M877 LSI Aircraft Time Management System

CLOCK OPERTION

Normal Operation

The SEL button selects what is to be displayed in the
four digit window and the CTL button controls what is
being  displayed.  Pressing  select  sequentially  selects 
GMT, Local Time, Flight Time, Elapsed Time and back 
to GMT. The CTL button starts and resets Elapsed Time 
when  momentarily  pushed.  Normal  operation  of  the 
877 cannot accidentally reset time.

Setting GMT

Select GMT for display in the four digit window with the
SEL button. Simultaneously press both the select and
control buttons to enter the set mode. The tens of hours
digit will start flashing. The control button has full con-
trol of the flashing digit and each button push incre-
ments the digit. Once the tens of hour is set, the select
button selects the next digit to be set. After the last digit
has been selected and set with the control button, a
final push of the select button exits the mode. The light-
ed annunciator will resume its normal flashing, indict-
ing the GMT clock is running.

Setting LT

Select  Local  Time,  LT,  using  the  SEL  button.
Simultaneously push the SEL and CTL buttons to enter
set mode.  The tens of hours digit will start flashing. The
set operation is the same as for GMT, except that min-
utes are already synchronized with the GMT clock and
cannot be set in Local Time. The minutes are already 
synchronized with GMT, but can be changed in 15 min-
ute increments for special time zones.

Control/Select Disable

When there is no aircraft power applied in the clock
CTL and SEL buttons are disabled.

Setting Flight Time Alarm

When Flight Time, FT, is displayed enter the set mode
by  pressing  both  buttons  simultaneously.  The  alarm
time is entered identically to GMT setting. When the
Flight  Time  equals  the  alarm  the  display  will  flash
and the alarm output activated. If FT was not being dis-
played at the time the alarm becomes active, the clock
automatically selects FT for display. Pressing either the
SEL or CTL button turns off the alarm and zeroes the
alarm  time.  Flight Time  is  unchanged  and  continues
counting.

Flight Time Reset

FT must be displayed when resetting. Hold CTL down
for 3 seconds, or until 99:59 Or 99:99 appears on the
display. The digits that appear depends on how the clock
is  programmed.  In  hour  and  minutes,  or  in  hours,
tenths and hundredths. Flight Time will be zeroed upon
release of the CTL button.

Elapsed Time Count Up

Select ET for display. Pressing the CTL button will start
ET counting. Elapsed Time counts up to 59 minutes, 59
seconds,  and  then  switches  to  hours  and  minutes.  It
continues  counting  up  to  99  hours  and  59  minutes.
Pressing the CTL button again resets ET to zero.

Elapsed Time Count Down

Select ET for display and enter set mode by pressing both
buttons. The countdown timer can now be set. Entering
the time is identical to GMT time setting. When the time
is entered and the last digit is no longer flashing the clock
is ready to start the countdown.  Momentarily pressing the
CTL button starts the countdown. When count reach-
es zero the displays flash and the external alarm is acti-
vated.  Pressing  either  SEL  or  CTL  will  deactivate  the
alarm. ET continues counting up.

Test Mode

Hold the SEL button down for three seconds and the
display will indicate 88:88 and activate all four annun-
ciators.

FIELD OPTION CHANGES

When  changes  are  made  the  connector  of  the  clock
must  be  grounded  to  the  soldering  iron  or  warranty 
may be void.

Serial Time Data:

 

To change from GMT to LT, remove

case and jumper LT.

Local Time:

 

To change from 12 hour to 24 hour format,

hold SEL in LT mode for 5 seconds till 12 HR or 24 HR 
flashes, then push CTL for desired format. Push SEL to 
exit set mode.

Flight Time:

 

To change from recording in hours, min-

utes  to  recording  in  hours,  tenths  and  hundredths,
remove case and jumper 99.

Battery Removal:

 

The battery and battery holder may

be removed permanently if the aircraft battery is con-
nected to the Keep Alive input (Pin 9). No changes in
the clock are required.

Remote Time Display:

 

Additional time displays can be

driven by the M877 clock. Only two wires carry the time
information to the remote display. The remote displays
have  independent  automatic  dimming.  Either  GMT  or
LT may be displayed. Remote display units are available
from Davtron, Inc.

STANDARD AND 

OPTIONAL FEATURES

Local Time

 

12 or 24 hour format.

Flight Time

 

in standard format of hours, minutes,

(99:59)  or  optional  format  of  hours,  tenths  and  hun-
dredths up to 99:99.

Flight  Time  Settable  Alarm

 

when  FT

reaches  programmed  alarm  time  the  display  flashes
and the external alarm output is activated.

Elapsed Time Count Up

 

counts in minutes

and  seconds  up  to  59  minutes  and  59  seconds  and
then changes to hours and minutes up tp 99 hours and
59 minutes.

Elapsed Time Count Down

 

may be set to

count  down  anywhere  from  one  second  to  59  minutes
and 59 seconds.

Elapsed  Time  Alarm

 

when the count down 

time entered reaches zero the display flashes and the
external alarm output is activated. (Optional)

Serial Time

 

output standard is GMT. (Local Time

Optional)

Voltage  Input

 

is  28  Volts  to  14  Volt.

Battery

 

is  a  longlife  AA  alkaline  cell.  The  rec-

ommended  change  interval  is  two  year.  The  clock
is  available  without  battery  from  the  factory.  Keep
Alive  (Pin  9)  must  then  be  connected  to  aircraft
battery. Remove AA battery if pin 9 is used.

Note

 

Battery  can  be  easily  removed  and  replaced

without  removing  clock  from  aircraft.  Battery  holder  is
polarity marked with red end positive (+).

Greenwich Mean Time

Local Time

Flight Time

Elapsed Time