DAVIS SONIC-ANEMO-DZP User Manual Download Page 6

SONIC-ANEMO-DZP 

© LCJ Capteurs 2016 – All rights reserved. 

Page 2 

5.

Recycling

LCJ Capteurs encourage recycling of all material when possible, following local regulations. You can find more 
details about recycling by contacting the local authorities in charge of Environment Protection in your country. 

European Union (and European Economic Area) only. 

These pictograms indicate that the product cannot be disposed of with waste, according to 
the European Directive DEEE (2002/96/CE), the Directive applying to batteries disposal 

(2006/66/CE) and local waste regulations following these directives. When a chemical toxicity pictogram is 
printed below this one, according to the Directive applying to batteries disposal, it means that Heavy Metals 
are present (Hg = mercury, Cd = cadmium, Pb = lead) in the battery at or above the applicable cut-off 
concentration specified in the Directive. This product must be given to a disposal centre, i.e. when you 
purchase a new similar product, or to a designated collection point for the recycling of waste electrical and 
electronic equipment (EEE). Wrong behaviour in disposal can have consequences on the environment and 
human health, because of the potentially hazardous substances generally associated to electric and electronic 
equipment. Your contribution to a correct disposal of this product will contribute to efficient use of natural 
resources.  

6.

Warranty

Your LCJ CAPTEURS product is warranted against manufacturing defects in materials and workmanship for a 
period of 24 months from the date of purchase. LCJ CAPTEURS will at its discretion, repair or replace faulty 
products free of charge at their premises. The warranty does not cover the installation labour and shipping 
costs of the faulty parts. A proof of purchase can be asked when processing the warranty claim by written. 
Once LCJ CAPTEURS approve the warranty claim, the sensor must be sent to their workshop address. LCJ 
Capteurs guaranties that each wind sensor is tested and calibrated before despatch.  
The warranty does not apply in the following cases:  
1. Damage resulting from misuse.
2. Improper installation or inappropriate conditions of operation.
3. If the product has been damaged, open or repaired by an unapproved agent.
4. Damage resulting from lightning, fire or any similar circumstances.
Warranty is void if operation, use, installation and technical service instructions have not been followed and if
a repair has been carried out without prior agreement.

7.

Product return

Contact your dealer prior to returning a product to LCJ CAPTEURS. A Return Merchandise Authorisation (RMA) 
must be issued and received before sending a product back.  

2. Introduction

A conventional Wind-vane Anemometer includes mechanical rotating parts. These parts are subject to wear 
and they represent sources of failure of the sensor. Our ultrasonic sensor has been designed to avoid this and 
to ensure reliable and stable operation. This Wind-vane-anemometer shows very stable results over a long 
term and with no maintenance.  

The sound (and ultrasound) is conveyed by the 
movement of the fluid in which it crosses. The electro 
acoustic transducers (1) communicate between 
themselves two by two using ultrasonic signals (2) to 
determine, following the orthogonal axes, the wave 
transit time differences induced by the air flow (3). The 

Summary of Contents for SONIC-ANEMO-DZP

Page 1: ...Ultrasonic wind vane anemometer compatible with Davis Equipment User Manual 07 11 2016 rev2 1 LCJ Capteurs ZA Le Chêne Ferré 44120 VERTOU France Tel 33 0 2 40 05 08 55 http www lcjcapteurs com contacts lcjcapteurs com ...

Page 2: ...tly developed Therefore the content of this manual can be amended without notice This manual does not create any legal bond between LCJ CAPTEURS and the customer of final user and LCJ CAPTEURS does not assume any responsibility for any damage and or injury resulting from the use of the product described in this manual Logos and images of Davis Instruments Corp are used with their kind permission D...

Page 3: ...ent rate of one per second gives you a clear vision of gusts Quick Installation 1 Connect the battery 4 Align your sensor with the tool supplied 2 Push the cap in place 3 Mount the sensor on a pole or a vertical surface 5 Connect the RJ11 connector to the interface module Photo credit DAVIS Instruments 6 Your sensor is ready to use Battery capacity The SONIC ANEMO DZP operates independently thanks...

Page 4: ...mballage 3 2 Déballage du produit 3 3 Sélection du meilleur emplacement 3 a Distance de dégagement 3 b Hauteur de montage 4 c Alignement du capteur 4 d Mode de fixation 4 4 Câblage 5 5 Alimentation 5 6 Connexion à l ISS Davis VP2 5 4 Configuration de la station DAVIS VP2 5 5 Mise en route 6 6 Maintenance 6 7 Remplacement de la batterie 6 8 Spécifications techniques 7 9 Déclaration de conformité 8 ...

Page 5: ...d to avoid damage and legal responsibility Follow all safety and use instructions regarding the product Follow all warning notices indicated in the product s use instructions The following instructions are meant to reduce all risk of personal injuries electric shock fire and damage of the equipment Read carefully and follow all instructions contained in this manual to avoid measures errors caused ...

Page 6: ...ill at its discretion repair or replace faulty products free of charge at their premises The warranty does not cover the installation labour and shipping costs of the faulty parts A proof of purchase can be asked when processing the warranty claim by written Once LCJ CAPTEURS approve the warranty claim the sensor must be sent to their workshop address LCJ Capteurs guaranties that each wind sensor ...

Page 7: ... through 9 degree steps This is Computer Controlled The sensor is aligned at 0 degrees of the air flow and then 40 measure points are completed with data saved for speed and angle You can read a typical test report here below The full document is available on our website 3 Installation 1 Checking the delivery Before opening the box check it carefully to spot any damage that can have occurred in tr...

Page 8: ...ded to install a sensor on a slanted roof These roofs generate upwards turbulences that will affect the sensor c Alignment of the sensor The sensor must be aligned to North An alignment tool is supplied for this purpose Clip the tool on the tube and slide it so that it snaps into the dedicated slots Do not tamper with the slots The tool must gently find its place Slightly loosen the 4 screws that ...

Page 9: ...e energy is stored in a LiFePO4 battery of 3 2 V 600 fitted in a 14500 box 6 Connection to the ISS Davis VP2 Follow the following instructions to connect the SONIC ANEMO DZP to a ISS Davis VP2 a Open the SIM box sliding the cover upwards b Disconnect the Solar Module if it is fitted Photos credit DAVIS Instruments 4 Configuration of the DAVIS VP2 The anemometer cups must be set to OTHER in the Set...

Page 10: ...olar module from time to time Warning Do not use alcohol base cleaning products Use a clean soft cloth clear water or a neutral cleaning product 7 Replacing the battery Choose a clean and dry location to change the battery a Disconnect the RJ11 from the SIM b Dismount the SONIC ANEMO DZP c Open the tube d Pull the battery s wires e Disconnect the battery f Spot the North mark on the battery s box ...

Page 11: ...nt the SONIC ANEMO DZP back in place q Connect the RJ11 on the SIM Note When purchasing the battery at LCJ Capteurs please mention the part number DZP_BATT Use only original battery with its wires and connectors Do not weld the wires directly on the battery 8 Technical specifications Technical documentation is available upon request ...

Page 12: ... anemoneter Conforms with the provisions of the following directives 1 Electromagnetic Compatibility 2004 108 CE 2 Low voltage 2006 95 CE This declaration of conformity is based on the product s compliance with the following harmonised standards 1 Electromagnetic Compatibility EN 61326 1 2006 2 Safety EN 61010 1 2001 Date of issue 14 10 2016 Signed by Christophe MICHEL Title ...