SONIC-ANEMO-DZP
Ultrasonic wind
-
vane
anemometer compatible with Davis Equipment
User Manual
07/11/2016 rev2.1
LCJ Capteurs
ZA Le Chêne Ferré
44120 VERTOU (France)
Tel: +33 (0)2 40 05 08 55
http://www.lcjcapteurs.com
contacts@
lcjcapteurs.com
Page 1: ...Ultrasonic wind vane anemometer compatible with Davis Equipment User Manual 07 11 2016 rev2 1 LCJ Capteurs ZA Le Chêne Ferré 44120 VERTOU France Tel 33 0 2 40 05 08 55 http www lcjcapteurs com contacts lcjcapteurs com ...
Page 2: ...tly developed Therefore the content of this manual can be amended without notice This manual does not create any legal bond between LCJ CAPTEURS and the customer of final user and LCJ CAPTEURS does not assume any responsibility for any damage and or injury resulting from the use of the product described in this manual Logos and images of Davis Instruments Corp are used with their kind permission D...
Page 3: ...ent rate of one per second gives you a clear vision of gusts Quick Installation 1 Connect the battery 4 Align your sensor with the tool supplied 2 Push the cap in place 3 Mount the sensor on a pole or a vertical surface 5 Connect the RJ11 connector to the interface module Photo credit DAVIS Instruments 6 Your sensor is ready to use Battery capacity The SONIC ANEMO DZP operates independently thanks...
Page 4: ...mballage 3 2 Déballage du produit 3 3 Sélection du meilleur emplacement 3 a Distance de dégagement 3 b Hauteur de montage 4 c Alignement du capteur 4 d Mode de fixation 4 4 Câblage 5 5 Alimentation 5 6 Connexion à l ISS Davis VP2 5 4 Configuration de la station DAVIS VP2 5 5 Mise en route 6 6 Maintenance 6 7 Remplacement de la batterie 6 8 Spécifications techniques 7 9 Déclaration de conformité 8 ...
Page 5: ...d to avoid damage and legal responsibility Follow all safety and use instructions regarding the product Follow all warning notices indicated in the product s use instructions The following instructions are meant to reduce all risk of personal injuries electric shock fire and damage of the equipment Read carefully and follow all instructions contained in this manual to avoid measures errors caused ...
Page 6: ...ill at its discretion repair or replace faulty products free of charge at their premises The warranty does not cover the installation labour and shipping costs of the faulty parts A proof of purchase can be asked when processing the warranty claim by written Once LCJ CAPTEURS approve the warranty claim the sensor must be sent to their workshop address LCJ Capteurs guaranties that each wind sensor ...
Page 7: ... through 9 degree steps This is Computer Controlled The sensor is aligned at 0 degrees of the air flow and then 40 measure points are completed with data saved for speed and angle You can read a typical test report here below The full document is available on our website 3 Installation 1 Checking the delivery Before opening the box check it carefully to spot any damage that can have occurred in tr...
Page 8: ...ded to install a sensor on a slanted roof These roofs generate upwards turbulences that will affect the sensor c Alignment of the sensor The sensor must be aligned to North An alignment tool is supplied for this purpose Clip the tool on the tube and slide it so that it snaps into the dedicated slots Do not tamper with the slots The tool must gently find its place Slightly loosen the 4 screws that ...
Page 9: ...e energy is stored in a LiFePO4 battery of 3 2 V 600 fitted in a 14500 box 6 Connection to the ISS Davis VP2 Follow the following instructions to connect the SONIC ANEMO DZP to a ISS Davis VP2 a Open the SIM box sliding the cover upwards b Disconnect the Solar Module if it is fitted Photos credit DAVIS Instruments 4 Configuration of the DAVIS VP2 The anemometer cups must be set to OTHER in the Set...
Page 10: ...olar module from time to time Warning Do not use alcohol base cleaning products Use a clean soft cloth clear water or a neutral cleaning product 7 Replacing the battery Choose a clean and dry location to change the battery a Disconnect the RJ11 from the SIM b Dismount the SONIC ANEMO DZP c Open the tube d Pull the battery s wires e Disconnect the battery f Spot the North mark on the battery s box ...
Page 11: ...nt the SONIC ANEMO DZP back in place q Connect the RJ11 on the SIM Note When purchasing the battery at LCJ Capteurs please mention the part number DZP_BATT Use only original battery with its wires and connectors Do not weld the wires directly on the battery 8 Technical specifications Technical documentation is available upon request ...
Page 12: ... anemoneter Conforms with the provisions of the following directives 1 Electromagnetic Compatibility 2004 108 CE 2 Low voltage 2006 95 CE This declaration of conformity is based on the product s compliance with the following harmonised standards 1 Electromagnetic Compatibility EN 61326 1 2006 2 Safety EN 61010 1 2001 Date of issue 14 10 2016 Signed by Christophe MICHEL Title ...