25

 T

ABLE 

A-1: EPA S

KIN 

P

HOTOTYPES

T

ABLE

A-2: E

NVIRONMENT 

C

ANADA 

S

KIN 

T

YPES AND 

R

EACTION TO THE 

S

UN

.  

Developed by T. B. Fitzpatrick of the Harvard Medical School. More about the 
Fitzpatrick Skin Types is available in: Fitzpatrick TB. Editorial: the validity and 
practicality of sun-reactive skin types I through VI. Arch Dermatol 1988; 124:869-871

Skin Phototype

Skin color

Tanning & Sunburn history

1 - Never tans,
 always burns

Pale or milky white; 
alabaster

Develops red sunburn; painful 
swelling, skin peels

2 - Sometimes 
tans, usually burns

Very light brown; 
sometimes freckles

Usually burns, pinkish or red coloring 
appears;
can gradually develop light brown tan

3 - Usually tans,
sometimes burns

Light tan; brown, or 
olive;
distinctly pigmented

Rarely burns; shows moderately rapid 
tanning response

4 - Always tans;
rarely burns

Brown, dark brown, or 
black

Rarely burns; shows very rapid 
tanning response

Skin Type

Skin Color

History of Tanning & Sunburning

I

White

Always burns easily, never tans

II

White

Always burns easily, tans minimally

III

Light Brown

Burns moderately, tans gradually

IV

Moderate Brown

Burns minimally, tans well

V

Dark Brown

Burns rarely, tans profusely

VI

Black

Never burns, deep pigmentation

Summary of Contents for Vantage Pro2 Updater

Page 1: ...Vantage Pro2 Weather Envoy Manual For Vantage Pro2 Vantage Pro2 Plus and Vantage Vue Weather Stations Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisnet com...

Page 2: ...installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the...

Page 3: ...software and data logger the Weather Envoy allows you to view store plot analyze export share and print your weather data Contents Before continuing please be sure your Weather Envoy package includes...

Page 4: ...band Router with one free port An Always on connection to the Internet A high speed DSL or cable internet connection that maintains constant connection to the internet Local Connection Macintosh Compu...

Page 5: ...up or damage the logger The WeatherLink data logger must be installed before you install the batteries or plug in the AC power adapter Note Make sure the logger is plugged in firmly and completely 1 R...

Page 6: ...place Inserting the Serial USB or IP data logger into the Envoy 4 Rejoin the case halves making sure the data logger cable passes through the cable channel 5 Fasten using the three screws you removed...

Page 7: ...is Instruments Technical Support See Contacting Davis Technical Support on page 20 4 Replace the battery cover on the case Optional Connecting AC Power The operating battery power for a cabled Weather...

Page 8: ...ware Optional Adding an External Temperature Probe Wireless Envoy Only Your wireless Weather Envoy has a built in temperature humidity sensor as well as the barometer The temperature and humidity are...

Page 9: ...RJ jack on the Envoy Note Note It may take several minutes for the temperature reading to stabilize If the Envoy is mounted outside in a weather proof shelter you should thread the probe cable up thr...

Page 10: ...sight 1000 feet 300 m Under most conditions 200 400 feet 60 120 m Other range and transmission considerations include Range may be reduced by walls ceilings trees foliage a metal roof or other large m...

Page 11: ...7 64 2 2 to 2 7 mm drill bit 4 Drive the two 6 x 1 3 5 mm x 25 mm pan head self threading screws into the wall 5 Leave at least a 1 8 3 mm space between the wall and the heads of the screws 6 Slide t...

Page 12: ...eatherLink Online Help for additional setup instructions USB Connection Locate a free USB port on your computer and connect the USB connector of the 8 cable to the port and connect the Mini B connecto...

Page 13: ...imes occurring within one second of each other On power up the IP data logger will negotiate its connection with the router 6 Write down the Device ID and Key located on the side of the WeatherLinkIP...

Page 14: ...ata logger may have difficulty communicating with the computer Warning Do not use phone cable Our cable looks like a phone cable but it is wired differently Note The data logger does not require a con...

Page 15: ...n your CD ROM drive The install program should start automatically If the install program does not start select Run from the Start menu type D SETUP or the correct letter for your CD ROM drive and cli...

Page 16: ...e Set Transceiver dialog box displays 2 Select a Station Type for each of the possible 8 transmitter IDs channels the Envoy may be receiving See the WeatherLink Online Help System for more information...

Page 17: ...eep verifies the installation of the data logger If you do not hear two beeps contact Davis Instruments Technical Support 5 If you hear both beeps see Troubleshooting Serial Port Communication on page...

Page 18: ...p menu The Communications Port dialog box displays 4 Click Loopback The software searches all standard ports and displays the COM port number where the loopback connector is located The correct COM po...

Page 19: ...ug the cable back into the Envoy Open the WeatherLink software again Open the Communications Port dialog box Select USB if USB is not selected in the communications field and follow the prompts Click...

Page 20: ...r up you will hear two beeps 6 Check if the green light on the WeatherLink IP data logger is on If it is not on contact Technical Support 7 For Weatherlink com Wait five minutes Go to www weatherlink...

Page 21: ...at can I do The Vantage Pro2 system is smart enough to send only data it hasn t already sent to the computer So when you initiate a new download the program will retrieve the first record after the la...

Page 22: ...led in your weather station be sure check the Station Configuration in the Setup Menu and make sure the sensor has been selected Contacting Davis Technical Support If you have questions about the Envo...

Page 23: ...he temperature of liquids such as water Apparent Temperatures The Weather Envoy calculates four apparent temperature readings wind chill heat index the temperature humidity wind index THW Index and th...

Page 24: ...at the air can contain varies with air temperature and pressure Relative humidity takes into account these factors and offers a humidity reading which reflects the amount of water vapor in the air as...

Page 25: ...ayed Converting at display time reduces possible compounded rounding errors over time Four separate variables track rain totals rain storm daily rain monthly rain and yearly rain Rain rate calculation...

Page 26: ...ess the immune system The Weather Envoy can help analyze the changing levels of UV radiation and can advise of situations where exposure is particularly unacceptable CAUTION Be aware that the UV senso...

Page 27: ...2 Sometimes tans usually burns Very light brown sometimes freckles Usually burns pinkish or red coloring appears can gradually develop light brown tan 3 Usually tans sometimes burns Light tan brown o...

Page 28: ...opted by the World Meteorological Organization UV Index assigns a number between 0 and 16 to the current UV intensity The US EPA categorizes the Index values as shown below The lower the number the lo...

Page 29: ...ss sensor 6420 Leaf wetness provides an indication of whether the surface of foliage in the area of the sensor is wet or dry by indicating how wet the surface of the sensor is The leaf wetness reading...

Page 30: ...y Transmit Receive Frequency US Models 902 928 MHz FHSS Overseas Models 868 0 868 6 MHz FHSS ID Codes Available 8 Output Power 902 928 MHz FHSS FCC certified low power less than 8 mW no license requir...

Page 31: ...or slowly Steady or Falling rapidly or slowly Update Interval 1 minute Current Data Instant 15 min and Hourly Reading Daily Monthly High and Low Historical Data 15 min and Hourly Reading Daily Monthl...

Page 32: ...se Sunset Report F7 NOAA This Month F8 NOAA This Year Strip Chart Window ESC Halt Redraw Ctrl M Make Default Ctrl P Print Strip Chart F1 Context Sensitive Help F3 Zoom In F4 Zoom Out Plot Window ESC H...

Reviews: