Prepare the Sensor Transmitter
The illustration below shows the sensor interface inside the Sensor Transmitter.
Battery
Pull Tab
DIP Switches
Cable Clamp
Mount
Sensor
Cable
(Anemometer
Shown)
AC- Power
Adapter
Cable
(AC Model Only)
Square Black Grommets
SENSOR
SENSOR
INTERFACE
INTERFACE
MODULE
MODULE
UV
UV
SUN
SUN
RAIN
RAIN
WIND
WIND
TEMP
TEMP
HUM
HUM
+
-
Cable Clamp
Test LED
3-Volt
Lithium Battery
1. Remove the battery pull tab and make sure the battery is firmly seated in the battey
compartment.
2. AC-powered model only: Push the power cable up through the square black grommet
on the bottom right. Plug it into the power jack above the battery compartment.
3. Push the ends of the sensor cables up through the square black grommet of one of the
weather-resistant entrances for cables.
Tip:
You might find it easier to remove the grommet, thread the cable through it and then replace the
grommet.
4. Plug each sensor cable into the correct receptacle according to the label above each
receptacle. See “Installing Sensors” on page 7.
5. You may place a cable clamp over the cable (or two cables) between the grommet and
the receptacle. Secure the cable clamp to the shelter by threading the provided #6
screw through the washer, then cable clamp and then screwing it into the cable clamp