on the display 1 Turn rotary switch to mA positio...

Page 6: ...to switch to diode mode 3 Connect INPUT lead to anode and COM lead to cathode 4 Read measured forward biased voltage drop 7 Capacitance 60mF 6 DDM453 1 Turn rotary switch to the capacitance position 2...

Page 7: ...e is present NCV indicator flashes buzzer beeps Safety Rating CAT III 600V Operating Altitude 2000m Relative Humidity 75 max operating Operating Temperature 0 C 40 C 32 F 104 F 80 RH Storage Temperatu...

Page 8: ...ing 8 digits AC Measurement Current Range Resolution Accuracy 600 A 0 1 A 1 2 of reading 5 digits 6000 A 60mA 600mA 1 A 0 01mA 0 1mA Overload protection A mA input Fuse FF 600mA H 600V 10A input Fuse...

Page 9: ...reading 5 digits Max input voltage 600V rms Frequency AC voltage Range Resolution Accuracy 99 99Hz 0 01Hz 1 5 of reading 5 digits 999 9Hz 10kHz 0 1Hz 0 01kHz Reference only Signal input range 0 2V AC...

Page 10: ...r 3 Replace blow fuse s with new fuses of the same electrical ratings see specifications 10 REPLACING THE BATTERY To replace the 1 Turn off power to the meter 2 Remove test leads from input jacks 3 Lo...