background image

9

Wireless Vantage Pro2

S e n s o r   C h a r t s

P a c k a g e   D i m e n s i o n s

Product #

Package Dimensions

(Length x Width x Height)

Package Weight

UPC Codes

6152

6152EU
6152UK

17.0" x 11.0" x 13.0" 

(410 mm x 264 mm x 330 mm)

12.8 lbs. (5.8 kg)

011698 00229 0
011698 00347 1
011698 00348 8

6162

6162EU
6162UK

13.3 lbs. (6.0 kg)

011698 00306 8
011698 00307 5
001698 00308 2

6153

6153EU
6153UK

15.0" x 13.0" x 24.0" 

(378 mm x 327 mm x 594 mm)

12.8 lbs. (5.8 kg)

011698 00335 8
011698 00336 5
001698 00337 2

6163

6163EU
6163UK

13.3 lbs. (6.0 kg)

011698 00341 9
011698 00342 6
001698 00342 3

Temperature Accuracy

0.0

1.0

2.0

3.0

4.0

5.0

-40

-20

0

20

40

60

80

100

120

140

Temperature (°F)

Temperature Accuracy

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

-40

-30

-20

-10

0

10

20

30

40

50

60

Temperature (°C)

Accuracy (°F)

Accuracy (°C)

Figure 1. Temperature Accuracy

Rain Rate Resolution

Low Range 

Resolution (in.)

10.0

1.00

0.10

0.01

0     1     2     3     4     5     6    7     8     9    10   11   12   13   14   15   16   17   18   19   20 

Rain Rate (in/hr.)

Rain Rate Resolution

Full Range 

Resolution (in.)

100.00

10.00

1.00

0.10

0.01

0     1     2     3     4     5     6    7     8     9    10   11   12   13   14   15   16   17   18   19   20 

Rain Rate (in/hr.)

Figure 2. Low Range Rain Rate Resolution

Figure 3. Full Range Rain Rate Resolution

Summary of Contents for Vantage Pro2 Updater

Page 1: ...solar radiation induced temperature errors in the outside temperature sensor readings The Fan aspirated 6153 and 6163 combine passive shielding with a solar powered fan that draws outside air in over...

Page 2: ...rrent display data describes the current reading for each weather variable In most cases the variable lists the most recently updated reading or calculation Some current variable displays can be adjus...

Page 3: ...01 to 0 25 Hg 0 1 to 6 4 mm Hg 0 1 to 8 5 hPa mb Clock Resolution 1 minute Units Time 12 or 24 hour format user selectable Date US or International format user selectable Accuracy 8 seconds month Adju...

Page 4: ...lculations Daily Monthly Highs Alarm High Threshold from Instant Calculation Humidity Inside Relative Humidity sensor located in console Resolution and Units 1 Range 1 to 100 RH Accuracy 3 0 to 90 RH...

Page 5: ...f the bucket whichever is greater Update Interval 20 to 24 seconds Storm Determination Method 0 02 0 5 mm begins a storm event 24 hours without further accumulation ends a storm event Current Display...

Page 6: ...e Fig 1 Update Interval 1 minute Current Display Data Instant user adjustable offset available Current Graph Data Instant Reading Daily and Monthly High and Low Historical Graph Data Hourly Readings D...

Page 7: ...Highs Alarm High Threshold from Instant Reading Ultra Violet UV Radiation Dose requires UV sensor Resolution and Units 0 1 MEDs to 19 9 MEDs 1 MED above 19 9 MEDS Range 0 to 199 MEDs Accuracy 5 of da...

Page 8: ...kts 3 km h 1 m s or 5 whichever is greater Maximum Cable Length 240 73 m See note on page 1 Current Display Data Instant Current Graph Data Instant 10 minute and Hourly Average Hourly High Daily Mont...

Page 9: ...3UK 13 3 lbs 6 0 kg 011698 00341 9 011698 00342 6 001698 00342 3 Temperature Accuracy 0 0 1 0 2 0 3 0 4 0 5 0 40 20 0 20 40 60 80 100 120 140 Temperature F Temperature Accuracy 0 0 0 5 1 0 1 5 2 0 2 5...