While the Wireless Weather Station is designed to provide years of trouble-free 
operation, occasional problems may arise.  If you experience a problem, please 
check the troubleshooters listed below before calling the factory.  If you still are  
unable to solve the problem, call the factory at (510) 732-7814 for assistance.  
Please do not return your unit for repair without prior authorization.

 

 

Console is receiving erratic data

 

Enable the Test Mode on the transmitter.  If two beeps or more are heard in 

a 2.5-second interval, then another Davis wireless system may be operating 
nearby on the same ID, or a cordless phone may be operating within 10 feet 
of the receiver.  Either try changing to a different ID code on both the 
receiver and the transmitter, or try moving the phone.  Reapply power to 
the console to activate the new ID code.

 

 

Console is not receiving any data  

 

The transmitter and the receiver may be too far apart, or something in their 

path may be interfering, such as foliage, furnishings or cordless phones.  
Enable Test Mode on the transmitter to see if it is receiving data. Try mov-
ing the receiver closer to the transmitter or vice versa; or eliminating possi-
ble path interferences.

 

 

Console is emitting beeps

 

If you hear 

 

single beeps

 

, flip dip switch #4 to turn off Test Mode in both the 

transmitter and receiver.

If you hear a 

 

double beep

 

, the SensorLink Receiver in the console is not 

receiving data.  This occurs when the receiver has not received data for 30 
minutes.  Try moving the receiver closer to the transmitter or vice versa; or 
eliminating possible path interferences.

If you hear a 

 

triple beep

 

, the transmitter is extremely low on power—replace 

battery immediately.

 

 

Data from the optional WeatherLink program shows temperature, humidity, or wind 

values that were constant over some period

 

The SensorLink Receiver in the console did not receive new data during 

this period and passed the last good data to the WeatherLink.  Try moving 
the receiver closer to the transmitter or vice versa; or eliminating possible 
path interferences.

 

 

Battery(ies) are not lasting the expected 6 months (for 1 battery) or 1 year (for 2 bat-

teries)

 

Make sure dip switch #4 in the transmitter is set to OFF to prevent the LED 

from flashing unnecessarily when not testing.   If you are using two batter-
ies, also make sure that both are fresh when installed.  

Summary of Contents for SensorLink

Page 1: ...splay console connects to the receiver One transmitter can send data to any number of Monitor II or Wizard III con soles providing the console contains an receiver The transmitter receiver communicate...

Page 2: ...the default setting unless you have another Davis wireless weather station operating nearby which you want to work separately from the new system The dip switch settings for the eight possible codes...

Page 3: ...wer up your console with dip switch 4 in the OFF position as shown above Silent Mode would be off and audible warnings would be on On the other hand if you were to power up your console with the dip s...

Page 4: ...200 feet 30 to 60 m As you position your console be aware of possible interference from cordless phones and other items To prevent interference maintain a distance of 10 feet between the console and t...

Page 5: ...6 x 1 screws Use two screws as pictured below when attaching to a stud Use three screws as pictured below in any other case 4 Insert the sensor cables in the appropriate jacks as shown below A B Base...

Page 6: ...hs of service Use two fresh lithium batteries to double life second is not provided Note This illustration as well as the following one shows the transmitter mounted inside a Davis Multi Purpose Shelt...

Page 7: ...nderside of the station console When you apply power to the console the console should beep three times within 20 seconds to indicate that the console and receiver are working properly or 4 times with...

Page 8: ...Note that some readings must be calibrated in order to read correctly calibration instructions are contained in the station manual If problems occur reading the outdoor sensors consult the troublesho...

Page 9: ...Reattach the console base The closed console with and without optional WeatherLink is displayed below A B SensorLink Receiver inside Console Base Power Adapter Weather Station Console 110 VAC Power Ou...

Page 10: ...see if it is receiving data Try mov ing the receiver closer to the transmitter or vice versa or eliminating possi ble path interferences Console is emitting beeps If you hear single beeps flip dip sw...

Page 11: ...e console SensorLink Transmitter Transmit frequency 916 5 MHz ID codes 8 user selectable License Low power less than 1 mW no license required Sensor connections Telephone modular for Anemometer Temp H...

Page 12: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc tions may cause harmful interference to radio communications However there...

Reviews: