DAVIS WeatherLink APRS Addendum Download Page 6

 

6

Streaming Data Logger Functionality & 
Troubleshooting 

 
The APRS streaming data logger compiles a character string consisting of 
the following: 

 
ASCII character “@”, 
The date and time on a 24 hour clock in the following format:  Day of 
Month, Hour, Minute, where each value is a 2 digit number. 
Lower case “z”, 
Latitude/longitude “position” string: 4903.50N/07201.75W_. 
Scalar average wind direction (in degrees) over one minute 
(reported as 000 if the average wind speed is zero); 
Forward slash “/”, 
Sustained one-minute wind speed (in mph); 
Lower case “g”, 
Gust (peak wind speed in mph in the last 5 minutes); 
Lower case “t”, 
Temperature (in degrees Fahrenheit). Temperatures below zero are 
expressed as -01 to -99; 
Lower case “r”, 
Rainfall (in hundredths of an inch) in the last hour, 
Lower case “p”, 
Rainfall (in hundredths of an inch) in the last 24 hours, 
Upper case “P”, 
Rainfall (in hundredths of an inch) since midnight, 
Lower case “h”, 
Humidity (in %. 00 = 100%), omitted if missing; 
Lower case “b”, 
Barometric pressure (in tenths of millibars/tenths of hPa), omitted if 
missing; 
The letter “L”, (upper case if solar radiation is below 1000, lower 
case if solar radiation is between 1000 and 1999), omitted if 
missing, 
Solar Radiation (in watts per square meter) last 3 digits (see above), 
omitted if missing, 
The following character string inside the quotes (including the 
leading period):  “.DsVP“.  This will indicate that a Davis Vantage 
Pro is sending the APRS data packet with its own proprietary 
device. 
Carriage Return character 
Line Feed character 

 

Upon powering up the console, the data logger will report rain over the last 
hour and the last 24 hour rain initially as zero and any cumulative rainfall 
after power up for the first hour and first 24 hours, respectively.  Also, if data 

Summary of Contents for WeatherLink APRS

Page 1: ...ta packets Computer running any version of Windows with at least 3 MB free of RAM and 512 KB of free hard disk space Please refer to the WeatherLink Getting Started Guide page 7 serial Port Installati...

Page 2: ...ity from the Start Menu under the WeatherLink directory Finding the Correct Serial Port The configuration software includes a procedure for locating the serial port to which your streaming data logger...

Page 3: ...ally set the com port and baud rate Consult your TNC modem and Ham Radio documentation to determine how to configure your streaming data logger to communicate APRS data to your Ham Radio Logger Type T...

Page 4: ...your Ham Radio The default value is 9600 This is also the recommended maximum value that you should set Transmission Rate Use this setting to determine how often to send APRS data packets Initially yo...

Page 5: ...5 Default Press this button to restore the data entries to their default values You must still hit OK to save the settings in the data logger...

Page 6: ...p Rainfall in hundredths of an inch in the last 24 hours Upper case P Rainfall in hundredths of an inch since midnight Lower case h Humidity in 00 100 omitted if missing Lower case b Barometric pressu...

Page 7: ...problems such as disconnected sensors or poor reception data may not be reported Hourly and last 24 hour rain will resume reporting totals normally after the data logger streaming function is interru...

Page 8: ...8 Product Number 06540 Davis Instruments Part Number 07395 218 WeatherLink for APRS Rev A Addendum 1 26 05...

Reviews: